Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance - A cadaver study

被引:163
|
作者
Mirza, SK
Wiggins, GC
Kuntz, C
York, JE
Bellabarba, C
Knonodi, MA
Chapman, JR
Shaffrey, CI
机构
[1] Univ Washington, Harborview Med Ctr, Dept Orthoped & Sports Med, Seattle, WA 98195 USA
[2] Univ Washington, Dept Neurol Surg, Seattle, WA 98195 USA
[3] Univ Cincinnati, Dept Neurol Surg, Cincinnati, OH USA
[4] Loyola Univ, Dept Neurol Surg, Maywood, IL 60153 USA
关键词
computed tomography; FluoroNav; fluoroscopy; image-guided surgery; radiation exposure; spinal fixation; spinal instrumentation; StealthStation; thoracic pedicle screws; thoracic spine fixation;
D O I
10.1097/00007632-200302150-00018
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A surgical simulation study in human cadaver spine specimens was conducted to evaluate the accuracy of thoracic vertebral body screw placement using four different intraoperative imaging techniques. Objective. To compare standard fluoroscopy, fluoroscopy-based image guidance with two different referencing methods, and computed tomography-based image guidance by the measuring the time required for screw placement, the radiation exposure to specimen and surgeon, and the accuracy of screw position in the thoracic spine. Summary of Background Data. Image guidance provides additional anatomic information to the surgeon and may improve safety of technically difficult surgical procedures. The placement of screws in the thoracic spine is a technically demanding procedure in which inaccurate screw positioning places the spinal cord, nerve roots, and paraspinal structures such as the aorta and pleural space at risk for injury. Image-guided surgery may improve the accuracy of thoracic screw placement. Methods. Using four different intraoperative imaging methods, two experienced surgeons placed 337 vertebral body screws through the pedicles of thoracic vertebrate in 20 human cadaver thoracic spine specimens. The specimens than were examined with radiographs, computed tomography, and anatomic dissection to determine screw position. Measurements included procedure, setup and screw insertion time, radiation exposure to the specimen, the surgeon's hand, the surgeon's body, frequency, directional, and magnitude of screw perforation through the cortical margins of thoracic vertebrate. Results. As compared with surgery using standard fluoroscopy, fluoroscopy-based image guidance that uses multiple reference marks and computed tomography-based image guidance improves the accuracy of thoracic vertebral body screws placement and the specimen radiation exposure. Exposure to radiation is minimal at the surgeon's hand level and dependent on surgical technique at the surgeon's hand level. Screw perforation occurs most frequently in the lateral direction. Conclusions. Fluoroscopy-based image guidance that uses only a single reference marker for the entire thoracic spine is highly inaccurate and unsafe. Systems with registration based on the instrumented vertebrate provide more accurate placement of thoracic vertebral body screws than standard fluoroscopy, but expose the patient to more radiation and require more time for screw insertion.
引用
收藏
页码:402 / 413
页数:12
相关论文
共 40 条
  • [31] Treatment of vertebral body compression fractures using percutaneous kyphoplasty guided by a combination of computed tomography and C-arm fluoroscopy with finger-touch guidance to determine the needle entry point
    Wang, G. Y.
    Zhang, C. C.
    Ren, K.
    Zhang, P. P.
    Liu, C. H.
    Zheng, Z. A.
    Chen, Y.
    Fang, R.
    GENETICS AND MOLECULAR RESEARCH, 2015, 14 (01) : 1546 - 1556
  • [32] Accuracy of Image-Guided Pedicle Screw Placement Using Intraoperative Computed Tomography-Based Navigation With Automated Referencing, Part I: Cervicothoracic Spine
    Scheufler, Kai-Michael
    Franke, Joerg
    Eckardt, Anke
    Dohmen, Hildegard
    NEUROSURGERY, 2011, 69 (04) : 782 - 795
  • [33] Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance by Eric W. Nottmeier and Andrew B. Foy
    J. J. Verlaan
    European Spine Journal, 2008, 17 : 616 - 617
  • [34] Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance by Eric W. Nottmeier and Andrew B. Foy
    Verlaan, J. J.
    EUROPEAN SPINE JOURNAL, 2008, 17 (04) : 616 - 617
  • [35] Accuracy of Image-Guided Pedicle Screw Placement Using Intraoperative Computed Tomography-Based Navigation With Automated Referencing. Part II: Thoracolumbar Spine
    Scheufler, Kai-Michael
    Franke, Joerg
    Eckardt, Anke
    Dohmen, Hildegard
    NEUROSURGERY, 2011, 69 (06) : 1307 - 1316
  • [36] Accuracy of Image-Guided Pedicle Screw Placement Using Intraoperative Computed Tomography-Based Navigation With Automated Referencing, Part I: Cervicothoracic Spine COMMENTS
    Welch, William C.
    Heary, Robert F.
    NEUROSURGERY, 2011, 69 (04) : 795 - 795
  • [37] Pedicle screw placement accuracy using ultra-low radiation imaging with image enhancement versus conventional fluoroscopy in minimally invasive transforaminal lumbar interbody fusion: an internally randomized controlled trial
    Nayar, Gautam
    Blizzard, Daniel J.
    Wang, Timothy Y.
    Cook, Steven
    Back, Adam G.
    Vincent, David
    Karikari, Isaac O.
    JOURNAL OF NEUROSURGERY-SPINE, 2018, 28 (02) : 186 - 193
  • [38] A Pilot Study on Spine Stereotactic Body Radiation Therapy Residual Setup Errors and Intrafraction Motion Using Stereotactic X-ray Image Guidance Verification System
    Yamoah, K.
    Siglin, J.
    Shi, W.
    Werner-Wasik, M.
    Andrews, D.
    Dicker, A.
    Bar-Ad, V.
    Liu, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S265 - S266
  • [39] Real-Time 3D Image Guidance Using a Standard LINAC: Measured Motion, Accuracy, and Precision of the First Prospective Clinical Trial of Kilovoltage Intrafraction Monitoring-Guided Gating for Prostate Cancer Radiation Therapy
    Keall, Paul J.
    Ng, Jin Aun
    Juneja, Prabhjot
    O'Brien, Ricky T.
    Huang, Chen-Yu
    Colvill, Emma
    Caillet, Vincent
    Simpson, Emma
    Poulsen, Per R.
    Kneebone, Andrew
    Eade, Thomas
    Booth, Jeremy T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 94 (05): : 1015 - 1021
  • [40] A MULTI-CENTRE RANDOMISED CONTROLLED TRIAL ASSESSING WHETHER MRI-TARGETED BIOPSY IS NON-INFERIOR TO STANDARD TRANS-RECTAL ULTRASOUND GUIDED BIOPSY FOR THE DIAGNOSIS OF CLINICALLY SIGNIFICANT PROSTATE CANCER IN MEN WITHOUT PRIOR BIOPSY - THE PRECISION STUDY: PROSTATE EVALUATION FOR CLINICALLY IMPORTANT DISEASE, SAMPLING USING IMAGE-GUIDANCE OR NOT? (NCT02380027)
    Kasivisvanathan, Veeru
    Rannikko, Antti
    Borghi, Marcelo
    Panebianco, Valeria
    Mynderse, Lance
    Vaarala, Markku
    Briganti, Alberto
    Budaeus, Lars
    Hellawell, Giles
    Hindley, Richard
    Roobol, Monique
    Eggener, Scott
    Ghei, Maneesh
    Villers, Arnauld
    Bladou, Franck
    Villeirs, Geert
    Virdi, Jaspal
    Boxler, Silvan
    Robert, Gregoire
    Singh, Paras
    Venderink, Wulphert
    Hadaschik, Boris
    Ruffion, Alain
    Hu, Jim
    Margolis, Daniel
    Crouzet, Sebastien
    Klotz, Laurence
    Taneja, Samir
    Pinto, Peter
    Gill, Inderbir
    Allen, Clare
    Giganti, Francesco
    Freeman, Alex
    Morris, Steve
    Punwani, Shonit
    Williams, Norman
    Brew-Graves, Chris
    Takwoingi, Yemisi
    Emberton, Mark
    Moore, Caroline
    JOURNAL OF UROLOGY, 2018, 199 (04): : E1033 - E1033