Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance - A cadaver study

被引:163
|
作者
Mirza, SK
Wiggins, GC
Kuntz, C
York, JE
Bellabarba, C
Knonodi, MA
Chapman, JR
Shaffrey, CI
机构
[1] Univ Washington, Harborview Med Ctr, Dept Orthoped & Sports Med, Seattle, WA 98195 USA
[2] Univ Washington, Dept Neurol Surg, Seattle, WA 98195 USA
[3] Univ Cincinnati, Dept Neurol Surg, Cincinnati, OH USA
[4] Loyola Univ, Dept Neurol Surg, Maywood, IL 60153 USA
关键词
computed tomography; FluoroNav; fluoroscopy; image-guided surgery; radiation exposure; spinal fixation; spinal instrumentation; StealthStation; thoracic pedicle screws; thoracic spine fixation;
D O I
10.1097/00007632-200302150-00018
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A surgical simulation study in human cadaver spine specimens was conducted to evaluate the accuracy of thoracic vertebral body screw placement using four different intraoperative imaging techniques. Objective. To compare standard fluoroscopy, fluoroscopy-based image guidance with two different referencing methods, and computed tomography-based image guidance by the measuring the time required for screw placement, the radiation exposure to specimen and surgeon, and the accuracy of screw position in the thoracic spine. Summary of Background Data. Image guidance provides additional anatomic information to the surgeon and may improve safety of technically difficult surgical procedures. The placement of screws in the thoracic spine is a technically demanding procedure in which inaccurate screw positioning places the spinal cord, nerve roots, and paraspinal structures such as the aorta and pleural space at risk for injury. Image-guided surgery may improve the accuracy of thoracic screw placement. Methods. Using four different intraoperative imaging methods, two experienced surgeons placed 337 vertebral body screws through the pedicles of thoracic vertebrate in 20 human cadaver thoracic spine specimens. The specimens than were examined with radiographs, computed tomography, and anatomic dissection to determine screw position. Measurements included procedure, setup and screw insertion time, radiation exposure to the specimen, the surgeon's hand, the surgeon's body, frequency, directional, and magnitude of screw perforation through the cortical margins of thoracic vertebrate. Results. As compared with surgery using standard fluoroscopy, fluoroscopy-based image guidance that uses multiple reference marks and computed tomography-based image guidance improves the accuracy of thoracic vertebral body screws placement and the specimen radiation exposure. Exposure to radiation is minimal at the surgeon's hand level and dependent on surgical technique at the surgeon's hand level. Screw perforation occurs most frequently in the lateral direction. Conclusions. Fluoroscopy-based image guidance that uses only a single reference marker for the entire thoracic spine is highly inaccurate and unsafe. Systems with registration based on the instrumented vertebrate provide more accurate placement of thoracic vertebral body screws than standard fluoroscopy, but expose the patient to more radiation and require more time for screw insertion.
引用
收藏
页码:402 / 413
页数:12
相关论文
共 40 条
  • [1] Accuracy of screw placement during vertebral body tethering using fluoroscopic guidance and anatomic landmarks
    Neal, Kevin M.
    Krombholz, Kylie
    Doshi, Mona
    SPINE DEFORMITY, 2025, 13 (01) : 153 - 158
  • [2] Accuracy of upper thoracic pedicle screw placement using three-dimensional image guidance
    Bledsoe, Jonathan M.
    Fenton, Doug
    Fogelson, Jeremy L.
    Nottmeier, Eric W.
    SPINE JOURNAL, 2009, 9 (10): : 817 - 821
  • [3] The accuracy of pedicle screw placement using intraoperative image guidance systems
    Mason, Alexander
    Paulsen, Renee
    Babuska, Jason M.
    Rajpal, Sharad
    Burneikiene, Sigita
    Nelson, E. Lee
    Villavicencio, Alan T.
    JOURNAL OF NEUROSURGERY-SPINE, 2014, 20 (02) : 196 - 203
  • [4] Pedicle screw insertion: computed tomography versus fluoroscopic image guidance
    Tsai-Sheng Fu
    Chak-Bor Wong
    Tsung-Ting Tsai
    Yen-Chiu Liang
    Lih-Huei Chen
    Wen-Jer Chen
    International Orthopaedics, 2008, 32 : 517 - 521
  • [5] Pedicle screw insertion: computed tomography versus fluoroscopic image guidance
    Fu, Tsai-Sheng
    Wong, Chak-Bor
    Tsai, Tsung-Ting
    Liang, Yen-Chiu
    Chen, Lih-Huei
    Chen, Wen-Jer
    INTERNATIONAL ORTHOPAEDICS, 2008, 32 (04) : 517 - 521
  • [6] Thoracic pedicle screw placement - Analysis using anatomical landmarks without image guidance
    Elliott, Michael J.
    Slakey, C. D. R. Joseph B.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2007, 27 (05) : 582 - 586
  • [7] Screw Placement and Osteoplasty Under Computed Tomographic–Fluoroscopic Guidance in a Case of Advanced Metastatic Destruction of the Iliosacral Joint
    Christoph Gregor Trumm
    Bianca Rubenbauer
    Stefan Piltz
    Maximilian F. Reiser
    Ralf-Thorsten Hoffmann
    CardioVascular and Interventional Radiology, 2011, 34 : 288 - 293
  • [8] Screw Placement and Osteoplasty Under Computed Tomographic-Fluoroscopic Guidance in a Case of Advanced Metastatic Destruction of the Iliosacral Joint
    Trumm, Christoph Gregor
    Rubenbauer, Bianca
    Piltz, Stefan
    Reiser, Maximilian F.
    Hoffmann, Ralf-Thorsten
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 : S288 - S293
  • [9] Comparison of Cervical Pedicle Screw Placement Accuracy With Robotic Guidance System Versus Image Guidance System Using Propensity Score Matching
    Yamamoto, Yuki
    Fujishiro, Takashi
    Hirai, Hiromichi
    Hayama, Sachio
    Nakaya, Yoshiharu
    Usami, Yoshitada
    Neo, Masashi
    CLINICAL SPINE SURGERY, 2024, 37 (10): : E424 - E432
  • [10] Accuracy of thoracolumbar transpedicular and vertebral body percutaneous screw placement: coupling the Rosa® Spine robot with intraoperative flat-panel CT guidance—a cadaver study
    Lefranc M.
    Peltier J.
    Journal of Robotic Surgery, 2015, 9 (4) : 331 - 338