Performance investigation of salt gradient cylindrical solar pond integrated and nonintegrated with evacuated tube solar collectors

被引:5
|
作者
Atiz, Ayhan [1 ]
Bozkurt, Ismail [2 ]
Karakilcik, Mehmet [3 ]
机构
[1] Alanya Alaaddin Keykubat Univ, Dept Math & Sci Educ, Fac Educ, Antalya, Turkey
[2] Adiyaman Univ, Dept Mech Engn, Fac Engn, Adiyaman, Turkey
[3] Univ Cukurova, Fac Sci & Letters, Dept Phys, TR-01330 Adana, Turkey
关键词
energy; exergy; heat storage; solar collector; solar pond; HEAT EXTRACTION; ENERGY; EXERGY;
D O I
10.1002/er.4304
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, the energetic and exergetic efficiencies of a salt gradient cylindrical solar pond (SGCSP) that integrated and nonintegrated evacuated tube solar collectors (ETSCs) are investigated to improve daily heat preservation performance of the heat storage zone (HSZ). The integrated system is consisted of an SGCSP and four ETSCs. The SGCSP has a surface area of 2 m(2), a depth of 1.65 m, salty water layers at different densities, and HSZ in which the cylindrical serpentine type heat exchanger (CSHE) is located. Thus, the daily effects of the heat storage performance of both the ETSCs and the SGCSP in the winter season was determined experimentally. The analysis of the data regarding the efficiencies of the system is investigated separately by means of experimental studies where the SGCSP is integrated and nonintegrated with the ETSCs. The number of ETSCs integrated with SGCSP is increased to 1, 2, 3, and 4, respectively, and each of the five different experimental systems is performed separately. The temperature distributions of the integrated system are measured by a data acquisition system on 11 different points per hour. The efficiencies are calculated using the data obtained from these studies. Consequently, the energetic and exergetic efficiencies of the SGCSP are obtained without collectors as 10.4% and 4.3% and with one collector as 12.83% and 6.15%, with two collectors 14.88% and 8.25%, with three collectors 16% and 9.35%, and finally with four collectors 16.94% and 10.3%, respectively. Furthermore, the theoretical efficiencies are found to be consistent with the experimental results obtained by increasing the collector numbers.
引用
收藏
页码:6243 / 6255
页数:13
相关论文
共 50 条
  • [21] Research on thermal performance and flow resistance of evacuated tube solar air collectors
    Zeng, D. (zengdongqi6@163.com), 1600, Science Press (35):
  • [22] The research on thermal and economic performance of solar desalination system with evacuated tube collectors
    Liu, Xiaohua
    Chen, Wenbo
    Shen, Shengqiang
    Gu, Ming
    Cao, Guojian
    DESALINATION AND WATER TREATMENT, 2013, 51 (19-21) : 3728 - 3734
  • [23] TRANSIENT PERFORMANCE OF EVACUATED TUBULAR SOLAR COLLECTORS
    BEHRENDORFF, MJ
    TANNER, RI
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (04): : 326 - 332
  • [24] PERFORMANCE OF AN EVACUATED GLASS TUBE SOLAR COLLECTOR INTEGRATED WITH A SOLAR HEATING SYSTEM.
    Ward, John C.
    Ward, Dan S.
    1600, Am Sect of Int Sol Energy Soc, Inc, Univ of DelNewark (2 .):
  • [25] SATURATED SALT GRADIENT SOLAR POND
    TSINOBER, A
    HAREL, Z
    MELAMED, A
    PHYSICOCHEMICAL HYDRODYNAMICS, 1985, 6 (5-6): : 829 - 840
  • [26] PERFORMANCE OF A LARGE, SALT-GRADIENT SOLAR POND.
    Wittenberg, Layton J.
    Harris, Marc J.
    Proceedings of the Intersociety Energy Conversion Engineering Conference, 1979, 1 : 49 - 52
  • [27] THERMAL PERFORMANCE OF A PROTOTYPE EXPERIMENTAL SOLAR POND WITH SALT GRADIENT
    Bezir, Nalan C.
    Sencan, Arzu
    Ozek, Nuri
    Yakut, Ali Kemal
    Kayali, Refik
    Dikmen, Erkan
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2008, 23 (02): : 405 - 411
  • [28] MATHEMATICAL MODELLING OF SALT GRADIENT SOLAR POND PERFORMANCE.
    Ali, H.M.
    1600, (10):
  • [29] PERFORMANCE OF A SALT-GRADIENT SOLAR POND FOR POWER PRODUCTION
    HAWAS, MM
    ELASFOURI, AS
    ENERGY CONVERSION AND MANAGEMENT, 1985, 25 (03) : 323 - 330