Recalibration of a stereoscopic camera system for in-flight wing deformation measurements

被引:16
|
作者
Kirmse, Tania [1 ]
机构
[1] Inst Aerodynam & Flow Technol, DLR Gottingen, Bunsenstr 10, D-37073 Gottingen, Germany
基金
欧盟第七框架计划;
关键词
camera calibration; stereo photogrammetry; deformation measurement; IMAGE REGISTRATION; SELF-CALIBRATION;
D O I
10.1088/0957-0233/27/5/054001
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A decalibration of a stereoscopic camera system caused by slight movements of the cameras can influence the accuracy of the measured 3D positions significantly. Especially for large scale in-flight applications this is difficult to avoid, e.g. due to the high loads and the vibration level occurring during dynamic flight manoeuvres. Thus a practicable approach for a correction of the results by a recalibration of the camera system is necessary. The image pattern correlation technique (IPCT) delivers large area surface results which enables the assessment of its triangulation error in detail as a measure for the quality of the results. The objective of the presented recalibration is a minimisation of the overall triangulation error by a correction of the external camera parameters. The criteria to assess the reliability of the 3D-surface results and the deformation results derived from are described as well as the limitations of the method. A wing deformation measurement on a VUT100 Cobra aeroplane by means of stereoscopic IPCT was used as a test case to demonstrate the applicability of the recalibration method on real flight test data.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] ISGRI CdTe camera in-flight behavior
    Limousin, O
    Claret, A
    Delagnes, E
    Laurent, P
    Lebrun, F
    Lugiez, F
    Sauvageon, A
    Terrier, R
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3555 - 3559
  • [22] In-flight calibration of the Dawn Framing Camera
    Schroeder, S. E.
    Maue, T.
    Marques, P. Gutierrez
    Mottola, S.
    Aye, K. M.
    Sierks, H.
    Keller, H. U.
    Nathues, A.
    ICARUS, 2013, 226 (02) : 1304 - 1317
  • [23] In-flight validation and routine measurements
    Beck, P
    Bartlett, D
    O'Brien, K
    Schrewe, UJ
    RADIATION PROTECTION DOSIMETRY, 1999, 86 (04) : 303 - 308
  • [24] Numerical investigation of the error caused by the aero-optical environment around an in-flight wing in optically measuring the wing deformation
    Liu, Yan
    Yuan, Yingtao
    Guo, Xiang
    Suo, Tao
    Li, Yulong
    Yu, Qifeng
    AEROSPACE SCIENCE AND TECHNOLOGY, 2020, 98
  • [25] Dynamics and Control of In-Flight Wing Tip Docking
    Cooper, John R.
    Rothhaar, Paul M.
    JOURNAL OF GUIDANCE CONTROL AND DYNAMICS, 2018, 41 (11) : 2327 - 2337
  • [26] Application of high-speed videography for in-flight deformation measurements of aircraft propellers
    Stasicki, Boleslaw
    Boden, Fritz
    28TH INTERNATIONAL CONGRESS ON HIGH-SPEED IMAGING AND PHOTONICS, 2009, 7126
  • [27] Aircraft health and usage monitoring system for in-flight strain measurement of a wing structure
    Kim, Jin-Hyuk
    Park, Yurim
    Kim, Yoon-Young
    Shrestha, Pratik
    Kim, Chun-Gon
    SMART MATERIALS AND STRUCTURES, 2015, 24 (10)
  • [28] A fast response probe system for in-flight measurements of atmospheric turbulence
    Lemonis, G
    Schmücker, M
    Struck, H
    AEROSPACE SCIENCE AND TECHNOLOGY, 2002, 6 (03) : 233 - 243
  • [29] LDA system for in-flight local velocity measurements on airplane wings
    Becker, S
    Durst, F
    Lienhart, H
    ICIASF'99: INTERNATIONAL CONGRESS ON INSTRUMENTATION IN AEROSPACE SIMULATION FACILITIES, RECORD, 1999, : 251 - 257
  • [30] In-flight performance of the Advanced Camera for Surveys CCDS
    Clampin, M
    Sirianni, M
    Hartig, GF
    Ford, HC
    Illingworth, GD
    Burmester, B
    Koldewynd, W
    Martel, AR
    Riess, A
    Schrein, RJ
    Sullivan, PC
    SCIENTIFIC DETECTORS FOR ASTRONOMY: THE BEGINNING OF A NEW ERA, 2004, 300 : 555 - 564