Nafion coated flexible bismuth sensor for trace lead and cadmium determination

被引:9
|
作者
Wang, Li [1 ]
Jing, Gaoshan [1 ]
Cui, Tianhong [2 ]
机构
[1] Tsinghua Univ, Dept Precis Instrument, State Key Lab Precis Measurement Technol & Instru, Beijing 100084, Peoples R China
[2] Univ Minnesota, Dept Mech Engn, 111 Church St SE, Minneapolis, MN 55455 USA
来源
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS | 2018年 / 24卷 / 09期
关键词
ANODIC-STRIPPING VOLTAMMETRY; GLASSY-CARBON ELECTRODES; HEAVY-METAL IONS; FILM ELECTRODES; WATER; SAMPLES; BLOOD;
D O I
10.1007/s00542-018-3822-5
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper reports a low-cost and highly sensitive flexible sensor for the determination of lead and cadmium in tap and lake water. This sensor achieved low detection limits and high performance by decorating cation-exchanging resin and in situ deposited bismuth on the working electrode. In situ deposited bismuth film was much easier to fabricate and formed a highly porous 3-dimensional structure, which provided more surface area for the reaction of the target ions. The cation-exchanging Nafion film can help reduce the interference caused by surface active compounds and enhance the pre-concentration of lead and cadmium at the same time. Flexible polypropylene film was chosen as the substrate to reduce the cost and expand the sensor's applications. Finally, the detection limits were 1.68 ppb for Pb and 1.24 ppb for Cd at the deposition time of 300 s. Particularly, this sensor revealed good linearity (R-2 = 0.993) at a wide range of 10-500 ppb for cadmium in tap water environment. The proposed sensor was successfully applied to lead and cadmium determination in environmental water samples and the results were in good agreement with those from a standard procedure.
引用
收藏
页码:3697 / 3704
页数:8
相关论文
共 50 条
  • [21] Determination of Trace Cadmium and Lead in Water Based on Graphene-modified Platinum Electrode Sensor
    Tang Feng-Jie
    Zhang Feng
    Jin Qing-Hui
    Zhao Jian-Long
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (02) : 278 - 282
  • [22] BISMUTH-ANTIMONY FILM ELECTRODE FOR STRIPPING VOLTAMMETRIC DETERMINATION OF TRACE CADMIUM AND LEAD IN THAI RICE WINE
    Siriangkhawut, Watsaka
    Ponhong, Kraingkrai
    Chantiratikul, Piyanete
    Mayotha, Parita
    QUIMICA NOVA, 2023, 46 (07): : 718 - 723
  • [23] DETERMINATION OF TRACES OF BISMUTH COPPER AND LEAD IN CADMIUM BY PULSE POLAROGRAPHY
    TEMMERMAN, E
    VERBEEK, F
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1966, 12 (02) : 158 - +
  • [24] A SPECTROPOLARIMETRIC TITRIMETRIC METHOD FOR DETERMINATION OF CADMIUM, MERCURY, LEAD AND BISMUTH
    PALMA, RJ
    PEARSON, KH
    ANALYTICA CHIMICA ACTA, 1970, 49 (03) : 497 - &
  • [25] A sensitive electrochemical analysis for cadmium and lead based on Nafion-Bismuth film in a water sample
    Albalawi, Ibtihaj
    Hogan, Anna
    Alatawi, Hanan
    Moore, Eric
    SENSING AND BIO-SENSING RESEARCH, 2021, 34
  • [26] Construction of Pencil Graphite Electrode Modified with Nafion, MWCNT, and Bismuth for Simultaneous Lead and Cadmium Detection
    Ustabasi, Gul Sirin
    Yilmaz, Ismail
    Ozcan, Mustafa
    Cetinkaya, Ebru
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (10)
  • [27] Silver/Bismuth/Nafion Modified Pencil Graphite Electrode for Trace Heavy Metal Determination
    Palisoc, Shirley
    Espique, Ella Mae
    Ribay, Alein Marimel
    Sy, Steffanie
    Tan, Kyelle Ardelle
    De Jesus, Nico
    Noel, Marissa
    Natividad, Michelle
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (11): : 10355 - 10367
  • [28] Spin Coated Hexaammineruthenium(III)/Nafion/ITO electrodes for the Determination of Lead(II) and Cadmium(II) via Anodic Stripping Voltammetry
    Palisoc, Shirley T.
    Kaw, Kevin Anthony Y.
    Natividad, Michelle T.
    Robles, Julita C.
    JOURNAL OF NEW MATERIALS FOR ELECTROCHEMICAL SYSTEMS, 2017, 20 (02) : 77 - 82
  • [29] A binderless, covalently bulk modified electrochemical sensor: Application to simultaneous determination of lead and cadmium at trace level
    Kempegowda, Raghu Gunigollahalli
    Malingappa, Pandurangappa
    ANALYTICA CHIMICA ACTA, 2012, 728 : 9 - 17
  • [30] Design and Fabrication of Flexible Copper Sensor Decorated with Bismuth Micro/Nanodentrites to Detect Lead and Cadmium in Noninvasive Samples of Sweat
    de Campos, Anderson M.
    Silva, Robson R.
    Calegaro, Marcelo L.
    Raymundo-Pereira, Paulo A.
    CHEMOSENSORS, 2022, 10 (11)