Cyanoacrylate glue mesh fixation versus suture mesh fixation in Lichtenstein inguinal hernia repair

被引:2
|
作者
Arafa, Ahmed Salah [1 ]
Khairy, Mostafa Mohamed [1 ]
Rushdy, Tamer [1 ]
Gomaa, Mohammad Alsayed [1 ]
机构
[1] Zagazig Univ, Zagazig Univ Hosp, Dept Gen Surg, Zagazig 44511, Egypt
来源
EGYPTIAN JOURNAL OF SURGERY | 2019年 / 38卷 / 03期
关键词
hernia repair; Histoacryl; mesh fixation; sutures; CHRONIC PAIN; TRIAL;
D O I
10.4103/ejs.ejs_37_19
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Lichtenstein hernioplasty is becoming more popular in repairing inguinal hernia as it has a low recurrence rate, simplicity to learn, teach, and low costs to the hospital. Cyanoacrylate adhesives have developed over time, mainly through the lengthening of their chemical chains, making them more biocompatible, leading to minimize the toxicity and adverse effects in the host tissue, so it is an optimal choice for the atraumatic mesh fixation. The aim of our study is clarifying the efficacy of the cyanoacrylate glue versus nonabsorbable sutures for mesh fixation in Lichtenstein hernia repair methods with special regard to postoperative groin pain, operative duration, and any other postoperative complications during the follow-up. Patients and methods One hundred and sixty patients with primary inguinal hernia managed by the Lichtenstein hernioplasty were randomized into two groups to receive either glue (Histoacryl) or nonabsorbable polypropylene sutures for polypropylene mesh fixation. The chronic groin pain, recurrence, and other complications were analyzed postoperatively. The statistical analysis was carried out using the Statistical Package for the Social Science. Results We reached 160 patients to the present study. There was a significant difference regarding the groin pain during the first month postoperatively (acute postoperative pain) that is reduced in the glue fixation group (3.8 vs. 25%) (P<0.001). There was no significant differences in the chronic inguinal pain between the study groups that is reduced in the glue fixation group (7.5 vs. 15%) (P=0.133). The operative time was significantly longer in the suture than in the glue (median, 41 min; range, 33-44 min vs. median, 31 min; range, 30-38 min). Conclusion Compared with suture fixation of a mesh, the using of cyanoacrylate glue fixation is a safe and good alternative for Lichtenstein hernia repair with less postoperative pain, a shorter operating time, and a lower rate of recurrences.
引用
收藏
页码:471 / 477
页数:7
相关论文
共 50 条
  • [41] Glue versus suture fixation of mesh in open repair of inguinal hernias: a systematic review and meta-analysis
    Rao, A.
    Colvin, H.
    Amin, A.
    BRITISH JOURNAL OF SURGERY, 2013, 100 : 31 - 31
  • [42] Mesh Fixation at Laparoscopic Inguinal Hernia Repair: A Meta-Analysis Comparing Tissue Glue and Tack Fixation
    Nehal S. Shah
    Catherine Fullwood
    Ajith K. Siriwardena
    Aali J. Sheen
    World Journal of Surgery, 2014, 38 : 2558 - 2570
  • [43] Mesh Fixation at Laparoscopic Inguinal Hernia Repair: A Meta-Analysis Comparing Tissue Glue and Tack Fixation
    Shah, Nehal S.
    Fullwood, Catherine
    Siriwardena, Ajith K.
    Sheen, Aali J.
    WORLD JOURNAL OF SURGERY, 2014, 38 (10) : 2558 - 2570
  • [44] Results of suture fixation of mesh in laparoscopic total extraperitoneal repair of inguinal hernia (TEP)
    Golash, V.
    BRITISH JOURNAL OF SURGERY, 2011, 98 : 152 - 152
  • [45] Fibrin glue versus tacked fixation of mesh in laparoscopic transabdominal preperitoneal repair of inguinal hernia: A prospective study
    Hassanin, Zeinab S.
    Elghamry, Elghamry E.
    Soliman, Soliman M.
    Elsheikh, Mohamed M.
    EGYPTIAN JOURNAL OF SURGERY, 2024, 43 (03): : 806 - 813
  • [46] Randomized Multicenter Trial Comparing Glue Fixation, Self-gripping Mesh, and Suture Fixation of Mesh in Lichtenstein Hernia Repair (FinnMesh Study) (vol 262, pg 714, 2015)
    Roenkae, K.
    Vironen, J.
    Koessi, J.
    ANNALS OF SURGERY, 2016, 263 (01) : 209 - 209
  • [47] Randomized clinical trial of tissue glue versus absorbable sutures for mesh fixation in local anaesthetic Lichtenstein hernia repair
    Paajanen, H.
    Kossi, J.
    Silvasti, S.
    Hulmi, T.
    Hakala, T.
    BRITISH JOURNAL OF SURGERY, 2011, 98 (09) : 1245 - 1251
  • [48] Comparison between fibrin glue versus mechanical mesh fixation in laparoscopic inguinal hernia repair: A prospective study
    Emad, Moustafa M.
    Wakim, Hany R.
    Ali, Mahmoud A.
    Fawzy, Fawzy S.
    EGYPTIAN JOURNAL OF SURGERY, 2025, 44 (01): : 79 - 85
  • [49] Assessment of feasibility and safety of cyanoacrylate glue versus absorbable tacks for inguinal hernia mesh fixation. A prospective comparative study
    Haroon, Muthana
    Morarasu, Stefan
    Morarasu, Bianca Codrina
    Al-Sahaf, Osama
    Eguare, Emmanuel
    VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES, 2023, 18 (01) : 90 - 98
  • [50] Transfascial suture versus tack fixation of mesh in totally extraperitoneal repair of inguinal hernia: A prospective comparative study
    Kumar, Awanish
    Pal, Ajay Kumar
    Choudhary, Anuraag
    Anand, Akshay
    Sonkar, Abhinav Arun
    Pahwa, Harvinder Singh
    JOURNAL OF MINIMAL ACCESS SURGERY, 2020, 16 (02) : 132 - 137