Prepolarized fast spin-echo pulse sequence for low-field MRI

被引:13
|
作者
Kegler, C. [1 ]
Seton, H. C. [1 ]
Hutchison, J. M. S. [1 ]
机构
[1] Univ Aberdeen, Dept Biomed Phys & Bioengn, Aberdeen AB25 2ZD, Scotland
关键词
prepolarized MRI; T-1; contrast; low-field MRI; MRI hardware; field cycling;
D O I
10.1002/mrm.21238
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Clinical MRI systems use magnetic fields of at least 0.5T to take advantage of the increase in signal-to-noise ratio (SNR) with B-0. Low-field MRI apparatus is less expensive and offers the potential benefit of improved T-1 contrast between tissues. The poor inherent SNR at low field can be offset by incorporating prepolarizing field pulses with the MRI pulse sequence. The prepolarizing field does not need to be as homogeneous as the detection field, so it can be generated by a relatively inexpensive electromagnet. Prepolarizing hardware for a 0.01T MRI system was developed together with a prepolarized MRI pulse sequence that incorporates fast imaging techniques to reduce acquisition times by a factor of 5 relative to standard methods. Comparison images of test objects show that most of the enhanced SNR is retained with the fast method. Low-field images of a human wrist acquired using the fast prepolarized method are also shown.
引用
收藏
页码:1180 / 1184
页数:5
相关论文
共 50 条
  • [31] FAST SPIN-ECHO MRI TECHNIQUES - CONTRAST CHARACTERISTICS AND CLINICAL POTENTIAL
    MELKI, P
    MULKERN, RV
    DACHER, JN
    HELENON, O
    HIGUCHI, N
    OSHIO, K
    EINSTEIN, S
    JOLESZ, F
    POURCELOT, L
    JOURNAL DE RADIOLOGIE, 1993, 74 (03): : 179 - 190
  • [32] A SELECTIVE ADIABATIC SPIN-ECHO PULSE
    CONOLLY, S
    NISHIMURA, D
    MACOVSKI, A
    JOURNAL OF MAGNETIC RESONANCE, 1989, 83 (02): : 324 - 334
  • [33] Fast spin echo and fast gradient echo MRI with low acoustic noise
    Hennel, F
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (06) : 960 - 966
  • [34] 3D fast FLAIR: A CSF-nulled 3D fast spin-echo pulse sequence
    Barker, GJB
    MAGNETIC RESONANCE IMAGING, 1998, 16 (07) : 715 - 720
  • [35] MRI SPIN-ECHO RATIO IMAGES
    SINGH, RP
    MITCHELL, MR
    PRICE, RR
    PARTAIN, CL
    JAMES, AE
    INVESTIGATIVE RADIOLOGY, 1985, 20 (06) : S7 - S7
  • [36] Breathhold Multiecho Fast Spin-Echo Pulse Sequence for Accurate R2 Measurement in the Heart and Liver
    Kim, Daniel
    Jensen, Jens H.
    Wu, Ed X.
    Sheth, Sujit S.
    Brittenham, Gary M.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (02) : 300 - 306
  • [37] High resolution 3D imaging of the inner ear with a modified fast spin-echo pulse sequence
    Lee, JN
    King, BD
    Parker, DL
    Buswell, HR
    Harnsberger, HR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01): : 223 - 225
  • [38] BRAIN HEMORRHAGE - EVALUATION WITH FAST SPIN-ECHO AND CONVENTIONAL DUAL SPIN-ECHO IMAGES
    JONES, KM
    MULKERN, RV
    MANTELLO, MT
    MELKI, PS
    AHN, SS
    BARNES, PD
    JOLESZ, FA
    RADIOLOGY, 1992, 182 (01) : 53 - 58
  • [39] Is TrueFISP a gradient-echo or a spin-echo sequence?
    Scheffler, K
    Hennig, J
    MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) : 395 - 397
  • [40] Interactive fast spin-echo imaging
    Busse, RF
    Riederer, SJ
    Fletcher, JG
    Bharucha, AE
    Brandt, KR
    MAGNETIC RESONANCE IN MEDICINE, 2000, 44 (03) : 339 - 348