A Nitrite Biosensor Based on Co-immobilization of Nitrite Reductase and Viologen-modified Chitosan on a Glassy Carbon Electrode

被引:16
|
作者
Quan, De [1 ,2 ,3 ]
Shin, Woonsup [1 ,2 ]
机构
[1] Sogang Univ, Dept Chem, Seoul 121742, South Korea
[2] Sogang Univ, Interdisciplinary Program Integrated Biotechnol, Seoul 121742, South Korea
[3] Qingdao Univ, Dept Chem, Coll Chem Chem Engn & Environm, Qingdao 266071, Shandong, Peoples R China
关键词
biosensor; nitrite reductase; chitosan; viologen; hydrophilic polyurethane; ALCALIGENES-FAECALIS S-6; X-RAY-STRUCTURE; ELECTROCHEMICAL CHARACTERIZATION; METHYL VIOLOGEN; TYPE-2; COPPER; SITE; BINDING; XYLOSOXIDANS; RESIDUES; NITRATE;
D O I
10.3390/s100606241
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical nitrite biosensor based on co-immobilization of copper-containing nitrite reductase (Cu-NiR, from Rhodopseudomonas sphaeroides forma sp. denitrificans) and viologen-modified chitosan (CHIT-V) on a glassy carbon electrode (GCE) is presented. Electron transfer ( ET) between a conventional GCE and immobilized Cu-NiR was mediated by the co-immobilized CHIT-V. Redox-active viologen was covalently linked to a chitosan backbone, and the thus produced CHIT-V was co-immobilized with Cu-NiR on the GCE surface by drop-coating of hydrophilic polyurethane (HPU). The electrode responded to nitrite with a limit of detection (LOD) of 40 nM (S/N = 3). The sensitivity, linear response range, and response time (t(90%)) were 14.9 nA/mu M, 0.04-11 mu M ( r(2) = 0.999) and 15 s, respectively. The corresponding Lineweaver-Burk plot showed that the apparent Michaelis-Menten constant (K-M(app)) was 65 mu M. Storage stability of the biosensor (retaining 80% of initial activity) was 65 days under ambient air and room temperature storage conditions. Reproducibility of the sensor showed a relative standard deviation (RSD) of 2.8% (n = 5) for detection of 1 mu M of nitrite. An interference study showed that anions commonly found in water samples such as chlorate, chloride, sulfate and sulfite did not interfere with the nitrite detection. However, nitrate interfered with a relative sensitivity of 64% and this interference effect was due to the intrinsic character of the NiR employed in this study.
引用
收藏
页码:6241 / 6256
页数:16
相关论文
共 50 条
  • [21] Amperometric Detection of Nitrite on Glassy Carbon Electrode Modified with Cobalt Nitroprusside
    Sabzi, R. E.
    PORTUGALIAE ELECTROCHIMICA ACTA, 2007, 25 (03) : 383 - 390
  • [22] A STUDY OF URICASE BIOSENSOR BASED ON A GLASSY-CARBON ELECTRODE MODIFIED WITH NAFION AND METHYL VIOLOGEN
    JIN, LT
    YE, JS
    TONG, W
    FANG, YZ
    MIKROCHIMICA ACTA, 1993, 112 (1-4) : 71 - 75
  • [23] Bienzymatic glucose biosensor based on co-immobilization of peroxidase and glucose oxidase on a carbon nanotubes electrode
    Zhu, Liande
    Yang, Ruilan
    Zhai, Jiangli
    Tian, Chunyuan
    BIOSENSORS & BIOELECTRONICS, 2007, 23 (04): : 528 - 535
  • [24] Electrochemical detection of aqueous nitrite based on poly(aniline-co-o-aminophenol)-modified glassy carbon electrode
    Liu, Lu
    Cui, Hao
    An, Hao
    Zhai, Jianping
    Pan, Yang
    IONICS, 2017, 23 (06) : 1517 - 1523
  • [25] ELECTROCHEMICAL SENSOR OF NITRITE BASED ON AN INORGANIC FILM-MODIFIED GLASSY-CARBON ELECTRODE
    GAO, ZQ
    ZI, MX
    ZHANG, Y
    WANG, GQ
    ZHAO, ZF
    MIKROCHIMICA ACTA, 1993, 111 (1-3) : 63 - 70
  • [26] Electrochemical detection of aqueous nitrite based on poly(aniline-co-o-aminophenol)-modified glassy carbon electrode
    Lu Liu
    Hao Cui
    Hao An
    Jianping Zhai
    Yang Pan
    Ionics, 2017, 23 : 1517 - 1523
  • [27] Amperometric Determination of Nitrite at Poly(Methylene Blue)-Modified Glassy Carbon Electrode
    Xu, Guang-Ri
    Xu, Guifang
    Xu, Ming-Lu
    Zhang, Zhengqing
    Tian, Yuan
    Cho, Han Nim
    Lee, Won-Yong
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2012, 33 (02): : 415 - 419
  • [28] Electrocatalytic reduction of nitrite on tetraruthenated metalloporphyrins/Nafion glassy carbon modified electrode
    Calfuman, Karla
    Jesus Aguirre, Maria
    Canete-Rosales, Paulina
    Bollo, Soledad
    Llusar, Rosa
    Isaacs, Mauricio
    ELECTROCHIMICA ACTA, 2011, 56 (24) : 8484 - 8491
  • [29] Amperometric biosensor for nitrite and hydrogen peroxide based on hemoglobin immobilized on gold nanoparticles/polythionine/platinum nanoparticles modified glassy carbon electrode
    Zhang, Yu
    Yuan, Ruo
    Chai, Yaqin
    Wang, Jinfen
    Zhong, Huaan
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2012, 87 (04) : 570 - 574
  • [30] Amperometric and impedimetric characterization of a glutamate biosensor based on Nafion® and a methyl viologen modified glassy carbon electrode
    Maalouf, Rita
    Chebib, Hanna
    Saikali, Youssef
    Vittori, Olivier
    Sigaud, Monique
    Jaffrezic-Renault, Nicole
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (11): : 2682 - 2688