Scleral Fixation of Intraocular Lenses with Gore-Tex Suture Refractive Outcomes and Comparison of Lens Power Formulas

被引:34
|
作者
Botsford, Benjamin W. [1 ]
Williams, Andrew M. [1 ]
Conner, Ian P. [1 ]
Martel, Joseph N. [1 ]
Eller, Andrew W. [1 ]
机构
[1] Univ Pittsburgh, Med Ctr, Dept Ophthalmol, Eye & Ear Inst, Pittsburgh, PA USA
来源
OPHTHALMOLOGY RETINA | 2019年 / 3卷 / 06期
关键词
D O I
10.1016/j.oret.2019.02.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report refractive outcomes of scleral-fixated intraocular lens (IOL) implantation with Gore-Tex (W.L. Gore & Associates, Newark, DE) suture and combined pars plana vitrectomy and compare predicted refractive outcomes among 5 IOL power calculation formulas. Design: Retrospective case series. Participants: Patients undergoing scleral-fixated IOL implantation with Gore-Tex suture at our institution between January 2015 and June 2018. Methods: Comparison of preoperative biometrics with postoperative refraction and calculation of predicted refractive outcome with 5 different IOL formulas. Main outcome measures: Prediction error and absolute error to compare postoperative refraction with refraction predicted by lens power calculation formulas. Results: Thirty-one eyes of 31 patients were included. All power calculations assumed in-the-bag position of the IOL. The Akreos A060 (Bausch & Lomb, Rochester, NY) was implanted in 23 eyes and the CZ70BD (Alcon, Fort Worth, TX) in 8 eyes, and all lenses were sutured 3 mm behind the limbus. Average postoperative spherical equivalent (SE) was -0.79 +/- 0.95 diopters (D). Average prediction error (postoperative SE refraction minus target refraction) was -0.19 +/- 0.72 D. Postoperative SE was within 1.0 D of target in 25 of 31 patients (81%) and 2.0 D of target in 31 of 31 patients (100%). The repeated-measures analysis of variance of absolute error by lens power formula was significant (P = 0.012), with Haigis demonstrating greater error. There was no significant difference among Barrett II, Sanders-Retzlaff-Kraff theoretical (SRK/T), Holladay 2, or Hoffer Q. Conclusions: For eyes undergoing pars plana vitrectomy with scleral-sutured IOL implantation, assumption of in-the-bag IOL position when calculating lens power leads to acceptable refractive outcomes. Barrett II, SRK/T, Holladay 2, and Hoffer Q formulas were noninferior to each other. (C)2019 by the American Academy of Ophthalmology
引用
收藏
页码:468 / 472
页数:5
相关论文
共 50 条
  • [21] Scleral Fixation of Posterior Chamber Intraocular Lenses Using Gore-Tex Suture With Concurrent 23-Gauge Pars Plana Vitrectomy
    Khan, Mohammed A.
    Gerstenblith, Adam T.
    Dollin, Michael L.
    Gupta, Omesh P.
    Spirn, Marc J.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2014, 34 (07): : 1477 - 1480
  • [22] Clinical Results After Scleral Fixation of Akreos A060 Lens Using Gore-Tex suture
    Patel, Nimesh
    Yannuzzi, Nicolas Alessandro
    Kuriyan, Ajay E.
    Flynn, Harry W.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [23] Outcomes and Complications of Concurrent Pars Plana Vitrectomy and Scleral-Fixated Intraocular Lens Placement Using Gore-Tex Suture
    Kokame, Gregg T.
    JOURNAL OF VITREORETINAL DISEASES, 2021, 5 (02) : 163 - 164
  • [24] Outcomes and Complications of Concurrent Pars Plana Vitrectomy and Scleral-Fixated Intraocular Lens Placement Using Gore-Tex Suture
    Day, H. Russell
    Durrani, Alia K.
    Kim, Stephen J.
    Patel, Shriji
    JOURNAL OF VITREORETINAL DISEASES, 2020, 4 (02) : 119 - 124
  • [25] ONE-YEAR OUTCOMES OF A NOVEL SURGICAL APPROACH FOR FIXATION OF A POSTERIOR CHAMBER INTRAOCULAR LENS USING GORE-TEX SUTURE
    Bonnell, Alyssa C.
    Mantopoulos, Dimosthenis
    Fine, Howard F.
    Shah, Sumit P.
    Wheatley, H. Matthew
    Prenner, Jonathan L.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (05): : 833 - 837
  • [26] Four-point subconjunctival scleral fixation technique using Gore-Tex suture
    Lee, Kenneth R. C. K.
    Fung, Adrian T.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 49 (04): : 397 - 399
  • [27] A novel surgical approach for fixation of a posterior chamber intraocular lens of Rayner 620 H with Gore-Tex suture
    Wang, Tan
    Chen, Youxin
    Lu, Jun
    Li, Ningning
    Min, Hanyi
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [28] A novel surgical approach for fixation of a posterior chamber intraocular lens of Rayner 620 H with Gore-Tex suture
    Tan Wang
    Youxin Chen
    Jun Lu
    Ningning Li
    Hanyi Min
    BMC Ophthalmology, 23
  • [29] Combined 27-Gauge Pars Plana Vitrectomy and Scleral Fixation of an Akreos AO60 Intraocular Lens Using Gore-Tex Suture
    Khan, Mohammed Ali
    Rahimy, Ehsan
    Gupta, Omesh P.
    Hsu, Jason
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (08): : 1602 - 1604
  • [30] Four-point subconjunctival scleral fixation technique using Gore-Tex suture: Response
    Shah, Yachana
    Shah, Vaibhav
    Raja, Vignesh
    Barrett, Graham D.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 49 (04): : 399 - 400