Removal of High Concentration of Nitrous Oxide for Anesthetic Gas Using Nonthermal Plasma Combined with Adsorbent

被引:0
|
作者
Kuroki, Tomoyuki [1 ]
Yamamoto, Toshiaki [1 ]
Nishii, Shunsuke [1 ]
Akita, Masayuki [2 ]
Okubo, Masaaki [1 ]
机构
[1] Osaka Prefecture Univ, Naka Ku, 1-1 Gakuen Cho, Sakai, Osaka 5998531, Japan
[2] Enomoto BeA Co Ltd, Gifu 5048552, Japan
关键词
High concentration; anesthetic gas; nitrous oxide; decomposition; nonthermal plasma; surface discharge; NOX; DESTRUCTION; REDUCTION; N2O;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nitrous oxide (N2O), which has been used as an anesthetic gas in hospitals, is one of greenhouse gases and it should be removed. Nonthermal plasma is considered to be useful for low concentration gas treatment due to low electron density. N2O is extremely stable in the troposphere and it is difficult to decompose it. In this paper, the high concentration of N2O removal system was investigated using nonthermal plasma combined with adsorbent. N2O gas that simulates the waste gas from anesthetic equipment used for operation rooms was decomposed using the surface discharge plasma reactor. When N2O was decomposed, NO (=NO + NO2) was generated. The generated NO was adsorbed by adsorbent. As a result, 66% of N2O decomposition efficiency was achieved with 12.8% of N2O, the flow rate of 1.1 L/min, and the input power to the plasma reactor of 375 W. Furthermore, 0.4% of NO and 1.0% of NO2 were generated upon N2O decomposition; both of them were removed using adsorbent. The adsorbed NO was able to be decomposed with nitrogen plasma. It was demonstrated that high concentration of N2O removal system can be accomplished using nonthermal plasma combined with adsorbent process. As a practical process, much higher N2O removal without NO formation can be accomplished with a series of plasma reactors with recirculation, followed by N-2 plasma for NO reduction system.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Removal of low-concentration BTX in air using a combined plasma catalysis system
    Fan, X.
    Zhu, T. L.
    Wang, M. Y.
    Li, X. M.
    CHEMOSPHERE, 2009, 75 (10) : 1301 - 1306
  • [42] Improvement of NOx Reduction Efficiency in Diesel Emission Using Nonthermal Plasma - Exhaust Gas Recirculation Combined Aftertreatment
    Okubo, Masaaki
    Kuwahara, Takuya
    Kannaka, Yohei
    Kuroki, Tomoyuki
    Yoshida, Keiichiro
    2010 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2010,
  • [43] A randomized controlled study in reducing procedural pain and anxiety using high concentration nitrous oxide
    Duchicela, Sacha I.
    Meltzer, James A.
    Cunningham, Sandra J.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (11): : 1612 - 1616
  • [44] Nitric Oxide Oxidation and Its Removal in Mist by Nonthermal Plasma: Effects of Discharge Conditions
    Xie, Deyuan
    Sun, Ye
    Zhu, Tianle
    Hou, Liyuan
    Hong, Xiaowei
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2017, 56 (39) : 11336 - 11343
  • [45] A review of the effects of the anesthetic gas nitrous oxide on the immune system; a starting point for future experiences
    Mohsenzadegan, Monireh
    Kourosh Arami, Masoumeh
    Oshaghi, Mojgan
    Sedigh Maroufi, Shahnam
    IMMUNOPHARMACOLOGY AND IMMUNOTOXICOLOGY, 2020, 42 (03) : 179 - 186
  • [46] Enhanced removal of malachite green from wastewater using nonthermal plasma gliding arc discharge combined with ferrate oxidation
    Ouzar, Amina
    Goutomo, Bimo Tri
    Nam, Kijeon
    Kim, Il-Kyu
    DESALINATION AND WATER TREATMENT, 2024, 320
  • [47] Phosphate removal from wastewater using aluminium oxide as adsorbent
    Xie, WM
    Wang, QH
    Ma, HZ
    Ogawa, HI
    INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 2005, 23 (04) : 486 - 491
  • [48] NITROUS-OXIDE MINIMUM ALVEOLAR ANESTHETIC CONCENTRATION IN RATS IS GREATER-THAN PREVIOUSLY REPORTED
    GONSOWSKI, CT
    EGER, EI
    ANESTHESIA AND ANALGESIA, 1994, 79 (04): : 710 - 712
  • [49] A demonstration of the concentration and second gas effects in humans anesthetized with nitrous oxide and desflurane
    Taheri, S
    Eger, EI