Accurate volumetric measurements of anatomical cavities

被引:0
|
作者
Bartz, D
Orman, J
Gürvit, Ö
机构
[1] Univ Tubingen, Visual Comp Med Grp, D-72076 Tubingen, Germany
[2] Univ Hosp Frankfurt, Inst Neuroradiol, Frankfurt, Germany
关键词
radiographic phantom; angiography; measurements; quality assessment;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objectives: The volumetric assessment of anatomical cavities is of high relevance for various applications in medicine. Based on 3D scanning (i.e., CT) of theses cavities, the volume can be determined by counting the volume elements of a segmentation of that cavity. Unfortunately, elements on the boundary of the segmentation require special treatment to obtain accurate volumetric measurements. In this paper, we propose a novel technique that in particular increases the accuracy of the volume estimation for the boundary elements of segmented anatomical objects. Methods: Based on a 3D segmentation of an anatomical cavity, we recursively subdivide boundary volume elements into a set of simple situations, where the volume can be estimated easily. Results: We performed volumetric measurements on seven datasets of phantom models made of plexiglass (see Fig. 1) scanned by a biplane angiography unit and assessed the quality of our method by comparing the measured volume by our novel method and by the fluid required to fill the phantom cavities. Conclusions: Our method calculates a significantly more accurate volume of the segmented cavities than previous methods. Nevertheless, it is only slightly more computationally expensive.
引用
收藏
页码:331 / 335
页数:5
相关论文
共 50 条
  • [21] A RAPID AND ACCURATE VOLUMETRIC METHOD FOR DETERMINATION OF SILICA
    WILSON, HN
    CHEMISTRY & INDUSTRY, 1949, (08) : 124 - 124
  • [22] A method for the accurate volumetric determination of the oxygen in air
    Watson, HE
    JOURNAL OF THE CHEMICAL SOCIETY, 1911, 99 : 1460 - 1466
  • [23] VOLUMETRIC CONTRACTION AND SHRINKAGE CAVITIES BEHAVIOR IN DUCTILE IRON CASTINGS
    TAFAZZOLIYADZI, M
    KONDIC, V
    INTERNATIONAL CAST METALS JOURNAL, 1977, 2 (04): : 41 - 47
  • [24] Hands-On Deformation of Volumetric Anatomical Images on a Touchscreen
    Torres, Rosell
    Rodriguez, Alejandro
    Otaduy, Miguel
    APPLIED SCIENCES-BASEL, 2021, 11 (20):
  • [25] Volumetric analysis and surface reconstruction for anatomical structure modelling
    Malkani, Karan
    Chédot, Claire
    Sequeira, Jean
    Studies in Health Technology and Informatics, 1997, 30 : 191 - 212
  • [26] Microphonics measurements in SRF cavities for RIA
    Kelly, MP
    Shepard, KW
    Kedzie, M
    Fuerst, JD
    Sharamentov, S
    Delayen, J
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 1291 - 1293
  • [27] QUANTUM NONDEMOLITION MEASUREMENTS IN OPTICAL CAVITIES
    ALSING, P
    MILBURN, GJ
    WALLS, DF
    PHYSICAL REVIEW A, 1988, 37 (08): : 2970 - 2978
  • [28] FIELD STRENGTH MEASUREMENTS IN RESONANT CAVITIES
    MAIER, LC
    SLATER, JC
    JOURNAL OF APPLIED PHYSICS, 1952, 23 (01) : 68 - 77
  • [29] Detecting cavities by electrostatic boundary measurements
    Alessandrini, G
    Morassi, A
    Rosset, E
    INVERSE PROBLEMS, 2002, 18 (05) : 1333 - 1353
  • [30] ELECTRIC FIELD MEASUREMENTS IN KLYSTRON CAVITIES
    LISKA, DJ
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1971, ED18 (07) : 450 - &