Long-term evaluation of HVDC transmission line audible noise and its correlation with background noise

被引:7
|
作者
Shin, Koo Yong [1 ]
Oh, Joon Arm [1 ]
Kwon, Gu Min [1 ]
Ju, Mun No [2 ]
Woo, Jeong Min [2 ]
机构
[1] Korea Elect Power Corp KEPCO, KEPRI, Daejeon 34056, South Korea
[2] Korea Electrotechnol Res Inst, Elect Environm Res Ctr, Chang Won 51543, South Korea
来源
AIP ADVANCES | 2019年 / 9卷 / 09期
关键词
ION-FLOW-FIELD; CORONA PERFORMANCE;
D O I
10.1063/1.5111434
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The audible noise (AN) generated by corona discharge from a full-scale, high-voltage direct-current (HVDC) transmission line was evaluated over a one-year period from December 2017 to November 2018. The double bipolar HVDC transmission line using a metallic return conductor was demonstrated using a full-scale tower having a height of 21 m in Gochang, Korea. The measured AN in an outdoor environment was statistically evaluated and compared in different seasons and weather conditions. The A-weighted spectrum of the HVDC corona noise exhibited a greater distribution than the background noise above 1.0 kHz in the frequency domain. Various background noises were considered and eliminated to improve the measurement accuracy. The highest AN levels were exhibited during the spring season. Individuals in the age range of 18-60 years were randomly selected to conduct a human-perception test. The results indicated that 15% of the participants became aware of the AN from the corona discharge when it was >5 dBA greater than the background noise. The AN was <36 dBA when the conductor surface gradient was <18 kV/cm with a six-bundle sub-conductor.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Comparative study on corona-generated audible noise and radio noise of ac long-term operating conductors with two bundle types
    Bian, Xingming
    Chen, Lan
    Zhao, Xuesong
    Chen, Fangdong
    Ji, Jianfei
    Wan, Shuwei
    Wang, Liming
    JOURNAL OF ELECTROSTATICS, 2015, 74 : 47 - 55
  • [32] Altitude Correction Method for Audible Noise of ± 800 kV UHVdc Overhead Transmission Line and its Engineering Application
    Zhao, Luxing
    Xie, Li
    Wang, Dafei
    He, Kun
    Gao, Lei
    Ju, Yong
    Lu, Jiayu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (05) : 3375 - 3386
  • [33] MODIFICATION OF TRANSMISSION-LINE AUDIBLE NOISE SPECTRA TO REDUCE ENVIRONMENTAL-IMPACT
    MOLINO, JA
    ZERDY, GA
    LERNER, ND
    HARWOOD, DL
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (04): : 2120 - 2126
  • [34] METHODS FOR PREDICTING AC TRANSMISSION-LINE AUDIBLE NOISE BY SHORT-TERM SINGLE-PHASE TESTS
    LUNDQUIST, J
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (02): : 283 - 293
  • [35] Investigations on the noise generation phenomena in the PLC system of a long HVDC line
    Moyo, NM
    Ijumba, NM
    Britten, AC
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 953 - 957
  • [36] TELEPHONE NOISE INDUCTION ANALYSIS FOR SQUARE BUTTE HVDC TRANSMISSION-LINE
    PRABHAKARA, FS
    VACERS, I
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (01): : 10 - 10
  • [37] Automatic Detection of Long-Term Audible Noise Indices from Corona Phenomena on UHV AC Power Lines
    Wszolek, T.
    Klaczynski, M.
    ACTA PHYSICA POLONICA A, 2014, 125 (4A) : A93 - A98
  • [38] Transmission Line Effects on the Coil Noise Correlation Matrix in MRI
    Brown, Ryan
    Wang, Yi
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 2032 - 2035
  • [39] A MATHEMATICAL-MODEL OF TRANSMISSION-LINE AUDIBLE NOISE .2. COMPARISON WITH EXPERIMENT
    KIRKHAM, H
    GAJDA, WJ
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (03): : 718 - 728
  • [40] Consistency analysis between the electric field and audible noise caused by UHV test line and UHV transmission line
    Lu, Yao
    Gan, Zhe-Yuan
    Chen, Yu-Chao
    Li, Ni
    Zha, Xian-Guang
    Gaodianya Jishu/High Voltage Engineering, 2011, 37 (02): : 354 - 360