Effect of K-shell absorption edge filters on image quality in digital intraoral radiography

被引:0
|
作者
Shibuya, H [1 ]
Nishikawa, K [1 ]
Kuroyanagi, K [1 ]
机构
[1] Tokyo Dent Coll, Dept Oral & Maxillofacial Radiol, Mihama Ku, Chiba 2618502, Japan
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS | 2000年 / 90卷 / 03期
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The purpose of this study was to investigate the effects of K-shell absorption edge filters on the image quality of a charge-coupled device-based digital intraoral radiographic system. Study design. NIOBI-X, Dental X-ray Beam Filter Kit, and KEY filter were added to a 1-mm thick aluminum filter. The half-value layer and the corresponding effective energy were measured. Digital x-ray images were obtained by using a Computed Dental Radiography (CDR). The sensitivity and the image contrast were compared for each filter. Visual detection tests were conducted to evaluate the depiction ability by using 2 kinds of phantoms. Results. The highest effective energy was produced with the KEY filter, and this high effective energy tended to increase the sensitivity of the CDR. The KEY filter also produced the greatest contrast and had the best depiction ability. Conclusions. The appropriate combination of a charge-coupled device-based digital intraoral radiographic system and an additional filter can reduce the patient dosage and increase the diagnostic information.
引用
收藏
页码:377 / 384
页数:8
相关论文
共 50 条
  • [21] Analysis of image defects in digital intraoral radiography based on photostimulable phosphor plates
    Tashiro, Masayasu
    Nakatani, Atsutoshi
    Sugiura, Kazutaka
    Nakayama, Eiji
    ORAL RADIOLOGY, 2023, 39 (02) : 355 - 363
  • [22] Relationship between image information content and observer performance in digital intraoral radiography
    Takarabe, Shinya
    Okamura, Kazutoshi
    Kuramoto, Taku
    Tokumori, Kenji
    Kato, Toyoyuki
    Yoshiura, Kazunori
    ORAL RADIOLOGY, 2023, 39 (03) : 491 - 503
  • [23] Analysis of image defects in digital intraoral radiography based on photostimulable phosphor plates
    Masayasu Tashiro
    Atsutoshi Nakatani
    Kazutaka Sugiura
    Eiji Nakayama
    Oral Radiology, 2023, 39 : 355 - 363
  • [24] Relationship between image information content and observer performance in digital intraoral radiography
    Shinya Takarabe
    Kazutoshi Okamura
    Taku Kuramoto
    Kenji Tokumori
    Toyoyuki Kato
    Kazunori Yoshiura
    Oral Radiology, 2023, 39 : 491 - 503
  • [25] IMAGE QUALITY CRITERIA APPLIED TO DIGITAL RADIOGRAPHY
    BUSCH, HP
    FAULKNER, K
    MALONE, JF
    RADIATION PROTECTION DOSIMETRY, 1995, 57 (1-4) : 139 - 140
  • [26] DIGITAL RADIOGRAPHY: IMAGE QUALITY AND RADIATION DOSE
    Seibert, J. Anthony
    HEALTH PHYSICS, 2008, 95 (05): : 586 - 598
  • [27] K-shell fluorescence yields and their uncertainties for use in hybrid K-edge densitometry
    Andrew Nicholson
    Stephen Croft
    Robert D. McElroy
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 2069 - 2074
  • [28] K-shell fluorescence yields and their uncertainties for use in hybrid K-edge densitometry
    Nicholson, Andrew
    Croft, Stephen
    McElroy, Robert D., Jr.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (03) : 2069 - 2074
  • [29] PERCEPTION OF IMAGE QUALITY IN DIRECT DIGITAL RADIOGRAPHY AFTER APPLICATION OF VARIOUS IMAGE TREATMENT FILTERS FOR DETECTABILITY OF DENTAL DISEASE
    WENZEL, A
    HINTZE, H
    DENTOMAXILLOFACIAL RADIOLOGY, 1993, 22 (03) : 131 - 134
  • [30] PHOTOELECTRIC K-SHELL AND L-SHELL ABSORPTION COEFFICIENTS FOR HIGHLY IONIZED ATOMS
    MOSZKOWSKI, SA
    MEYEROTT, RE
    ASTROPHYSICAL JOURNAL, 1956, 124 (03): : 537 - 541