Effect of K-shell absorption edge filters on image quality in digital intraoral radiography

被引:0
|
作者
Shibuya, H [1 ]
Nishikawa, K [1 ]
Kuroyanagi, K [1 ]
机构
[1] Tokyo Dent Coll, Dept Oral & Maxillofacial Radiol, Mihama Ku, Chiba 2618502, Japan
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The purpose of this study was to investigate the effects of K-shell absorption edge filters on the image quality of a charge-coupled device-based digital intraoral radiographic system. Study design. NIOBI-X, Dental X-ray Beam Filter Kit, and KEY filter were added to a 1-mm thick aluminum filter. The half-value layer and the corresponding effective energy were measured. Digital x-ray images were obtained by using a Computed Dental Radiography (CDR). The sensitivity and the image contrast were compared for each filter. Visual detection tests were conducted to evaluate the depiction ability by using 2 kinds of phantoms. Results. The highest effective energy was produced with the KEY filter, and this high effective energy tended to increase the sensitivity of the CDR. The KEY filter also produced the greatest contrast and had the best depiction ability. Conclusions. The appropriate combination of a charge-coupled device-based digital intraoral radiographic system and an additional filter can reduce the patient dosage and increase the diagnostic information.
引用
收藏
页码:377 / 384
页数:8
相关论文
共 50 条
  • [1] Image quality with K-edge filter in digital intraoral radiography
    Shibuya, H
    Nishikawa, K
    Kuroyanagi, K
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 958 - 958
  • [2] Image quality assessment of digital intraoral radiography - perception to caries diagnosis
    Yoshiura, Kazunori
    JAPANESE DENTAL SCIENCE REVIEW, 2012, 48 (01) : 42 - 47
  • [3] Image quality assessment and radiation doses in intraoral radiography
    Yakoumakis, EN
    Tierris, CE
    Stefanou, EP
    Phanourakis, IG
    Proukakis, CC
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2001, 91 (03): : 362 - 368
  • [4] ABSOLUTE MEASURES OF IMAGE QUALITY FOR THE SENS-A-RAY DIRECT DIGITAL INTRAORAL RADIOGRAPHY SYSTEM
    WELANDER, U
    MCDAVID, WD
    MORNER, AC
    TRONJE, G
    TOKUOKA, O
    FUCHIHATA, H
    NELVIG, P
    DOVE, SB
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1995, 80 (03): : 345 - 350
  • [5] K-SHELL PHOTOABSORPTION EDGE OF A DENSE ALUMINUM PLASMA
    GODWAL, BK
    NG, A
    DASILVA, L
    LEE, YT
    LIBERMAN, DA
    PHYSICAL REVIEW A, 1989, 40 (08) : 4521 - 4526
  • [6] DIGITAL K-EDGE SUBTRACTION RADIOGRAPHY
    KRUGER, RA
    MISTRETTA, CA
    CRUMMY, AB
    SACKETT, JF
    GOODSITT, MM
    RIEDERER, SJ
    HOUK, TL
    SHAW, CG
    FLEMING, D
    RADIOLOGY, 1977, 125 (01) : 243 - 245
  • [7] RARE-EARTH FILTERS FOR INTRAORAL RADIOGRAPHY - EXPOSURE REDUCTION AS A FUNCTION OF KV(P) WITH COMPARISONS OF IMAGE QUALITY
    KIRCOS, LT
    STANINEC, M
    CHOU, L
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1989, 118 (05): : 605 - 609
  • [8] X-ray absorption near edge structures of DNA or its components around the oxygen K-shell edge
    Akamatsu, K
    Yokoya, A
    RADIATION RESEARCH, 2001, 155 (03) : 449 - 452
  • [9] Image Acquisition and Quality in Digital Radiography
    Alexander, Shannon
    RADIOLOGIC TECHNOLOGY, 2016, 88 (01) : 53 - 66
  • [10] Image Quality in Digital Industrial Radiography
    Ewert, Uwe
    Zscherpel, Uwe
    Heyne, Klara
    Jechow, Mirko
    Bavendiek, Klaus
    MATERIALS EVALUATION, 2012, 70 (08) : 955 - 964