Performance Analysis of Variable Mode Adsorption Chiller at Different Recooling Water Temperatures

被引:4
|
作者
Alsarayreh, Ahmad A. [1 ]
Al-Maaitah, Ayman [2 ]
Attarakih, Menwer [3 ]
Bart, Hans-Joerg [4 ]
机构
[1] Precision Ind, POB 37448, Dubai, U Arab Emirates
[2] Wahaj Investment LLC, 24B St,Comm 365,Ind 2,POB 37448, Dubai, U Arab Emirates
[3] Univ Jordan, Dept Chem Engn, Queen Rania St, Amman 11942, Jordan
[4] TU Kaiserslautern, Therm Verfahrenstech, D-67653 Kaiserslautern, Germany
关键词
adsorption; zeolite; SAPO-34; adsorption cooling; mass recovery; variable mode; MASS RECOVERY; HEAT-PUMP;
D O I
10.3390/en14133871
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Adsorption cooling can recover waste heat at low temperature levels, thereby saving energy and reducing greenhouse gas emissions. An air-cooled adsorption cooling system reduces water consumption and the technical problems associated with wet-cooling systems; however, it is difficult to maintain a constant recooling water temperature using such a system. To overcome this limitation, a variable mode adsorption chiller concept was introduced and investigated in this study. A prototype adsorption chiller was designed and tested experimentally and numerically using the lumped model. Experimental and numerical results showed good agreement and a similar trend. The adsorbent pairs investigated in this chiller consisted of silicoaluminophosphate (SAPO-34)/water. The experimental isotherm data were fitted to the Dubinin-Astakhov (D-A), Freundlich, Hill, and Sun and Chakraborty (S-C) models. The fitted data exhibited satisfactory agreement with the experimental data except with the Freundlich model. In addition, the adsorption kinetics parameters were calculated using a linear driving force model that was fitted to the experimental data with high correlation coefficients. The results show that the kinetics of the adsorption parameters were dependent on the partial pressure ratio. Four cooling cycle modes were investigated: single stage mode and mass recovery modes with duration times of 25%, 50%, and 75% of the cooling cycle time (denoted as short, medium, and long mass recovery, respectively). The cycle time was optimized based on the maximum cooling capacity. The single stage, short mass recovery, and medium mass recovery modes were found to be the optimum modes at lower (<35 degrees C), medium (35-44 degrees C), and high (>44 degrees C) recooling temperatures. Notably, the recooling water temperature profile is very important for assessing and optimizing the suitable working mode.
引用
收藏
页数:26
相关论文
共 50 条
  • [21] Energy Efficiency Analysis of a Chiller Using Variable Chilled Water and Cooling Water Flow Control
    Wen, Xiantai
    Liang, Caihua
    Zhang, Xiaosong
    Xu, Guoxing
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 222 - 229
  • [22] Performance and Greenhouse Gas Analysis of a Solar Adsorption Chiller for Canadian Residential Applications
    McNally, Jordan
    Cruickshank, Cynthia A.
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2019 AND THE IEA SHC SOLAR HEATING AND COOLING CONFERENCE FOR BUILDINGS AND INDUSTRY 2019, 2019, : 2552 - 2563
  • [23] Analysis of operation and construction parameters for adsorption chiller performance with MATLAB/Simulink simulation
    Ilis, Gamze Gediz
    Demir, Hasan
    Saha, Bidyut Baran
    APPLIED THERMAL ENGINEERING, 2021, 198
  • [24] Performance analysis of control valves for a novel adsorption chiller with thermal energy storage
    Clausel, Tagne Takote Brice
    Anyanwu, Cosmas
    Eke, Mkpamdi
    Mokom, Charity
    CASE STUDIES IN THERMAL ENGINEERING, 2025, 69
  • [25] Dynamic Performance Analysis for an Absorption Chiller under Different Working Conditions
    Wang, Jian
    Shang, Sheng
    Li, Xianting
    Wang, Baolong
    Wu, Wei
    Shi, Wenxing
    APPLIED SCIENCES-BASEL, 2017, 7 (08):
  • [26] Compact Ammonia/Water Absorption Chiller of Different Cycle Configurations: Parametric Analysis Based on Heat Transfer Performance
    Tao, Xuan
    Thanganadar, Dhinesh
    Patchigolla, Kumar
    ENERGIES, 2022, 15 (18)
  • [27] Performance modelling of a two-bed silica gel-water pair adsorption chiller
    Clausel, Tagne Takote Brice
    Anyanwu, Cosmas N.
    Eke, Mkpamdi
    Abam, Fidelis
    Ojike, Onyekwere
    RESULTS IN ENGINEERING, 2025, 25
  • [28] Performance Investigation of a Solar Heat Driven Adsorption Chiller under Two Different Climatic Conditions
    Choudhury B.
    Chatterjee P.K.
    Habib K.
    Saha B.B.
    Journal of The Institution of Engineers (India): Series C, 2018, 99 (3) : 347 - 354
  • [29] Structural Design and Performance Analysis of a Small Thermoelectric Chiller With Variable Temperature Heat Reservoirs
    Jiang, Fan
    Meng, Fan-Kai
    Chen, Lin-Gen
    Sheng, Jia-Feng
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2020, 41 (07): : 1573 - 1578
  • [30] Performance analysis of a waste heat driven activated carbon based composite adsorbent - Water adsorption chiller using simulation model
    Tso, C. Y.
    Chao, Christopher Y. H.
    Fu, S. C.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (25-26) : 7596 - 7610