Safety of contrast dobutamine stress echocardiography: A single center experience

被引:37
|
作者
Timperley, J [1 ]
Mitchell, ARJ
Thibault, H
Mirza, IH
Becher, H
机构
[1] John Radcliffe Hosp, Dept Cardiol, Oxford, England
[2] Hop Louis Pradel, Lyon, France
关键词
D O I
10.1016/j.echo.2004.09.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Contrast is, increasingly being used during dobutamine stress echocardiography. However, there are few data regarding the safety of this combination. Methods: We retrospectively analyzed 751 consecutive stress echocardiograms, 332 without contrast and 419 with contrast (299 with Sonouve, 120 with Optison). Reported side effects and physiologic data were then compared. Results: There were no fatalities. The incidence of side effects was similar in the 3 groups. The Optison group had a lower diastolic blood pressure compared with the noncontrast group (P < .05) at rest, and the Sonovue group had a higher peak heart rate compared with the noncontrast group (P < .001). Patients receiving Optison had more premature atrial contractions (P < .05) but there was no difference in the incidence of ventricular tachycardia, supraventricular tachycardia, or vagally mediated episodes. Conclusion. The use of contrast during dobutamine stress echocardiography was not associated with an increased risk of side effects.
引用
收藏
页码:163 / 167
页数:5
相关论文
共 50 条
  • [41] Safety and diagnostic value of dobutamine stress echocardiography in patients with hypertension
    Nemchyna, OO
    Lutay, MI
    Tsyzh, OV
    Golikova, IP
    JOURNAL OF HYPERTENSION, 2005, 23 : S165 - S166
  • [42] Diagnostic performance of dobutamine stress echocardiography: A South African experience
    Scherman, L.
    Cilliers, C.
    Odendaal, D.
    Saaiman, J. A.
    Heradien, M. J.
    Dippenaar, A. P.
    Swart, Y.
    Louw, J.
    Brink, P. A.
    van der Bijl, P.
    SAMJ SOUTH AFRICAN MEDICAL JOURNAL, 2022, 112 (06): : 433 - 436
  • [43] Dobutamine stress echocardiography: Initial experience with pediatric transplant recipients
    Pahl, E
    Swenson, J
    Crawford, S
    Chrystof, D
    Backer, CL
    Fricker, FJ
    Mavroudis, C
    Chaudhry, FA
    PEDIATRICS, 1996, 98 (03) : 28 - 28
  • [44] Cardiac rupture during contrast-enhanced dobutamine stress echocardiography
    Datino, T
    García-Fernández, MA
    Martínez-Sellés, M
    Quiles, J
    Avanzas, P
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 98 (02) : 349 - 350
  • [45] Safety of myocardial flash-contrast echocardiography in combination with dobutamine stress testing for the detection of ischaemia in 5250 studies
    Aggeli, C.
    Giannopoulos, G.
    Roussakis, G.
    Christoforatou, E.
    Marinos, G.
    Toli, C.
    Pitsavos, C.
    Stefanadis, C.
    HEART, 2008, 94 (12) : 1571 - 1577
  • [46] Safety and feasibility of real time myocardial perfusion imaging with intravenous ultrasound contrast during dobutamine stress echocardiography
    Tsutsui, JM
    Xie, F
    Elhendy, A
    McGrain, AC
    Cory, B
    Garvin, R
    Porter, TR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 303A - 304A
  • [47] Dobutamine stress echocardiography: Experience in pediatric heart transplant recipients
    Pahl, E
    Crawford, SE
    Swenson, JM
    Duffy, CE
    Fricker, FJ
    Backer, CL
    Mavroudis, C
    Chaudhry, FA
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 1999, 18 (07): : 725 - 732
  • [48] Safety of Ultrasound Contrast Agents in Stress Echocardiography
    Gabriel, Ruvin S.
    Smyth, Yvonne M.
    Menon, Venu
    Klein, Allan L.
    Grimm, Richard A.
    Thomas, James D.
    Sabik, Ellen Mayer
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (09): : 1269 - 1272
  • [49] Safety and efficacy of physiologist-led dobutamine stress echocardiography: Experience from a tertiary cardiac centre
    Ntoskas T.
    Ahmad F.
    Woodmansey P.
    Echo Research & Practice, 2018, 5 (3): : 105 - 112
  • [50] Safety and efficacy of dobutamine atropine stress: Prediction of submaximal stress in 3020 patients studied at a single center
    Secknus, MA
    Marwick, TH
    CIRCULATION, 1996, 94 (08) : 2235 - 2235