Direct current electrical stimulation increases the fusion rate of spinal fusion cages

被引:34
|
作者
Toth, JM
Seim, HB
Schwardt, JD
Humphrey, WB
Wallskog, JA
Turner, AS
机构
[1] Med Coll Wisconsin, Dept Orthopaed Surg, Milwaukee, WI 53226 USA
[2] Colorado State Univ, Dept Clin Sci, Ft Collins, CO 80523 USA
[3] Electrobiol Inc, Parsippany, NJ USA
关键词
bone healing; direct current stimulation; electric stimulation; lumbar vertebrae; spinal fusion; spine fusion cages;
D O I
10.1097/00007632-200010150-00007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A randomized experimental evaluation of direct current stimulation in a validated animal model with an experimental control group, using blinded radiographic, biomechanical, histologic, and statistical measures. Objectives. To evaluate the efficacy of the adjunctive use of direct current stimulation on the fusion rate and speed of healing of titanium interbody fusion cages packed with autograft in a sheep lumbar interbody fusion model. Summary of Background Data. Titanium lumbar interbody spinal fusion cages have been reported to be 90% effective for Single-level lumbar interbody fusion. However, fusion rates are reported to be between 70% and 80% in patients with multilevel fusions or with risk factors such as obesity, tobacco use, or metabolic disorders. The authors hypothesized that direct current stimulation would increase the fusion rate of titanium interbody fusion cages packed with autograft in a sheep lumbar interbody fusion model. Methods. Twenty-two sheep underwent lumbar:discectomy and fusion at L4-L5 with an 11- x 20-mm Bagby and Kuslich (BAK) cage packed with autograft. Seven sheep received a BAK cage and no current. Seven sheep; had a cage and a 40-muA current applied with a direct current stimulator. Eight sheep bad a BAK cage and a 100-muA current applied. All sheep were killed 4 months after surgery. The efficacy of electrical stimulation in, promoting interbody fusion was assessed by performing radiographic, biomechanical, and histologic analyses in a blinded fashion. Results. The histologic fusion rate increased as the direct current dose increased from 0 muA to 40 muA to 100 muA (P < 0.009). Histologically, all animals in the 100-<mu>A group had fusions in both the right and left sides of the cage. Direct current stimulation had a significant effect on increasing the stiffness of the treated motion segment in right lateral bending (P < 0.120), left lateral bending (P < 0.017), right axial rotation (P < 0.004), left axial rotation (P< 0.073), extension (P < 0.078), and flexion (P < 0.029) over nonstimulated levels. Conclusion. Direct current stimulation increased the histologic and biomechanical fusion rate and the speed of healing of lumbar interbody spinal fusion cages in an ovine model at 4 months.
引用
收藏
页码:2580 / 2587
页数:8
相关论文
共 50 条
  • [41] Early revision rate after posterior spinal fusion surgery increases with every additional BMI point
    Hammer, Alexander
    Goetz, Achim
    Rappert, Denis
    Cheremina, Olga
    Eibl, Thomas
    Tischer, Thomas
    Lembcke, Bjoern
    Schnake, Klaus John
    EUROPEAN SPINE JOURNAL, 2025,
  • [42] Efficacy of Electrical Stimulation for Spinal Fusion: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
    Akhter, Shakib
    Qureshi, Abdul Rehman
    Aleem, Idris
    El-Khechen, Hussein Ali
    Khan, Shadman
    Sikder, Omaike
    Khan, Moin
    Bhandari, Mohit
    Aleem, Ilyas
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [43] Direct current electrical stimulation in the treatment of aphasia
    Montenegro, Ismael R.
    Alvarez-Montesinos, Juan A.
    Estudillo, Alejandro J.
    Garcia-Orza, Javier
    REVISTA DE NEUROLOGIA, 2017, 65 (12) : 553 - 562
  • [44] Current use of biologic graft extenders for spinal fusion
    Coseo, N. M.
    Saldua, N.
    Harrop, J.
    JOURNAL OF NEUROSURGICAL SCIENCES, 2012, 56 (03) : 203 - 207
  • [45] Failure in Lumbar Spinal Fusion and Current Management Modalities
    Cruz, Alex
    Ropper, Alexander E.
    Xu, David S.
    Bohl, Michael
    Reece, Edward M.
    Winocour, Sebastian J.
    Buchanan, Edward
    Kaung, Geoffrey
    SEMINARS IN PLASTIC SURGERY, 2021, 35 (01) : 54 - 62
  • [46] Failure in Cervical Spinal Fusion and Current Management Modalities
    Verla, Terence
    Xu, David S.
    Davis, Matthew J.
    Reece, Edward M.
    Kelly, Michelle
    Nunez, Mervin
    Winocour, Sebastian J.
    Ropper, Alexander E.
    SEMINARS IN PLASTIC SURGERY, 2021, 35 (01) : 10 - 13
  • [47] Radiological evaluation of anterior lumbar fusion using PEEK cages with adjacent vertebral autograft in spinal deformity long fusion surgeries
    Jianqiang Ni
    Yanping Zheng
    Ning Liu
    Xin Wang
    Xiutong Fang
    Rishabh Phukan
    Kirkham B. Wood
    European Spine Journal, 2015, 24 : 791 - 799
  • [48] Radiological evaluation of anterior lumbar fusion using PEEK cages with adjacent vertebral autograft in spinal deformity long fusion surgeries
    Ni, Jianqiang
    Zheng, Yanping
    Liu, Ning
    Wang, Xin
    Fang, Xiutong
    Phukan, Rishabh
    Wood, Kirkham B.
    EUROPEAN SPINE JOURNAL, 2015, 24 (04) : 791 - 799
  • [49] PEEK versus titanium-coated PEEK cervical cages: fusion rate
    Godlewski, Bartosz
    Bebenek, Adam
    Dominiak, Maciej
    Karpinski, Grzegorz
    Cieslik, Piotr
    Pawelczyk, Tomasz
    ACTA NEUROCHIRURGICA, 2022, 164 (06) : 1501 - 1507
  • [50] PEEK versus titanium-coated PEEK cervical cages: fusion rate
    Bartosz Godlewski
    Adam Bebenek
    Maciej Dominiak
    Grzegorz Karpinski
    Piotr Cieslik
    Tomasz Pawelczyk
    Acta Neurochirurgica, 2022, 164 : 1501 - 1507