Relay protection system of transmission line based on AI

被引:5
|
作者
Zheng, Xiangyu [1 ,2 ]
Jia, Rong [1 ,3 ]
Gong, Linling [4 ]
Aisikaer [5 ]
Ma, Xiping [2 ]
Dang, Jian [1 ]
Lv, Zhihan
机构
[1] Xian Univ Technol, Sch Elect Engn, Xian, Shaanxi, Peoples R China
[2] State Grid GanSu Elect Power Res Inst, Lanzhou, Gansu, Peoples R China
[3] Xian Univ Technol, Energy Intelligence Lab, Xian, Shaanxi, Peoples R China
[4] Lanzhou Petrochem Coll Vocat Technol, Lanzhou, Gansu, Peoples R China
[5] Xinjiang Goldwind Sci & Technol Co Ltd, Urumqi, Xinjiang, Peoples R China
来源
PLOS ONE | 2021年 / 16卷 / 04期
关键词
ARTIFICIAL NEURAL-NETWORK;
D O I
10.1371/journal.pone.0246403
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
With the development of modern power systems, higher requirements are imposed on relay protection technology. Traditional relay protection and fault diagnosis technologies have been unable to meet the requirements of the continuous development of power systems, and relay protection systems based on artificial intelligence(AI) technology have received increasing attention. Therefore, this document first analyses the weaknesses of traditional broadcast line protection and uses the adaptability and self-learning of artificial intelligence(AI); to propose the concept of protection of a relay line based on AI. In combination with the artificial nervous network, the AI-based relay protection system shall be studied and the experimental model shall be developed. This paper validates it with simulation experiments. The research results show that for the analysis of the ANN test results of the subnetwork, the actual output of the subnetwork is very close to the ideal output, and the error does not exceed 0.2%. The system has good performance and high reliability.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Optimized design of relay protection for an offshore wind power outgoing transmission line
    Xue M.
    Chen F.
    Yang L.
    Qiu Y.
    Yang L.
    Yu C.
    Xing W.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (20): : 150 - 159
  • [32] Six-Phase Transmission Line over Current Protection by Numerical Relay
    Warathe, Shanker
    Patel, R. N.
    ICACCS 2015 PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING & COMMUNICATION SYSTEMS, 2015,
  • [33] Modelling and simulation of the impact of SVC on existing distance relay for transmission line protection
    Behera, Sabyasachi
    Raja, P.
    Moorthi, S.
    2015 INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON), 2015, : 151 - 156
  • [34] Analysis of Polygonal Distance Protection Relay of Transmission Line Affected by SMES Device
    Yang, Jun
    Zhang, Wenjia
    PROCEEDINGS OF THE 26TH INTERNATIONAL SYMPOSIUM ON SUPERCONDUCTIVITY (ISS 2013), 2014, 58 : 272 - 276
  • [35] Quadrilateral Relay Based Distance Protection Scheme for Transmission Lines under Varying System Conditions
    Aneesh, S.
    Angel, T. S.
    PROCEEDINGS OF IEEE INTERNATIONAL CONFERENCE ON TECHNOLOGICAL ADVANCEMENTS IN POWER AND ENERGY, 2015, : 35 - 39
  • [36] A plug and play model for JINI based on-line relay control for power system protection
    Nithiyananthan, Kannan
    Ramachandran, Velimuthu
    International Journal for Engineering Modelling, 2008, 21 (1-4) : 65 - 68
  • [37] Transmission line protection system based on TMS320F2812
    Zhou, Yun
    Yang, Jiang-Li
    Lu, Qing-Qi
    Gaoya Dianqi/High Voltage Apparatus, 2005, 41 (04): : 289 - 291
  • [38] Management system of transmission line passage protection based on web map service
    Jiang, Hui Lan
    Zheng, Shuang Qi
    Li, Ning
    Applied Mechanics and Materials, 2014, 492 : 182 - 185
  • [39] Management System of Transmission Line Passage Protection Based on Web Map Service
    Jiang, Huilan
    Zheng, Shuangqi
    Li, Ning
    POWER AND ENERGY SYSTEMS III, 2014, 492 : 182 - +
  • [40] A study on distance relay overload zone setting for transmission line protection using dynamic line rating
    Kim Y.-G.
    Kim M.-S.
    Kang S.-H.
    Transactions of the Korean Institute of Electrical Engineers, 2020, 69 (03): : 402 - 408