Rebinning Methods for Cone Beam SPECT Reconstruction with Non-uniform Attenuation

被引:0
|
作者
Chen, Yunbin [1 ]
Wen, Junhai [1 ]
Wang, Li [1 ]
Hu, Peng [1 ]
Zhang, Hao [1 ]
机构
[1] Beijing Inst Technol, Sch Life Sci & Technol, Dept Biomed Engn, Beijing 100081, Peoples R China
关键词
SPECT; single slice rebinning; cone beam; non-uniform attenuation;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Single photon emission computed tomography (SPELT) could achieve the functional image of the organ of interest, so the diseases can be found much earlier. Cone-beam SPELT reconstruction can improve the photo density and spatial resolution of the reconstructed image. A simple method for cone beam reconstruction is to rebin the cone-beam projection data into 2D sinograms and use 2D reconstruction method to obtain the 3D reconstructed images. In this paper, we proposed two rebinning methods for cone-beam SPELT reconstruction with non-uniform attenuation, these two algorithms both can obtain good reconstruction results, especially when reconstructed slice is close to the mid-plane.
引用
收藏
页码:337 / 340
页数:4
相关论文
共 50 条
  • [21] IMPROVEMENT OF QUANTITATION IN SPECT - ATTENUATION AND SCATTER CORRECTION USING NON-UNIFORM ATTENUATION DATA
    MUKAI, T
    TORIZUKA, K
    DOUGLASS, KH
    WAGNER, HN
    JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (05) : P91 - P91
  • [22] An analytical approach for compensation of non-uniform attenuation in cardiac SPECT imaging
    Glick, SJ
    King, MA
    Pan, TS
    Soares, EJ
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1713 - 1717
  • [23] Is non-uniform attenuation correction necessary for clinical brain perfusion SPECT?
    Van Laere, KJ
    Audenaert, K
    Versijpt, J
    Koole, M
    Kalmar, A
    Dumont, F
    Dierckx, RA
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 186P - 186P
  • [24] Analytical approach for compensation of non-uniform attenuation in cardiac SPECT imaging
    Glick, S.J.
    King, M.A.
    Pan, Tin-Su
    Soares, E.J.
    Physics in Medicine and Biology, 1995, 40 (10):
  • [25] A ray-driven approach to analytical SPECT reconstruction of non-uniform attenuation with variable focal-length fan-beam collimators
    Wen, JH
    Li, TF
    Liang, ZR
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 731 - 735
  • [26] Region-dependent Gaussian regularization of least square SPECT reconstruction with non-uniform attenuation correction.
    Riddell, C
    N'Guyen, T
    Benali, H
    Todd-Pokropek, A
    Buvat, I
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 58P - 58P
  • [27] WEIGHTED BACKPROJECTION IMPLEMENTED WITH A NON-UNIFORM ATTENUATION MAP FOR IMPROVED SPECT QUANTITATION
    MANGLOS, SH
    JASZCZAK, RJ
    FLOYD, CE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 625 - 628
  • [28] Comparison of two different methods for non-uniform attenuation correction of TC-99m myocardial SPECT
    Boening, G
    Ziegler, S
    Ficaro, EP
    DeBruin, S
    Briandet, P
    Hawman, E
    Sutter, SM
    Schwaiger, M
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 904 - 904
  • [29] Analytical fan-beam and cone-beam reconstruction algorithms with uniform attenuation correction
    Tang, QL
    Zeng, GL
    Gullberg, GT
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3546 - 3550
  • [30] Improvement of SPET using iterative reconstruction and non-uniform attenuation correction
    Kauppinen, V
    Alenius, S
    Koskinen, MO
    Kuikka, JT
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (01): : S89 - S89