The utility of bispectral index monitoring in flexible bronchoscopy: A single-center, retrospective observational study

被引:5
|
作者
Yamada, Jun [1 ]
Hazama, Daisuke [1 ]
Tachihara, Motoko [1 ]
Kawanami, Yuki [2 ]
Kawaguchi, Aki [1 ]
Yatani, Atsuhiko [1 ]
Sato, Hiroki [1 ]
Mimura, Chihiro [1 ]
Katsurada, Naoko [1 ]
Yamamoto, Masatsugu [1 ]
Nishimura, Yoshihiro [1 ]
Kobayashi, Kazuyuki [1 ]
机构
[1] Kobe Univ, Dept Internal Med, Div Resp Med, Grad Sch Med, Kobe, Hyogo, Japan
[2] Kobe Univ Hosp, Dept Clin Engn, Kobe, Hyogo, Japan
关键词
BIS value; flexible bronchoscopy; MOAA; S score; sedation; SEDATION SCALE; PROPOFOL;
D O I
10.1111/1759-7714.14658
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background The desired depth of sedation during flexible bronchoscopy is one in which verbal contact is possible whenever necessary. Although it is common that the depth of sedation is assessed by validated instruments such as the modified observer's assessment of alertness and sedation (MOAA/S) score, the repeated stimulation associated with the assessment can affect the sedation. The bispectral index (BIS) has been widely used for general anesthesia due to its objective and noninvasive nature. However, the utility of BIS monitoring and a target BIS value for use during bronchoscopy have not been fully elucidated. Methods We performed a retrospective observational study to assess the utility of the BIS value for monitoring conscious sedation during bronchoscopy at Kobe University Hospital from August 2020 to April 2021. Results Eighteen patients underwent bronchoscopy with BIS monitoring. The BIS value significantly correlated with the MOAA/S score (r = 0.2, p < 0.01), and the correlation was stronger in sufficiently sedated patients (r = 0.486, p < 0.01). The lowest MOAA/S score during the procedure was highly correlated with the BIS value (r = 0.625, p < 0.01). The BIS monitoring seemed to be more sensitive to changes in the sedation level than the MOAA/S score, heart rate and mean arterial pressure. The median BIS value at an MOAA/S score of 3-4, the desired depth of sedation, was 82.0. Conclusions BIS value is useful for monitoring sedation during bronchoscopy. This study suggests that a BIS value of 82 reflects an adequate level of sedation.
引用
收藏
页码:3052 / 3057
页数:6
相关论文
共 50 条
  • [21] Bispectral index monitoring: Optimizing anesthesia in rigid bronchoscopy
    Adiyeke, Ozal
    Sarban, Onur
    Mendes, Ergun
    Akca, Hilal
    Turan, Engin Ihsan
    Demirkol, Baris
    Ozgul, Mehmet Akif
    Gumus Ozcan, Funda
    TUBERKULOZ VE TORAKS-TUBERCULOSIS AND THORAX, 2024, 72 (03):
  • [22] Clinical utility of bispectral index monitoring in the ICU: A pilot study
    Khan, Akram
    Dernaika, Tarek
    Haugland, Katherine
    Trottier, Steven
    Kinasewitz, Gary
    CHEST, 2006, 130 (04) : 225S - 226S
  • [23] Treatment of Flexible Bronchoscopy for Bronchial Foreign Bodies, A Single-Center Investigation
    Miyashita, Y.
    Takagi, H.
    Okamoto, S.
    Koyama, R.
    Shimada, N.
    Nagaoka, T.
    Takahashi, K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [24] Bispectral index values during elective rigid bronchoscopy: a prospective observational pilot study
    Bould, M. D.
    Mahtani, D. G.
    Davies, R.
    Roughton, M.
    Hunter, D. N.
    Kelleher, A.
    ANAESTHESIA, 2007, 62 (05) : 438 - 445
  • [25] Influence of HeartMate 3™ on Bispectral Index™ monitor: a retrospective observational study
    Azuma, Seiichi
    Asamoto, Masaaki
    Akabane, Shinichi
    Ezaka, Mariko
    Otsuji, Mikiya
    Uchida, Kanji
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2025,
  • [26] Effectiveness of Zinc Supplementation for Sepsis Treatment: A Single-Center Retrospective Observational Study
    Kim, Muneyoshi
    Maruhashi, Takaaki
    Asari, Yasushi
    NUTRIENTS, 2024, 16 (17)
  • [27] Thromboelastometry profile in critically ill patients: A single-center, retrospective, observational study
    Crochemore, Tomaz
    Correa, Thiago Domingos
    Lance, Marcus D.
    Solomon, Cristina
    Neto, Ary Serpa
    de Campos Guerra, Joao Carlos
    Lellis, Priscila Scolmeister
    Bernz, Livia Muller
    Nunes, Natalia
    Mancio, Cassio Massashi
    Hitomi Yokoyama, Ana Paula
    Silva, Eliezer
    PLOS ONE, 2018, 13 (02):
  • [28] Efficacy and safety of leadless ventricular pacemaker: a single-center retrospective observational study
    Yan, Lin
    Ling, Lin
    Song, Yumeng
    Jiang, Tingbo
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2024, 14 (05) : 878 - 889
  • [29] Risk factors for mortality in aspiration pneumonia: a single-center retrospective observational study
    Ito, Madoka
    Ishimaru, Naoto
    Shimokawa, Toshio
    Kizawa, Yoshiyuki
    MONALDI ARCHIVES FOR CHEST DISEASE, 2023, 93 (03)
  • [30] Frequency and Management of Hemorrhagic Malignant Wounds: A Retrospective, Single-Center, Observational Study
    Nicodeme, Marguerite
    Dureau, Sylvain
    Cheron, Maxime
    Kriegel, Irene
    Trenchand, Melissandre
    Bauer, Pierre
    Fromantin, Isabelle
    JOURNAL OF PAIN AND SYMPTOM MANAGEMENT, 2021, 62 (01) : 134 - 140