EXTERNAL RADIATION DOSES FROM PATIENTS ADMINISTERED WITH RADIOPHARMACEUTICALS Measurements and Monte Carlo Simulation

被引:2
|
作者
Kinsara, Abdul Raheem [1 ]
Abdul-Majid, Samir [1 ]
El-Gammal, Wael [2 ]
Albaghdadi, Tarik [3 ]
Maimani, Abdulraof [3 ]
Abulfaraj, Waleed H. [1 ]
机构
[1] King Abdulaziz Univ, Fac Engn, Jeddah 21413, Saudi Arabia
[2] Permanent Radiat Safety Comm, Jeddah, Saudi Arabia
[3] King Abdulaziz Univ, Fac Med, Jeddah 21413, Saudi Arabia
来源
关键词
radiation dose; radiopharmaceuticals; MCNP; NUCLEAR-MEDICINE; HAND EXPOSURE; FAMILY-MEMBERS; I-131; EXTREMITY; STAFF; F-18;
D O I
10.2298/NTRP1403199K
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Monte Carlo simulations and dose measurements were performed for radionuclides in the whole body and trunks of different sizes in order to estimate external radiation whole body doses from patients administered with radiopharmaceuticals. Calculations were performed on cylindrical water phantoms whose height was 176 cm and for three body diameters: of 24 cm, 30 cm, and 36 cm. The investigated radionuclides were: Tc-99m, I-131, I-23, Ga-67, Tl-201, and In-111. Measured and MCNP-calculated values were 2-6 times lower than the values calculated by the point source method. Additionaly, the total dose received by the public until a radionuclide is completely disintegrated was calculated. The other purpose of this work is to provide data on whole body and finger occupational doses received by technologists working in nuclear medicine. Data showed a wide variation in doses that depended on the individual technologist and the position of the dosimeter.
引用
收藏
页码:199 / 206
页数:8
相关论文
共 50 条
  • [21] Monte Carlo Simulation of Radiation Effects in Microelectronics
    Weller, Robert A.
    Mendenhall, Marcus H.
    Reed, Robert A.
    Warren, Kevin M.
    Sierawski, Brian D.
    Schrimpf, Ronald D.
    Massengill, Lloyd W.
    Asai, Makoto
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1262 - 1268
  • [22] Monte Carlo simulations of occupational radiation doses in interventional radiology
    Siiskonen, T.
    Tapiovaara, M.
    Kosunen, A.
    Lehtinen, M.
    Vartiainen, E.
    BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (954): : 460 - 468
  • [23] A Terahertz Blackbody Radiation Standard Based on Emissivity Measurements and a Monte-Carlo Simulation
    Monte, C.
    Gutschwager, B.
    Adibekyan, A.
    Hollandt, J.
    JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2014, 35 (08) : 649 - 658
  • [24] A Terahertz Blackbody Radiation Standard Based on Emissivity Measurements and a Monte-Carlo Simulation
    C. Monte
    B. Gutschwager
    A. Adibekyan
    J. Hollandt
    Journal of Infrared, Millimeter, and Terahertz Waves, 2014, 35 : 649 - 658
  • [25] Radiation protection from external exposure to radionuclides: A Monte Carlo data handbook
    Amato, Ernesto
    Italiano, Antonio
    Auditore, Lucrezia
    Baldari, Sergio
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 46 : 160 - 167
  • [27] Voxel-based Monte Carlo simulation of human external exposure to terrestrial gamma radiation
    Bouzouita, A.
    Askri, B.
    Manai, K.
    Trabelsi, A.
    RADIOPROTECTION, 2024, 59 (04) : 296 - 305
  • [28] Scattered radiation from radiographic intensifying screen: a Monte Carlo simulation
    Barroso, RC
    Braz, D
    Anjos, MJ
    Lopes, RT
    de Castro, CRF
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS III, 2001, 4508 : 188 - 192
  • [29] Radiation doses in volume-of-interest breast computed tomography-A Monte Carlo simulation study
    Lai, Chao-Jen
    Zhong, Yuncheng
    Yi, Ying
    Wang, Tianpeng
    Shaw, Chris C.
    MEDICAL PHYSICS, 2015, 42 (06) : 3063 - 3075
  • [30] Uncertainties in personal dosimetry for external radiation: A Monte Carlo approach
    van Dijk, J. W. E.
    RADIATION PROTECTION DOSIMETRY, 2006, 121 (01) : 31 - 39