Research on Pneumatic-liquid On-Line Automatic Balance Technology for High-End Turbine Units

被引:5
|
作者
Pan, Xin [1 ,2 ]
Ge, Dehong [1 ,2 ]
Li, Wei [1 ,2 ]
Huo, Jiaji [1 ,3 ]
机构
[1] Beijing Univ Chem Technol, Minist Chem Safety Educ Engn Res Ctr, Beijing 100029, Peoples R China
[2] Beijing Univ Chem Technol, Beijing Key Lab Hlth Monitoring & Self Recovery H, Beijing 100029, Peoples R China
[3] Chengda Engn Corp China, Chengdu 500643, Peoples R China
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
high-end turbine unit; automatic balancing technology; structural optimization design; finite element simulation; FAULT-DIAGNOSIS; ROTOR;
D O I
10.3390/machines10090744
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Rotor mass imbalance is the main cause of vibration overload of high-end turbine units, which can easily induce a variety of failures such as shaft tile and seal wear, and blade breakage. The online automatic balancing system can solve the problem of imbalance of rotor mass during the operation of the equipment, and at the same time can ensure the long-term stable operation of the equipment. Therefore, a new pneumatic-liquid on-line automatic balance (PLOABS) system is proposed for high-end turbine units, which has the advantages of simple structure, no moving parts in the rotating element, closed action environment, reversible balancing process and can maintain the original state when restarted. Using ANSYS software, the gas driving force and the internal gas-liquid rotating flow field of the actuator are simulated and analyzed, and the actuator structure has been further optimized. At the same time, a set of the PLOABS system is built to conduct automatic balancing experiments. The results showed that the rotor amplitude was reduced from 18.3 to 10.6 mu m, which verified the feasibility and effectiveness of the PLOABS technology and laid the foundation for the subsequent engineering application of the PLOABS technology.
引用
收藏
页数:19
相关论文
共 32 条
  • [31] Case study and application of process analytical technology (PAT) towards bioprocessing: Use of on-line high-performance liquid chromatography (HPLC) for making real-time pooling decisions for process chromatography
    Rathore, Anurag S.
    Yu, Marcella
    Yeboah, Samuel
    Sharma, Ashutosh
    BIOTECHNOLOGY AND BIOENGINEERING, 2008, 100 (02) : 306 - 316
  • [32] Analysis of antibody-drug conjugates by comprehensive on-line two-dimensional hydrophobic interaction chromatography x reversed phase liquid chromatography hyphenated to high resolution mass spectrometry. II- Identification of sub-units for the characterization of even and odd load drug species
    Sarrut, Morgan
    Fekete, Szabolcs
    Janin-Bussat, Marie-Claire
    Colas, Olivier
    Guillarme, Davy
    Beck, Alain
    Heinisch, Sabine
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1032 : 91 - 102