Reliability of the Three-minute All-out Test for Non-motorized Treadmill Tethered Running

被引:5
|
作者
Gama, M. C. T. [1 ]
Sousa, F. A. B. [1 ]
dos Reis, I. G. M. [1 ]
Gobatto, C. A. [1 ]
机构
[1] Univ Campinas UNICAMP, Sch Appl Sci, Lab Appl Sport Physiol LAFAE, Limeira, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
ergometer; output power; strength; velocity; aerobic capacity and anaerobic capacity; CRITICAL POWER; CYCLING TEST; WORK CAPACITY; SPRINT EXERCISE; STEADY-STATE; SINGLE TEST; SCIENCE; LACTATE; PARAMETERS; ERGOMETRY;
D O I
10.1055/s-0035-1565238
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The 3-min all-out test was developed and validated on a cycle ergometer using a modification of a linear mathematical equation (1/time vs. power) obtained from the original critical power model. The purpose of this development was to obtain, in a single test, the aerobic and anaerobic capacity parameters and identify the exercise transition moment from heavy to severe intensity. The aim of this study was to propose an adaptation of the all-out 3-min cycle ergometer to a non-motorized treadmill with tethered running. In addition, we tested the reproducibility of this adapted protocol, highlighting the need for mechanical power evaluation using a specific ergometer. Consequently, 10 physically active individuals visited the laboratory 4 times for testing and data collection. The results suggested that the protocol adaptation for the 3-min all-out test for non-motorized treadmill with tethered running was reproducible and feasible. It was also possible to show that the AO(3) application in this ergometer ensures the specificity of the sports that involve the running exercise, from assessment of both aerobic and anaerobic parameters, accomplished in a single day of application.
引用
收藏
页码:613 / 619
页数:7
相关论文
共 50 条
  • [21] VALIDATION OF THE 3-MINUTE ALL-OUT EXERCISE TEST FOR SHUTTLE RUNNING PRESCRIPTION
    Saari, Anssi
    Dicks, Nathan D.
    Hartman, Mark E.
    Pettitt, Robert W.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2019, 33 (06) : 1678 - 1684
  • [22] Reliability of the Woodway Curve™ Non-Motorized Treadmill for Assessing Anaerobic Performance
    Gonzalez, Adam M.
    Wells, Adam J.
    Hoffman, Jay R.
    Stout, Jeffrey R.
    Fragala, Maren S.
    Mangine, Gerald T.
    McCormack, William P.
    Townsend, Jeremy R.
    Jajtner, Adam R.
    Emerson, Nadia S.
    Robinson, Edward H.
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2013, 12 (01) : 104 - 108
  • [23] Increased physiologic intensity during walking and running on a non-motorized, curved treadmill
    Smoliga, James M.
    Hegedus, Eric J.
    Ford, Kevin R.
    PHYSICAL THERAPY IN SPORT, 2015, 16 (03) : 262 - 267
  • [24] The Impact of Temperature on Critical Power Determined by a Three Minute All-Out Test
    Kaiser, Brendan
    Kruse, Ka'eo
    Gibson, Brandon
    Santisteban, Kelsey
    Larson, Emily
    Wilkins, Brad
    Jones, Andrew
    Halliwill, John
    Minson, Christopher
    FASEB JOURNAL, 2020, 34
  • [25] Ground Reaction Forces and Gait Parameters during Motorized and Non-Motorized Treadmill Walking and Running on the International Space Station Treadmill
    Norcross, Jason
    DeWitt, John
    Lee, Stuart M. C.
    McCleary, Frank
    Edwards, W. Brent
    Hagan, R. Donald
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S122 - S122
  • [26] Reliability and Validity of Predicted Performance in the Severe-Intensity Domain From the 3-Minute All-Out Running Test
    Busso, Thierry
    Lloria-Varella, Jaume
    Sabater-Pastor, Frederic
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2024, 19 (09) : 939 - 942
  • [27] The Effect of a Curved Non-Motorized Treadmill on Running Gait Length, Imbalance and Stride Angle
    Hatchett, Andrew
    Armstrong, Kaitlyn
    Parr, Brian
    Crews, Mallory
    Tant, Charlie
    SPORTS, 2018, 6 (03):
  • [28] Differences Among Estimates of Critical Power and Anaerobic Work Capacity Derived From Five Mathematical Models and the Three-Minute All-Out Test
    Bergstrom, Haley C.
    Housh, Terry J.
    Zuniga, Jorge M.
    Traylor, Daniel A.
    Lewis, Robert W., Jr.
    Camic, Clayton L.
    Schmidt, Richard J.
    Johnson, Glen O.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2014, 28 (03) : 592 - 600
  • [29] Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
    Flueck, Joelle L.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (124):
  • [30] Validity and Reliability of the 3-Minute All-Out Test in National and International Competitive Swimmers
    Piatrikova, Eva
    Sousa, Ana C.
    Gonzalez, Javier T.
    Williams, Sean
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2018, 13 (09) : 1190 - 1198