Permanent magnet synchronous machine demagnetisation prevention and torque estimation control considering rotor temperature

被引:12
|
作者
Ursic, Luka [1 ]
Nemec, Mitja [2 ]
机构
[1] Pipistrel Vert Solut Doo, Vipavska Cesta 2, SI-5270 Ajdovscina, Slovenia
[2] Univ Ljubljani, Fak Elektrotehn, Trzaska 25, SI-1000 Ljubljana, Slovenia
关键词
demagnetisation; machine control; synchronous machines; synchronous motors; synchronous motor drives; permanent magnet motors; rotors; angular velocity control; complete permanent magnet management solution; PMSM drive; permanent magnets; modified flux observer; precise torque estimation; temperature information; machine currents; demagnetisation model; torque estimation control; rotor temperature; MOTOR;
D O I
10.1049/iet-pel.2018.6162
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The article presents complete permanent magnet management solution for a PMSM drive. The temperature of permanent magnets is obtained with a modified flux observer. With this available data, more precise torque estimation is possible. Furthermore the temperature information along with machine currents is fed to full demagnetisation model of permanent magnets in order to obtain their state. This information is then used to limit the applied reverse field in order to prevent the demagnetisation. The algorithm has been tested with simulations as well experimentally and the results show successful prevention of demagnetisation.
引用
收藏
页码:2161 / 2169
页数:9
相关论文
共 50 条
  • [21] Proposal of a permanent magnet synchronous machine with asymmetrical rotor
    Ishikawa, Takeo
    Watanabe, Taiki
    Suzuki, Yuichiro
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2019, 59 (03) : 797 - 804
  • [22] Advanced rotor temperature estimation of permanent magnet synchronous machines for electric vehicles
    Du, Changhong
    Peng, Zhiyuan
    Ren, Yong
    Zhou, Anjian
    Ma, Yongquan
    Chen, Jian
    Deng, Tao
    ADVANCES IN MECHANICAL ENGINEERING, 2020, 12 (06)
  • [23] A New Robust Torque Control of a Five Phase Permanent Magnet Synchronous Machine
    Sari, Bilal
    Dieng, Abdoulaye
    Benkhoris, Mohamed Fouad
    Ahmed, Mourad Ait
    2012 15TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (EPE/PEMC), 2012,
  • [24] Direct torque control of a permanent magnet synchronous machine for hybrid hydraulic excavator
    Chen, Qihuai
    Lin, Tianliang
    Ren, Haoling
    IET ELECTRIC POWER APPLICATIONS, 2019, 13 (02) : 222 - 228
  • [25] Model Predictive Control of Permanent Magnet Synchronous Machine with Reduced Torque Ripple
    Hu, Hongming
    Zhu, Jianguo
    Guo, Youguang
    2013 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2013, : 1478 - 1482
  • [26] Improvement of Torque Accuracy of Interior Permanent Magnet Synchronous Motor Considering Temperature Variation
    Kang, Dongkil
    Hwang, Jaeyeob
    Lee, Geunho
    Lim, Heesun
    Jin, Wonjoon
    JOURNAL OF MAGNETICS, 2021, 26 (03) : 311 - 321
  • [27] Estimation of Rotor Temperature of Permanent Magnet Synchronous Motor Based on Model Reference Fuzzy Adaptive Control
    Ding, Hongchang
    Gong, Xiaobin
    Gong, Yuchun
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2020, 2020
  • [28] A robust control of permanent magnet synchronous motor using load torque estimation
    Kim, MS
    Song, DS
    Lee, YK
    Won, TH
    Park, HW
    Jung, YI
    Lee, MH
    Lee, H
    ISIE 2001: IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS PROCEEDINGS, VOLS I-III, 2001, : 1157 - 1162
  • [29] Cogging Torque Reduction Technique by Considering Step-skew Rotor in Permanent Magnet Synchronous Motor
    Phuong Thi Luu
    Lee, Ji-Young
    Hwang, Wook
    Woo, Byung-Chul
    2018 21ST INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2018, : 219 - 223
  • [30] A Practical Torque Estimation Method for Interior Permanent Magnet Synchronous Machine in Electric Vehicles
    Wu, Zhihong
    Lu, Ke
    Zhu, Yuan
    PLOS ONE, 2015, 10 (06):