Efficient and Comprehensive Evaluation Method of Temporary Overvoltage in Distribution Systems with Inverter-Based Distributed Generations

被引:4
|
作者
Cho, Namhun [1 ]
Lee, Moonjeong [2 ]
Yoon, Myungseok [2 ]
Choi, Sungyun [2 ]
机构
[1] Korea Elect Power Res Inst, Daejeon 34056, South Korea
[2] Korea Univ, Sch Elect Engn, Seoul 02841, South Korea
基金
新加坡国家研究基金会;
关键词
3D graph; distributed generation; effective grounding; inverter-based DG; single line-to-ground fault; temporary overvoltage (TOV);
D O I
10.3390/su13137335
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In general, a temporary overvoltage (TOV) on the healthy phases occurs because of the neutral-shift phenomenon during a single line-to-ground (SLG) fault. The TOV can destroy the insulation of electric devices and cause damage to other equipment and customer loads in just a few cycles. In practice, the TOV can be affected by numerous factors: the sequence reactance ratio of the interconnection transformer, the ratio of load to DG, and the distance to the fault. More importantly, inverter-based distributed generations (DGs) have different influences on the TOV from traditional synchronous-machine-based DGs. In this sense, this work performed an efficient and comprehensive investigation on the effect of these various parameter types and their extensive variations, based on steady-state analysis with sequence equivalent circuits and three-dimensional representations. The proposed methodology can facilitate judging the impact of multi-parameter conditions on the TOV readily and comparing the fault characteristics of synchronous-machine-based and inverter-based DGs. Finally, the results can be used for future studies on TOV mitigation techniques.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] A Hybrid Anti-islanding Method for Inverter-Based Distributed Generation
    Rokrok, Ebrahim
    Shafie-Khah, Miadreza
    Karshenas, Hamid Reza
    Rokrok, Esmail
    Catalao, Joao P. S.
    TECHNICAL INNOVATION FOR SMART SYSTEMS (DOCEIS 2017), 2017, 499 : 259 - 266
  • [32] Application of inverter-based distributed generators for harmonic damping throughout a distribution network
    Pogaku, N
    Green, TC
    2005 IEEE 36TH POWER ELECTRONIC SPECIALISTS CONFERENCE (PESC), VOLS 1-3, 2005, : 1922 - 1927
  • [33] Traveling Wave Based Method for Protecting Power Distribution Systems with Distributed Generations
    Fan, Wen
    Liao, Yuan
    2019 INTERNATIONAL ENERGY AND SUSTAINABILITY CONFERENCE (IESC), 2019,
  • [34] Multiple harmonic sources identification including inverter-based distributed generations using empirical Fourier decomposition
    Motlagh, Shayan Z. T.
    Akbari Foroud, Asghar
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (08) : 1932 - 1954
  • [35] An islanding detection methodology combining decision trees and Sandia frequency shift for inverter-based distributed generations
    Azim, Riyasat
    Li, Fangxing
    Xue, Yaosuo
    Starke, Michael
    Wang, Honggang
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (16) : 4104 - 4113
  • [36] Anti-Islanding Techniques for Inverter-Based Distributed Generation Systems - A Survey
    Guha, Bikiran
    Haddad, Rami J.
    Kalaani, Youakim
    IEEE SOUTHEASTCON 2015, 2015,
  • [37] Strength assessment of electric power systems containing inverter-based distributed generation
    Sanni, Shereefdeen Oladapo
    Akorede, Mudathir Funsho
    Olarinoye, Gbenga Abidemi
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 207
  • [38] Recloser-Fuse Coordination Protection for Inverter-Based Distributed Generation Systems
    Gutierres, L. F. de F.
    Mariotto, L.
    Cardoso, G., Jr.
    Loose, F.
    2015 50TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2015,
  • [39] An Islanding Detection Method for Inverter-Based Distributed Generators Based on the Reactive Power Disturbance
    Chen, Xiaolong
    Li, Yongli
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (05) : 3559 - 3574
  • [40] Robust hybrid anti-islanding method for inverter-based distributed generation
    Abdolrasol, Maher. G. M.
    Mekhilef, Saad