Value of 3D-TOF MR angiography and 4D-dynamic contrast-enhanced MRI in the assessment of spontaneous posterior cavernous sinus dural arteriovenous fistula

被引:0
|
作者
Caparroz Neto, Francisco Bermal [1 ]
Abud, Lucas Giansante [1 ,2 ]
Gomes de Oliveira, Rafael Gouveia [2 ]
Abud, Daniel Giansante [3 ]
Cabete Fabio, Soraia Ramos [4 ]
机构
[1] Hosp Sao Francisco, Dept Radiol & Diagnost Imagem, Ribeirao Preto, SP, Brazil
[2] Hosp Sao Lucas, Dept Radiol & Diagnost Imagem, Ribeirao Preto, SP, Brazil
[3] Univ Sao Paulo, Fac Med Ribeirao Preto, Div Neurorradiol Intervencionista, Ribeirao Preto, SP, Brazil
[4] Hosp Unimed Ribeirao Preto, Dept Neurol, Ribeirao Preto, SP, Brazil
关键词
VENOUS DRAINAGE;
D O I
10.1590/0004-282X-ANP-2020-0341
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
[No abstract available]
引用
收藏
页码:559 / 560
页数:2
相关论文
共 50 条
  • [11] The Use of 3 D Contrast Enhanced Magnetic Resonance (MR) -Angiography To Detect Spinal Dural AV Fistula
    Jani, Vishal
    Razak, Anmar
    DeMarco, Kevin
    Hussain, Syed
    NEUROLOGY, 2013, 80
  • [12] What is the optimal dose of Gd-DTPA in aortic blood during contrast enhanced 3D-TOF MR angiography?
    Chung, TS
    Lee, DH
    Hong, KS
    Chien, D
    Frenzel, T
    Weinmann, HJ
    RADIOLOGY, 1997, 205 : 669 - 669
  • [13] The role of time-resolved 3D contrast-enhanced MR angiography in the assessment and grading of cerebral arteriovenous malformations
    Oleaga, L.
    Dalal, S. S.
    Weigele, J. B.
    Hurst, R. W.
    Lee, J.
    Voorhees, A.
    Melhem, E. R.
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (03) : E118 - E122
  • [14] Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of Dural Arteriovenous Fistula
    Jinhee Jang
    Peter Schmitt
    Bom-yi Kim
    Hyun Seok Choi
    So-Lyung Jung
    Kook-Jin Ahn
    Inseong Kim
    Munyoung Paek
    Bum-soo Kim
    Neuroradiology, 2014, 56 : 305 - 314
  • [15] Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of Dural Arteriovenous Fistula
    Jang, Jinhee
    Schmitt, Peter
    Kim, Bom-yi
    Choi, Hyun Seok
    Jung, So-Lyung
    Ahn, Kook-Jin
    Kim, Inseong
    Paek, Munyoung
    Kim, Bum-soo
    NEURORADIOLOGY, 2014, 56 (04) : 305 - 314
  • [16] Cerebral arteriovenous malformations (AVMs): Morphologic evaluation by ultrashort 3D contrast-enhanced MR angiography
    Essig, M
    Schoenberg, SO
    Knopp, MV
    Debus, J
    Lohr, F
    VanKaick, G
    RADIOLOGY, 1997, 205 : 1136 - 1136
  • [17] 4D Radial Acquisition Contrast-Enhanced MR Angiography and Intracranial Arteriovenous Malformations Quickly Approaching Digital Subtraction Angiography
    Eddleman, Christopher S.
    Jeong, Hyun J.
    Hurley, Michael C.
    Zuehlsdorff, Sven
    Dabus, Guilherme
    Getch, Christopher G.
    Batjer, H. Hunt
    Bendok, Bernard R.
    Carroll, Timothy J.
    STROKE, 2009, 40 (08) : 2749 - 2753
  • [18] Surveillance of Unruptured Intracranial Saccular Aneurysms Using Noncontrast 3D-Black-Blood MRI: Comparison of 3D-TOF and Contrast-Enhanced MRA with 3D-DSA
    Zhu, C.
    Wang, X.
    Eisenmenger, L.
    Tian, B.
    Liu, Q.
    Degnan, A. J.
    Hess, C.
    Saloner, D.
    Lu, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (06) : 960 - 966
  • [19] 3D contrast-enhanced MR angiography of the run-off vessels: Value of image subtraction
    Ruehm, SG
    Nanz, D
    Baumann, A
    Schmid, M
    Debatin, JF
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (03) : 402 - 411
  • [20] Evaluating the diagnostic accuracy of 3D contrast-enhanced magnetic resonance angiography versus digital subtraction angiography in spinal dural arteriovenous fistulas
    Khalafallah, Adham M.
    Tigre, Joseph Yunga
    Rady, Nadine
    Starke, Robert M.
    Saraf-Lavi, Efrat
    Levi, Allan D.
    NEUROSURGICAL FOCUS, 2024, 56 (03)