Magnetic resonance imaging in patients with cardiac pacemakers: In vitro and in vivo evaluation at 0.5 Tesla.

被引:26
|
作者
Sommer, T
Lauck, G
Schimpf, R
von Smekal, A
Wolke, S
Block, W
Gieseke, J
Schneider, C
Funke, HD
Schild, H
机构
[1] Univ Bonn, Radiol Klin, D-53127 Bonn, Germany
[2] Krankenhaus Marienhof, Koblenz, Germany
[3] Univ Bonn, Med Klin & Poliklin, D-5300 Bonn, Germany
[4] Univ Munich, Radiol Klin, Munich, Germany
[5] Univ Bonn, Inst Strahlen & Kernphys, D-5300 Bonn, Germany
[6] Philips Med Syst, Hamburg, Germany
[7] Univ Bonn, Klin Herz & Gefasschirurg, D-5300 Bonn, Germany
关键词
MRI; cardiac pacemakers; metal implants;
D O I
10.1055/s-2007-1015179
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: MRI is currently regarded as absolutely contraindicated in patients with implanted cardiac pacemakers. In this prospective study safety and feasibility of MRI in patients with new generation pacemakers (PM) was evaluated in vitro and in vivo. Methods: 14 PM models in vitro and 18 patients with implanted new generation PM underwent a MRI exam at 0.5 Tesla with standard spin, turbo spin, and gradient echo (FFE) sequences under continuous EGG-monitoring. PM inquiry was performed before and after the MRI exam, including assessment of stimulation thresholds. Results: In the static magnetic field all PM switched to the asynchronous mode due to activation of the Reed switch, resulting in continuous pacing at a fixed rate. In three PM models in vitro, however, after activation of the Reed switch, there was a software-induced switch back to the demand mode. In these PM inhibition and triggering were observed after starting the MRI scan due to influence of the pulsed magnetic fields. PM program changes, damage of PM components, dislocation/torque of the PM and rapid pacing of the PM were observed neither in vitro nor in vivo. Atrial and ventricular stimulation thresholds remained unchanged. Conclusion: MRI at 0.5 Tesla should not be regarded as absolutely contraindicated in patients with implanted new generation PM. However, knowledge of the behaviour of the specific PM model in static and pulsed magnetic fields is required, if necessary also changes of the PM program prior to the MRI exam, continuous ECG monitoring and cardiological stand-by.
引用
收藏
页码:36 / 43
页数:8
相关论文
共 50 条
  • [11] Saftey of magnetic resonance imaging in patients with cardiac pacemakers: A prospective study in 115 patients at 1.5 Tesla
    Becker, Alexander
    Muehling, Olaf
    Hinterseer, Martin
    Morhard, Dominilk
    Relthmann, Christopher
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A3 - A3
  • [12] Magnetic resonance imaging of the brain in patients with cardiac pace makers.: In-vitro- and in-vivo-evaluation at 1.5 Tesla
    Schmiedel, A
    Hackenbroch, M
    Yang, A
    Nähle, CP
    Skowasch, D
    Meyer, C
    Schimpf, R
    Schild, H
    Sommer, T
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (05): : 731 - 744
  • [13] MRI and cardiac pacemakers: In vitro evaluation and in vivo studies in 51 patients at 0.5 T
    Sommer, T
    Vahlhaus, C
    Reinke, M
    Steffens, M
    Hofer, U
    Kader, R
    RADIOLOGY, 2000, 217 : 291 - 291
  • [14] Magnetic resonance imaging in patients with cardiac pacemakers - Reply
    Martin, ET
    Coman, JA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (03) : 562 - 562
  • [15] Safety of cardiac pacemakers and ICDs on magnetic resonance imaging: testing the functioning of these devices at 1.5 tesla
    Nordbeck, P.
    Bauer, W. R.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2008, 133 (13) : 624 - 628
  • [16] Uses and potential for cardiac magnetic resonance imaging in patients with cardiac resynchronisation pacemakers
    Koshy, Aaron
    Witte, Klaus
    EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (06) : 445 - 450
  • [17] Magnetic resonance imaging of the human spine and spinal cord at 3 tesla. A technical note
    Riccioli, LA
    Marliani, AF
    Ghedin, P
    Clementi, V
    Agati, R
    Cevolani, D
    Leonardi, M
    RIVISTA DI NEURORADIOLOGIA, 2005, 18 (5-6): : 606 - 616
  • [18] Cardiac Magnetic Resonance Imaging at 7 Tesla
    Stab, Daniel
    Al Najjar, Aiman
    O'Brien, Kieran
    Strugnell, Wendy
    Richer, Jonathan
    Rieger, Jan
    Niendorf, Thoralf
    Barth, Markus
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (143):
  • [19] Evaluation of a safety protocol for clinically indicated magnetic resonance imaging of patients with permanent pacemakers and implantable defibrillators at 1.5 tesla
    Nazarjan, S
    Roguin, A
    Zviman, MM
    Lardo, AC
    Dickfeld, TL
    Berger, RD
    Bluemke, DA
    Halperin, HR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 14A - 14A
  • [20] The neural correlates of working memory components: A functional magnetic resonance imaging study at 3 Tesla.
    Gruber, O
    Bublak, P
    Schubert, T
    von Cramon, DY
    JOURNAL OF COGNITIVE NEUROSCIENCE, 1999, : 32 - 33