Standardization of HbA1c: good or bad?

被引:6
|
作者
Marshall, Sally M. [1 ]
机构
[1] Newcastle Univ, Diabet Res Grp, Inst Cellular Med, Fac Clin Med Sci, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
关键词
GLYCATED HEMOGLOBIN; DIABETES CONTROL; COMPLICATIONS;
D O I
10.1038/nrendo.2010.66
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The development of a true reference measurement system by the International Federation for Clinical Chemistry (IFCC) for the first time allows reporting of true HbA(1c) results, standardized to an absolute value, worldwide. Regression equations between the IFCC assay and current harmonization assays, including the Diabetes Control and Complications Trial (DCCT) assay, are linear, tight, and stable over time. National and international setting of targets, audit and benchmarking of services will be easier than before, as will translation of research into clinical practice. Nevertheless, the main disadvantage of the IFCC assay is that the numbers and units reported (mmol/mol) are very different from the DCCT value (percentage). An extensive education program for patients and health-care professionals is, therefore, needed to prevent confusion and consequent deterioration in glycemic control. Furthermore, the IFCC system does not overcome difficulties inherent in the measurement and interpretation of HbA(1c), such as in the presence of abnormal turnover of red blood cells and hemoglobinopathies.
引用
收藏
页码:408 / 411
页数:4
相关论文
共 50 条
  • [31] HbA1c measurement
    Kilpatrick, ES
    JOURNAL OF CLINICAL PATHOLOGY, 2004, 57 (04) : 344 - 345
  • [32] Use of HbA1c Trajectory Clusters to Generate Individualized HbA1c Targets
    Karpati, Tomas
    Feldman, Becca
    Hoshen, Moshe
    Balicer, Ran
    Curtis, Bradley H.
    Ho, Xuanyao
    Rubin, Gil
    Strizek, Alena
    Leventer-Roberts, Maya
    DIABETES, 2017, 66 : A434 - A435
  • [33] DIALYSIS OF HBA1C
    GOLDSTEIN, DE
    DIABETES CARE, 1982, 5 (04) : 454 - 455
  • [34] Variation of Measured HbA1c from Predicted HbA1c on Freestyle Libre
    Muthabathula, Jayasri
    Grixti, Lydia
    Fletcher-Salt, Tamsin
    Nayak, Ananth U.
    DIABETES, 2020, 69
  • [35] Vom HbA1c zum GesamtrisikoParadigmenwechselFrom HbA1c to total riskParadigm change
    T. Uebel
    Der Diabetologe, 2014, 10 (3): : 217 - 222
  • [36] Change in HbA1c concentration as decision parameter for frequency of HbA1c measurement
    Munk, Jens K.
    Lind, Bent S.
    Jorgensen, Henrik L.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2019, 79 (05): : 320 - 324
  • [37] Global and national harmonization and standardization of clinical laboratory testings: The example of HbA1c
    Aslan, Diler
    Yilmazturk, Gamze Can
    Akalin, Nalan
    Buyukbese, Mehmet Akif
    Sermez, Yurdaer
    Fenkci, Semin
    TURKISH JOURNAL OF BIOCHEMISTRY-TURK BIYOKIMYA DERGISI, 2011, 36 (04): : 374 - 383
  • [38] The interference by HbF on HbA1c (BM Test HbA1c) measurement in enzymatic method
    Nitta, Takenori
    Yamashiro, Yasuhiro
    Hattori, Yukio
    Ezumi, Tomoko
    Nishioka, Mituaki
    Nakamura, Junji
    ANNALS OF CLINICAL BIOCHEMISTRY, 2015, 52 (05) : 569 - 575
  • [39] The True Value of HbA1c as a Predictor of Diabetic Complications: Simulations of HbA1c Variables
    Lind, Marcus
    Oden, Anders
    Fahlen, Martin
    Eliasson, Bjorn
    PLOS ONE, 2009, 4 (02):
  • [40] HbA1c and Glucose Management Indicator relationship: can HbA1c determination be avoided?
    Navarro Moreno, Constanza
    Sanchez Ruiz, Daniel
    Garcia Garcia, Emilio Jose
    Marchueta Elizagarate, Izaskun
    Gomez Gila, Ana Lucia
    HORMONE RESEARCH IN PAEDIATRICS, 2021, 94 (SUPPL 1): : 234 - 235