Exploratory study of the association of volumetric modulated arc therapy (VMAT) plan robustness with local failure in head and neck cancer

被引:15
|
作者
Liu, Wei [1 ]
Patel, Samir H. [1 ]
Harrington, Daniel P. [1 ]
Hu, Yanle [1 ]
Ding, Xiaoning [1 ]
Shen, Jiajian [1 ]
Halyard, Michele Y. [1 ]
Schild, Steven E. [1 ]
Wong, William W. [1 ]
Ezzell, Gary E. [1 ]
Bues, Martin [1 ]
机构
[1] Mayo Clin, Dept Radiat Oncol, Phoenix, AZ 85054 USA
来源
关键词
head and neck cancer; local failure; plan robustness; uncertainty; VMAT; SETUP UNCERTAINTIES; RADIATION-THERAPY; IMRT; RADIOTHERAPY; PATTERNS; IMPACT; PROBABILITY; MARGINS; ERRORS; TUMORS;
D O I
10.1002/acm2.12099
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work is to show which is more relevant to cause local failures (LFs) due to patient setup uncertainty between the planning target volume (PTV) underdosage and the potential target underdosage subject to patient setup uncertainties in head and neck (H&N) cancer treated with volumetric-modulated arc therapy (VMAT). Thirteen LFs in 10 H&N patients treated by VMAT were analyzed. Measures have been taken to minimize the chances of insufficient target delineation for these patients and the patients were clinically determined to have LF based on the PET/CT scan results by an experienced radiologist and then reviewed by a second experienced radiation oncologist. Two methods were used to identify the possible locations of LF due to underdosage: (a) examining the standard VMAT plan, in which the underdosed volume in the nominal dose distribution (UVN) was generated by subtracting the volumes receiving the prescription doses from PTVs, and (b) plan robustness analysis, in which in addition to the nominal dose distribution, six perturbed dose distributions were created by translating the CT iso-center in three cardinal directions by the PTV margin. The coldest dose distribution was represented by the minimum of the seven doses in each voxel. The underdosed volume in the coldest dose distribution (UVC) was generated by subtracting the volumes receiving the prescription doses in the coldest dose distribution from the volumes receiving the prescription doses in the nominal dose distribution. UVN and UVC were subsequently examined for spatial association with the locations of LF. The association was tested using the binominal distribution and the Fisher's exact test of independence. We found that of 13 LFs, 11 were associated with UVCs (P = 0.011), while three were associated with UVNs (P = 0.99). We concluded that the possible target underdosage due to patient setup uncertainties appeared to be a more relevant factor associated with LF in VMAT for H&N cancer than the compromised PTV coverage at least for the patients included in this study.
引用
收藏
页码:76 / 83
页数:8
相关论文
共 50 条
  • [21] Impact of Parameters for Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer
    Runxiao, L.
    Yankun, C.
    Rong, Q.
    Yuzhi, S.
    Kai, S.
    Mingchang, M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3439 - 3439
  • [22] Volumetric modulated arc therapy (VMAT) in the treatment of esophageal cancer patients
    Stefania Martini
    Francesca Arcadipane
    Paolo Strignano
    Rosella Spadi
    Viviana Contu
    Christian Fiandra
    Riccardo Ragona
    Giorgia Catalano
    Maria Antonietta Satolli
    Michele Camandona
    Renato Romagnoli
    Umberto Ricardi
    Pierfrancesco Franco
    Medical Oncology, 2018, 35
  • [23] VAGINAL SPARING WITH VOLUMETRIC MODULATED ARC THERAPY (VMAT) FOR RECTAL CANCER
    Boulet, Scott
    Bashir, Bashir
    Bucher, Oliver
    VanUytven, Eric
    Ioculano, John
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 : S69 - S69
  • [24] Early clinical experience with volumetric modulated arc therapy in head and neck cancer patients
    Scorsetti, Marta
    Fogliata, Antonella
    Castiglioni, Simona
    Bressi, Caterina
    Bignardi, Mario
    Navarria, Piera
    Mancosu, Pietro
    Cozzi, Luca
    Pentimalli, Sara
    Alongi, Filippo
    Santoro, Armando
    RADIATION ONCOLOGY, 2010, 5
  • [25] Impact of shoulder deformation on volumetric modulated arc therapy doses for head and neck cancer
    Tachiban, Hidenobu
    Motegi, Kana
    Moriya, Shunsuke
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 53 : 118 - 128
  • [26] Early clinical experience with volumetric modulated arc therapy in head and neck cancer patients
    Marta Scorsetti
    Antonella Fogliata
    Simona Castiglioni
    Caterina Bressi
    Mario Bignardi
    Piera Navarria
    Pietro Mancosu
    Luca Cozzi
    Sara Pentimalli
    Filippo Alongi
    Armando Santoro
    Radiation Oncology, 5
  • [27] Automatic interactive optimization for volumetric modulated arc therapy planning of head and neck cancer
    Tol, J.
    Dahele, M.
    Doornaert, P.
    Slotman, B. J.
    Verbakel, W. F. A. R.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S35 - S35
  • [28] Multi-institutional evaluation of knowledge-based planning performance of volumetric modulated arc therapy (VMAT) for head and neck cancer
    Kamima, Tatsuya
    Ueda, Yoshihiro
    Fukunaga, Jun-ichi
    Shimizu, Yumiko
    Tamura, Mikoto
    Ishikawa, Kazuki
    Monzen, Hajime
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 174 - 181
  • [29] VOLUMETRIC MODULATED ARC THERAPY(VMAT) FOR THE TREATMENT OF LOCALIZED PROSTATE CANCER
    Shiraishi, Kenshiro
    Yamamoto, Kentaro
    Haga, Akihiro
    Sakumi, Akira
    Nomoto, Akihiro
    Nakagawa, Keiichi
    ANNALS OF ONCOLOGY, 2014, 25
  • [30] Volumetric modulated arc therapy (VMAT) in the treatment of esophageal cancer patients
    Martini, Stefania
    Arcadipane, Francesca
    Strignano, Paolo
    Spadi, Rosella
    Contu, Viviana
    Fiandra, Christian
    Ragona, Riccardo
    Catalano, Giorgia
    Satolli, Maria Antonietta
    Camandona, Michele
    Romagnoli, Renato
    Ricardi, Umberto
    Franco, Pierfrancesco
    MEDICAL ONCOLOGY, 2018, 35 (12)