A DNA electrochemical sensor based on nanogold-modified poly-2,6-pyridinedicarboxylic acid film and detection of PAT gene fragment

被引:101
|
作者
Yang, Jie [1 ]
Yang, Tao [1 ]
Feng, Yuanyuan [1 ]
Jiao, Kui [1 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
基金
中国国家自然科学基金;
关键词
2,6-pyridinedicarboxylic acid; gold nanoparticle; DNA electrochemical biosensor; PAT transgene; cyclic voltammetry; electrochemical impedance spectroscopy;
D O I
10.1016/j.ab.2006.12.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new DNA electrochemical biosensor is described for electrochemical impedance spectroscopy (EIS) detection of the sequence-specific DNA related to PAT transgene in the transgenic plants. Poly-2,6-pyridinedicarboxylic acid film (PDC) was fabricated by electropolymerizing 2,6-pyridinedicarboxylic acid on the glassy carbon electrode (GCE). The gold nanoparticles (NG) were modified on the PDC/ GCE to prepare NG/PDC/GCE, and then DNA probe (ssDNA) was immobilized on the NG/PDC/GCE by the interaction of NG with DNA. The immobilization of NG and the immobilization and hybridization of DNA probe were characterized with differential pulse voltammetry (DPV) and cyclic voltammetry (CV) using methylene blue (MB) as indicator and EIS. MB had a couple of well-defined CV peaks at the NG/PDC/GCE, and these redox peak currents increased after the immobilization of the DNA probe. After the hybridization of the DNA probe with the complementary single-stranded DNA (cDNA), the redox peak currents of MB decreased greatly. The electron transfer resistance (R-et) of the electrode surface in EIS in [Fe(CN)(6)](3-/4-) solution increased after the immobilization of the DNA probe on the NG/PDC/GCE. The hybridization of the DNA probe with cDNA made R-et increase further. EIS was used for the label-free detection of the target DNA. The NG modified on the PDC dramatically enhanced the immobilization amount of the DNA probe and greatly improved the sensitivity of DNA detection. The difference between the R-et value at the ssDNA/NG/PDC/GCE and that at hybridization DNA-modified electrode (dsDNA/NG/PDC/GCE) was used as the signal for detecting the PAT gene fragment with the dynamic range from 1.0 X 10(-10) to 1.0 X 10(-5) mol/L. A detection limit of 2.4 x 10(-11) mol/L could be estimated. (c) 2007 Published by Elsevier Inc.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 44 条
  • [21] DNA hybridization and phosphinothricin acetyltransferase gene sequence detection based on zirconia/nanogold film modified electrode
    Zhang, Wei
    Yang, Tao
    Jiang, Chen
    Jiao, Kui
    APPLIED SURFACE SCIENCE, 2008, 254 (15) : 4750 - 4756
  • [22] A DNA electrochemical sensor with poly-L-lysine/single-walled carbon nanotubes films and its application for the highly sensitive EIS detection of PAT gene fragment and PCR amplification of NOS gene
    Jiang, Chen
    Yang, Tao
    Jiao, Kui
    Gao, Hongwei
    ELECTROCHIMICA ACTA, 2008, 53 (06) : 2917 - 2924
  • [23] Voltammetric Sensor Based on Electrodes Modified by Poly(vinyl alcohol)-Natural Clay Film, for the Detection of Gallic Acid
    Valery, Hambate G.
    Chtaini, Abdelilah
    Loura, Benoit
    PORTUGALIAE ELECTROCHIMICA ACTA, 2019, 37 (05) : 327 - 333
  • [24] Electrochemical Sensor for Simultaneous Determination of Theophylline and Caffeine Based on a Novel poly (folic acid)/graphene Composite Film Modified Electrode
    Shu, Xiaoli
    Bian, Feng
    Wang, Qianqian
    Qin, Xiaofei
    Wang, Yan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (05): : 4251 - 4264
  • [25] Electrochemical sensor for detecting both oxidizing and reducing compounds based on poly(ethyleneimine)/phosphotungstic acid multilayer film modified electrode
    Xu, Jie
    Xu, Shimei
    Feng, Shun
    Hao, Yanjun
    Wang, Jide
    ELECTROCHIMICA ACTA, 2015, 174 : 706 - 711
  • [26] Electrochemical sensor based on a poly(para-aminobenzoic acid) film modified glassy carbon electrode for the determination of melamine in milk
    Liu, Ya Ting
    Deng, Jian
    Xiao, Xi Lin
    Ding, Li
    Yuan, Ya Li
    Li, Hui
    Li, Xiu Ting
    Yan, Xiao Na
    Wang, Li Li
    ELECTROCHIMICA ACTA, 2011, 56 (12) : 4595 - 4602
  • [27] Label-Free Femtomolar Detection of Target DNA by Impedimetric DNA Sensor Based on Poly(pyrrole-nitrilotriacetic acid) Film
    Baur, Jessica
    Gondran, Chantal
    Holzinger, Michael
    Defrancq, Eric
    Perrot, Hubert
    Cosnier, Serge
    ANALYTICAL CHEMISTRY, 2010, 82 (03) : 1066 - 1072
  • [28] Selective determination of dopamine and uric acid using electrochemical sensor based on poly(alizarin yellow R) film-modified electrode
    Zhou, Yuanzhen
    Tang, Weimin
    Wang, Jing
    Zhang, Guo
    Chai, Shouning
    Zhang, Liang
    Liu, Ting
    ANALYTICAL METHODS, 2014, 6 (10) : 3474 - 3481
  • [29] A Simple and Novel Electrochemical Sensor Based on Phosphomolybdic-Polypyrrole Film Modified Electrode for Highly Sensitive Detection of Cholic Acid
    Fan, Lifang
    Tian, Xinxin
    Shuang, Shaomin
    Dong, Chuan
    CHINESE JOURNAL OF CHEMISTRY, 2016, 34 (11) : 1177 - 1182
  • [30] An electrochemical sensor based on single-stranded DNA-poly(sulfosalicylic acid) composite film for simultaneous determination of adenine, guanine, and thymine
    Feng, Li-Jun
    Zhang, Xiu-Hua
    Liu, Ping
    Xiong, Hua-Yu
    Wang, Sheng-Fu
    ANALYTICAL BIOCHEMISTRY, 2011, 419 (02) : 71 - 75