A ratiometric sensor for dissolved oxygen in seawater

被引:5
|
作者
Poteau, X [1 ]
MacCraith, B [1 ]
机构
[1] Dublin City Univ, Natl Ctr Sensor Res, Dublin, Ireland
关键词
optical sensor; dissolved oxygen; seawater; fluorescence; ruthenium; ratiometric sensor;
D O I
10.1117/12.464211
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A dissolved oxygen sensor for marine application is reported which is based on a ratiometric approach to the fluorescence intensity quenching of the ruthenium dye [Ru(II)-tris(4,7-diphenyl-1,10-phenanthroline)](2+). Both the ruthenium complex and the coumarin derivative dye have been entrapped in a porous sol-gel film. The membrane shows good optical response on exposure to low levels of dissolved oxygen in seawater. The design and limitations of such an optode membrane are discussed.
引用
收藏
页码:886 / 893
页数:8
相关论文
共 50 条
  • [41] Ratiometric Sensor Based on PtOEP-C6/Poly (St-TFEMA) Film for Automatic Dissolved Oxygen Content Detection
    Zhang, Honglin
    Zhang, Zhiguo
    SENSORS, 2020, 20 (21) : 1 - 11
  • [42] A procedure for measuring the metrological performance of a dissolved oxygen sensor
    Rodionov A.K.
    Thermal Engineering, 2009, 56 (7) : 535 - 539
  • [43] IMPLEMENTATION OF A NEW HIGH PRECISION DISSOLVED OXYGEN SENSOR
    Xu, Zhanwei
    Zheng, Guilin
    INTERNATIONAL SYMPOSIUM ON COMPUTER SCIENCE & TECHNOLOGY: PROCEEDINGS, 2012, : 198 - 201
  • [44] Dissolved Oxygen MEMS Sensor With Enhanced Sensing Current
    Nosrati, Mehdi
    Vieira, Daniela
    Nabavi, Seyedfakhreddin
    Harvey, Edward J.
    Merle, Geraldine E.
    Bhadra, Sharmistha
    IEEE SENSORS LETTERS, 2020, 4 (05)
  • [45] An optrode type sensor to measure dissolved oxygen in water
    Campo, JC
    Pérez, MA
    González, M
    Ferrero, FJ
    IMTC/99: PROCEEDINGS OF THE 16TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS. 1-3, 1999, : 1537 - 1540
  • [46] Optrode type sensor to measure dissolved oxygen in water
    Campo, J.C.
    Perez, M.A.
    Gonzalez, M.
    Ferrero, F.J.
    Conference Record - IEEE Instrumentation and Measurement Technology Conference, 1999, 3 : 1537 - 1540
  • [47] Study on Polarization Parameters of Micro Dissolved Oxygen Sensor
    Chen, Juan
    Liu, Xiangyu
    Zheng, Zhi-cheng
    2020 CHINESE AUTOMATION CONGRESS (CAC 2020), 2020, : 5556 - 5560
  • [48] STOPPED-FLOW SENSOR FOR DISSOLVED-OXYGEN
    WANG, J
    SARIN, L
    ANALYTICA CHIMICA ACTA, 1982, 134 (JAN) : 239 - 245
  • [49] Microfabricated solid-state dissolved oxygen sensor
    McLaughlin, GW
    Braden, K
    Franc, B
    Kovacs, GTA
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 83 (1-3) : 138 - 148
  • [50] Robust Dual Optical Sensor for pH and Dissolved Oxygen
    Wang, Lu
    Jensen, Kim
    Hatzakis, Nikos
    Zhang, Min
    Sorensen, Thomas Just
    ACS SENSORS, 2022, 7 (05) : 1506 - 1513