A ratiometric sensor for dissolved oxygen in seawater

被引:5
|
作者
Poteau, X [1 ]
MacCraith, B [1 ]
机构
[1] Dublin City Univ, Natl Ctr Sensor Res, Dublin, Ireland
关键词
optical sensor; dissolved oxygen; seawater; fluorescence; ruthenium; ratiometric sensor;
D O I
10.1117/12.464211
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A dissolved oxygen sensor for marine application is reported which is based on a ratiometric approach to the fluorescence intensity quenching of the ruthenium dye [Ru(II)-tris(4,7-diphenyl-1,10-phenanthroline)](2+). Both the ruthenium complex and the coumarin derivative dye have been entrapped in a porous sol-gel film. The membrane shows good optical response on exposure to low levels of dissolved oxygen in seawater. The design and limitations of such an optode membrane are discussed.
引用
收藏
页码:886 / 893
页数:8
相关论文
共 50 条
  • [1] Use of an optical oxygen sensor to measure dissolved oxygen in seawater
    Hiroshi Hasumoto
    Tsuneo Imazu
    Toshiaki Miura
    Kazuhiro Kogure
    Journal of Oceanography, 2006, 62 : 99 - 103
  • [2] Use of an optical oxygen sensor to measure dissolved oxygen in seawater
    Hasumoto, H
    Imazu, T
    Miura, T
    Kogure, K
    JOURNAL OF OCEANOGRAPHY, 2006, 62 (01) : 99 - 103
  • [3] Ratiometric optical fiber sensor for dual sensing of copper ion and dissolved oxygen
    Chu, Cheng-Shane
    Chuang, Chih-Yung
    APPLIED OPTICS, 2015, 54 (36) : 10659 - 10665
  • [4] Ratiometric Optical Fiber Dissolved Oxygen Sensor Based on Fluorescence Quenching Principle
    Zhao, Yongkun
    Zhang, Hongxia
    Jin, Qingwen
    Jia, Dagong
    Liu, Tiegen
    SENSORS, 2022, 22 (13)
  • [5] Study on Ratiometric Optical Fiber Dissolved Oxygen Sensor Based on Fluorescence Quenching Principle
    Qing-yang, Meng
    Zhang, Hong-xia
    Zhao, Yong-kun
    Jia, Da-gong
    Liu, Tie-gen
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44 (09) : 2445 - 2449
  • [6] A novel sensor based on the porous plastic probe for determination of dissolved oxygen in seawater
    Guo, Liangqia
    Ni, Qinyan
    Li, Jiaqian
    Zhang, Lan
    Lin, Xucong
    Xie, Zenghong
    Chen, Guonan
    TALANTA, 2008, 74 (04) : 1032 - 1037
  • [7] RESEARCH ON DETERMINATION OF DISSOLVED OXYGEN IN SEAWATER
    张荣坤
    罗颖华
    ActaOceanologicaSinica, 1982, (01) : 62 - 70
  • [8] Amperometric sensor for monitoring of dissolved carbon dioxide in seawater
    Ishiji, T
    Chipman, DW
    Takahashi, T
    Takahashi, K
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) : 265 - 269
  • [9] TITRATION APPARATUS FOR DETERMINATION OF DISSOLVED-OXYGEN IN SEAWATER
    LEVY, EM
    CUNNINGHAM, CC
    CONRAD, CDW
    MOFFATT, JD
    JOURNAL OF THE FISHERIES RESEARCH BOARD OF CANADA, 1977, 34 (11): : 2218 - 2220
  • [10] Development of a neural network model for dissolved oxygen in seawater
    Palani, Sundarambal
    Liong, Shie-Yui
    Tkalich, Pavel
    Palanichamy, Jegathambal
    INDIAN JOURNAL OF MARINE SCIENCES, 2009, 38 (02): : 151 - 159