Optimized mass flux ratio of double-flow solar air heater with EHD

被引:15
|
作者
Kasayapanand, N. [1 ]
Klatsinroat, T.
机构
[1] King Mongkuts Univ Technol Thonburi, Sch Energy Environm & Mat, Bangkok 10140, Thailand
[2] Chiang Mai Univ, Dept Mech, Chiang Mai 50200, Thailand
关键词
electrohydrodynamic; computational fluid dynamics; solar air heater; heat transfer enhancement;
D O I
10.1016/j.energy.2006.11.001
中图分类号
O414.1 [热力学];
学科分类号
摘要
The numerical study of laminar forced convection inside double-flow solar air heater with electrohydrodynamic technique is investigated by finite difference method. The electric field is generated by the wire electrodes charged with DC high voltage. The mathematical modeling of computational fluid dynamics includes the interactions among electric field, flow field, and temperature field. It can be perceived that augmented heat transfer with presence of an electric field increases with the supplied voltage but decreases with the total mass flux. The optimized mass flux ratio is expressed incorporating with concerning parameter comprising of the electrode arrangement, the number of electrodes, the total heat flux at an absorbing plate, and the channel geometry. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1343 / 1351
页数:9
相关论文
共 50 条
  • [41] Energy and exergy analysis in double-pass solar air heater
    P VELMURUGAN
    R KALAIVANAN
    Sādhanā, 2016, 41 : 369 - 376
  • [42] Transient Analysis of Double Pass Solar Air Heater with Porous Media
    Theeran, Md. Yusof
    Othman, Mohd. Yusof bin Hj.
    bin Yatim, Baharudin
    bin Sopian, Kamarulzaman
    bin Roslan, Mohd. Hafidz
    Zaharim, Azami
    RES 08: PROCEEDINGS OF THE 2ND WSEAS/IASME INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY SOURCES, 2008, : 97 - 104
  • [43] Effect of air mass flow rate on the performance of a mixed-mode active solar crop dryer with a transpired air heater
    Kuhe, A.
    Ibrahim, S.
    Tuleun, L. T.
    Akanji, S. A.
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2019, 43 (01) : 531 - 538
  • [44] Mass spectrometric monitoring of fragments of organic compounds in a double-flow glow discharge cell
    Moon, HM
    Kim, K
    Lee, SC
    Kim, H
    MICROCHEMICAL JOURNAL, 1999, 63 (01) : 172 - 186
  • [45] The effect of using transverse fins on a double pass flow solar air heater using wire mesh as an absorber
    El-khawajah, M. F.
    Aldabbagh, L. B. Y.
    Egelioglu, F.
    SOLAR ENERGY, 2011, 85 (07) : 1479 - 1487
  • [46] Double Duct Packed Bed Solar Air Heater Under Combined Single and Recyclic Double Air Pass
    Singh, Satyender
    Dhiman, Prashant
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (01):
  • [47] EMPLOYING EXERGY-OPTIMIZED PIN FINS IN THE DESIGN OF AN ABSORBER IN A SOLAR AIR HEATER
    Nwosu, Nwachukwu P.
    HT2009: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE 2009, VOL 1, 2009, : 271 - 277
  • [48] Employing exergy-optimized pin fins in the design of an absorber in a solar air heater
    Nwosu, Nwachukwu P.
    ENERGY, 2010, 35 (02) : 571 - 575
  • [49] Numerical investigation of flow through an artificially roughened solar air heater
    Yadav, Anil Singh
    Bhagoria, J. L.
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2015, 36 (02) : 87 - 100
  • [50] THERMAL PERFORMANCE STUDY OF A SOLAR AIR HEATER WITH PACKED FLOW PASSAGE
    DEMIREL, Y