Novel long-term implantable blood pressure monitoring system with reduced baseline drift

被引:0
|
作者
Cong, Peng [1 ]
Young, Darrin J. [1 ]
Hoit, Brian [2 ]
Ko, Wen H. [1 ]
机构
[1] Case Western Reserve Univ, Dept Comp Sci & Elect Engn, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Sch Med, Cleveland, OH 10900 USA
来源
2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15 | 2006年
基金
美国国家科学基金会;
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel long-term less-invasive blood pressure monitoring system with fluid-filled cuff is proposed for advanced biological research. The system employs an instrumented elastic cuff attached with a rigid isolation ring on the outside wall of the cuff. The cuff is wrapped around a blood vessel for real-time blood pressure monitoring. The elastic cuff is made of bio-compatible soft silicone material and is filled with bio-compatible insulating silicone oil with an immersed MEMS pressure sensor. This technique avoids vessel penetration and substantially minimizes vessel restriction due to the soft cuff elasticity, thus attractive for long-term monitoring. A rigid isolation ring is used to isolate the cuff from environmental variations to suppress baseline drift in the measured waveform inside the monitoring cuff. The prototype monitoring cuff is. p wrapped around the right carotid artery of a laboratory rat to measure real-time blood pressure waveform. The measured in vivo blood waveform is compared with a reference waveform recorded simultaneously by using a commercial catheter-tip transducer inserted into the left carotid artery, showing matched waveforms with a scaling factor about 0.03 and a baseline drift of 0.6 mm, Hg. The measured baseline drift is three times smaller compared to using a cuff without a rigid isolation ring.
引用
收藏
页码:2863 / +
页数:2
相关论文
共 50 条
  • [21] Integrated implantable device for long-term glucose monitoring
    Dept. of Chem./Nuclear Engineering, University of New Mexico, Albuquerque, NM 87131-1341, United States
    BIOSENS. BIOELECTRON., 5 (485-494):
  • [22] INTEGRATED IMPLANTABLE DEVICE FOR LONG-TERM GLUCOSE MONITORING
    WILKINS, E
    ATANASOV, P
    MUGGENBURG, BA
    BIOSENSORS & BIOELECTRONICS, 1995, 10 (05): : 485 - 494
  • [23] AMBULATORY LONG-TERM BLOOD-PRESSURE MONITORING - WHAT IS NORMAL
    BAUMGART, P
    ZEITSCHRIFT FUR KARDIOLOGIE, 1991, 80 : 29 - 32
  • [24] Long-term Blood Pressure Monitoring (ABDM): 24 Hours or longer?
    Kommer, W.
    JOURNAL FUR HYPERTONIE, 2011, 15 (01): : 36 - 36
  • [25] DATA-ANALYSIS OF LONG-TERM BLOOD-PRESSURE MONITORING
    MERIER, GR
    ABETEL, G
    BOUSQUET, JC
    CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1985, 7 (2-3) : 381 - 385
  • [26] IMPLANTABLE TELEMETRY SYSTEM FOR LONG-TERM EMG
    MARQUES, M
    DUTOURNE, B
    BIOTELEMETRY, 1977, 4 (01) : 28 - 33
  • [27] Validation of a telemetry system for long-term measurement of blood pressure
    Brooks, D
    Horner, RL
    Kozar, LF
    Waddell, TK
    Render, CL
    Phillipson, EA
    JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (02) : 1012 - 1018
  • [28] The sympathetic nervous system and long-term blood pressure regulation
    Lohmeier, TE
    AMERICAN JOURNAL OF HYPERTENSION, 2001, 14 (06) : 147S - 154S
  • [29] Baseline Blood Pressure, the 2017 ACC/AHA High Blood Pressure Guidelines, and Long-Term Cardiovascular Risk in SPRINT
    Vaduganathan, Muthiah
    Pareek, Manan
    Qamar, Arman
    Pandey, Ambarish
    Olsen, Michael H.
    Bhatt, Ddeepak L.
    AMERICAN JOURNAL OF MEDICINE, 2018, 131 (08): : 956 - 960
  • [30] A novel strategy for long-term implantable artificial pancreas
    Ricotti, Leonardo
    Assaf, Tareq
    Menciassi, Arianna
    Dario, Paolo
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2849 - 2853