Biomechanical Analysis of the Use of Stems in Revision Total Knee Arthroplasty

被引:11
|
作者
Innocenti, Bernardo [1 ]
Bori, Edoardo [1 ]
Pianigiani, Silvia [1 ]
机构
[1] Univ Libre Bruxelles, BEAMS Dept, Av F Roosevelt,50 CP165-56, B-1050 Brussels, Belgium
来源
BIOENGINEERING-BASEL | 2022年 / 9卷 / 06期
关键词
revision TKA; stem; biomechanics; micromotions; bone stress; risk of fracture;
D O I
10.3390/bioengineering9060259
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Adequate fixation is fundamental in revision total knee arthroplasty; consequently, surgeons must determine the correct set-up for each patient, choosing from numerous stem solutions. Several designs are currently available on the market, but there are no evidence-based quantitative biomechanical guideline yet. Therefore, several stems were designed and analyzed using a previously-validated finite-element model. The following parameters were studied: stem design characteristics (length and shape), added features (straight/bowed stem), fixation technique, and effect of slots/flutes. Bone stress and Risk of Fracture (RF) were analyzed in different regions of interest during a squat (up to 120 degrees). For the femoral stem, the results indicated that all parameters influenced the bone stress distribution. The maximum von Mises stress and RF were always located near the tip of the stem. The long stems generated stress-shielding in the distal bone. Regarding the tibial stem, cemented stems showed lower micromotions at the bone-tibial tray interface and at the stem tip compared to press-fit stems, reducing the risk of implant loosening. The results demonstrated that anatomical shapes and slots reduce bone stress and risk of fracture, whereas flutes have the opposite effect; no relevant differences were found in this regard when alternating cemented and press-fit stem configurations. Cemented tibial stems reduce antero-posterior micromotions, preventing implant loosening.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] The use of proximal fixed modular stems in revision of total hip arthroplasty
    Higuera, Carlos A.
    Hanna, George
    Florjancik, Karen
    Allan, D. Gordon
    Robinson, Raymond
    Barsoum, Wael K.
    JOURNAL OF ARTHROPLASTY, 2006, 21 (04): : 112 - 116
  • [32] Revision total knee arthroplasty
    Luria, S
    Kandel, L
    Segal, D
    Liebergall, M
    Mattan, Y
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2003, 5 (08): : 552 - 555
  • [33] Revision total knee arthroplasty
    Hoeffel, DP
    Rubash, HE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (380) : 116 - 132
  • [34] REVISION OF TOTAL KNEE ARTHROPLASTY
    INSALL, JN
    DETHMERS, DA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1982, (170) : 123 - 130
  • [35] REVISION TOTAL KNEE ARTHROPLASTY
    LENZ, H
    WIENER KLINISCHE WOCHENSCHRIFT, 1994, 106 (12) : 387 - 389
  • [36] Revision Total Knee Arthroplasty with Use of a Constrained Condylar Knee Prosthesis
    Kim, Young-Hoo
    Kim, Jun-Shik
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (06): : 1440 - 1447
  • [37] Modular revision stems in total hip arthroplasty
    Jones, RE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (420) : 142 - 147
  • [38] Biomechanical Effects of Tibial Stems with Different Structures on Human Knee Joint after Total Knee Arthroplasty: A Finite Element Analysis
    Meng Zhang
    Kaiwen Zhang
    He Gong
    Journal of Bionic Engineering, 2022, 19 : 197 - 208
  • [39] Biomechanical Effects of Tibial Stems with Different Structures on Human Knee Joint after Total Knee Arthroplasty: A Finite Element Analysis
    Zhang, Meng
    Zhang, Kaiwen
    Gong, He
    JOURNAL OF BIONIC ENGINEERING, 2022, 19 (01): : 197 - 208
  • [40] Revision of Unconstrained Total Knee Arthroplasty - A Technical Analysis
    Haasper, C.
    Kendoff, D.
    Gebauer, M.
    Gehrke, T.
    Klauser, W.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2012, 150 (03): : 290 - 295