A novel urinary oxalate determination method via a catalase model compound with oxalate oxidase

被引:15
|
作者
Zuo, Guanke [2 ]
Jiang, Xiaojun [2 ]
Liu, Hui [2 ]
Zhang, Jingyan [1 ,2 ]
机构
[1] E China Univ Sci & Technol, State Key Lab Bioreactor Engn, Shanghai 200237, Peoples R China
[2] E China Univ Sci & Technol, Sch Pharm, Dept Pharmaceut Sci, Shanghai 200237, Peoples R China
基金
美国国家科学基金会;
关键词
OXALIC-ACID; ENZYME; IMMOBILIZATION; BIOSENSOR; ASSAY; CARBOXYLATE; COMPLEXES; ASCORBATE; SYSTEM;
D O I
10.1039/b9ay00247b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work describes a novel method of urinary oxalate determination based on a catalase model compound MnL(H2O)(2)(ClO4)(2) (L = bis(2-pyridylmethyl)ammo)propionic acid) Urinary oxalate is first decomposed by the oxalate oxidase into carbon dioxide and hydrogen peroxide. The later is then disproportionated into water and oxygen by the catalase model compound forming a color compound, which can be spectrophotometrically monitored The oxalate concentration of the sample is quantified according to the UV-vis absorbance of the formed color compound This model compound method maintains the specificity and sensitivity of the conventional enzymatic assay It has several advantages over the traditional enzymatic method, including low cost, simplicity, large linear range, and adjustable assay time The model compound method showed a very good linearity in the range of 0 002-20 mmol L-1 oxalate, with a detection limit of 2 mu mol L-1 oxalate The mean urinary oxalate determined by this method was 28.6 mu g mL (1), standard deviation (SD) was 1 07 mu g mL(-1), and variation coefficient (CV) is less than 4% The results are consistent with that acquired from the enzymatic and HPLC methods The model compound method also showed that the model compounds of the corresponding enzymes can be an alternative to the enzymes, thus the cost of the methods or assays using the enzymes can be greatly decreased
引用
收藏
页码:254 / 258
页数:5
相关论文
共 50 条
  • [41] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF OXALATE WITH IMMOBILIZED OXALATE OXIDASE
    ALMUAIBED, AM
    TOWNSHEND, A
    ANALYTICA CHIMICA ACTA, 1989, 218 (01) : 1 - 6
  • [42] MODIFIED METHOD FOR URINARY OXALATE
    HUSDAN, H
    LEUNG, M
    OREOPOULOS, D
    RAPOPORT, A
    CLINICAL CHEMISTRY, 1976, 22 (09) : 1538 - 1538
  • [43] Determination of urinary oxalate using oxalate-selective membrane electrodes
    Stefan, RI
    Draghici, I
    Baiulescu, GE
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 65 (1-3) : 250 - 252
  • [44] Determination of urinary oxalate using oxalate-selective membrane electrodes
    Stefan, RI
    Draghici, I
    Baiulescu, GE
    TECHNICAL DIGEST OF THE SEVENTH INTERNATIONAL MEETING ON CHEMICAL SENSORS, 1998, : 807 - 809
  • [45] DIRECT DETERMINATION OF URINARY OXALATE BY A CONTINUOUS-FLOW METHOD
    GOLDSACK, K
    GINMAN, RFA
    WRIGHT, JM
    MEDICAL LABORATORY SCIENCES, 1990, 47 (02): : 73 - 79
  • [46] ENZYME ELECTRODE BASED ON OXALATE OXIDASE IMMOBILIZED IN GELATIN FOR SPECIFIC DETERMINATION OF OXALATE
    DINCKAYA, E
    TELEFONCU, A
    INDIAN JOURNAL OF BIOCHEMISTRY & BIOPHYSICS, 1993, 30 (05): : 282 - 284
  • [47] ANALYTICAL ISOTACHOPHORESIS - A RAPID AND SENSITIVE METHOD FOR DETERMINATION OF URINARY OXALATE
    SCHMIDT, K
    HAGMAIER, V
    BRUCHELT, G
    RUTISHAUSER, G
    UROLOGICAL RESEARCH, 1980, 8 (03): : 177 - 180
  • [48] DETERMINATION OF URINARY OXALATE BY ION CHROMATOGRAPHY
    SINGH, RP
    NANCOLLAS, GH
    ANALYTICAL LETTERS, 1986, 19 (13-14) : 1487 - 1499
  • [49] Rapid and convenient determination of oxalic acid employing a novel oxalate biosensor based on oxalate oxidase and SIRE technology
    Hong, F
    Nilvebrant, NO
    Jönsson, LJ
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (09): : 1173 - 1181
  • [50] RADIOENZYMATIC PROCEDURE FOR URINARY OXALATE DETERMINATION
    BENNETT, DJ
    COLE, FE
    FROHLICH, ED
    ERWIN, DT
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1978, 91 (05): : 822 - 830