Enhancements to commissioning techniques and quality assurance of brachytherapy treatment planning systems that use model-based dose calculation algorithms

被引:54
|
作者
Rivard, Mark J. [1 ]
Beaulieu, Luc [4 ,5 ,6 ]
Mourtada, Firas [2 ,3 ]
机构
[1] Tufts Univ, Sch Med, Dept Radiat Oncol, Boston, MA 02111 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Expt Diagnost Imaging, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[4] Univ Laval, CHU Quebec, Dept Radiooncol, Quebec City, PQ G1R 2J6, Canada
[5] Univ Laval, CHU Quebec, Ctr Rech Cancerol, Quebec City, PQ G1R 2J6, Canada
[6] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ G1R 2J6, Canada
关键词
brachytherapy; dose calculation algorithm; treatment planning system; QA; SHIELDED CERVICAL APPLICATORS; RATE ENDORECTAL BRACHYTHERAPY; PERMANENT PROSTATE IMPLANTS; FINITE PATIENT DIMENSIONS; EYE PLAQUE BRACHYTHERAPY; MONTE-CARLO CALCULATIONS; RADIATION-THERAPY; INTRACAVITARY BRACHYTHERAPY; INTERSTITIAL BRACHYTHERAPY; BREAST BRACHYTHERAPY;
D O I
10.1118/1.3429131
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The current standard for brachytherapy dose calculations is based on the AAPM TG-43 formalism. Simplifications used in the TG-43 formalism have been challenged by many publications over the past decade. With the continuous increase in computing power, approaches based on fundamental physics processes or physics models such as the linear-Boltzmann transport equation are now applicable in a clinical setting. Thus, model-based dose calculation algorithms (MBDCAs) have been introduced to address TG-43 limitations for brachytherapy. The MBDCA approach results in a paradigm shift, which will require a concerted effort to integrate them properly into the radiation therapy community. MBDCA will improve treatment planning relative to the implementation of the traditional TG-43 formalism by accounting for individualized, patient-specific radiation scatter conditions, and the radiological effect of material heterogeneities differing from water. A snapshot of the current status of MBDCA and AAPM Task Group reports related to the subject of QA recommendations for brachytherapy treatment planning is presented. Some simplified Monte Carlo simulation results are also presented to delineate the effects MBDCA are called to account for and facilitate the discussion on suggestions for (i) new QA standards to augment current societal recommendations, (ii) consideration of dose specification such as dose to medium in medium, collisional kerma to medium in medium, or collisional kerma to water in medium, and (iii) infrastructure needed to uniformly introduce these new algorithms. Suggestions in this Vision 20/20 article may serve as a basis for developing future standards to be recommended by professional societies such as the AAPM, ESTRO, and ABS toward providing consistent clinical implementation throughout the brachytherapy community and rigorous quality management of MBDCA-based treatment planning systems. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3429131]
引用
收藏
页码:2645 / 2658
页数:14
相关论文
共 50 条
  • [31] Validation of a Commercial Model-Based Collapsed Cone Dose Algorithm for High Dose-Rate Gynecological Brachytherapy Treatment Planning
    Price, M. J.
    Fontenot, J. D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [32] Guidance for Early Adoption of Model-Based Dose Calculation Algorithms in Brachytherapy: Progress Report from AAPM Task Group 186
    Beaulieu, L.
    Tedgren, A. Carlsson
    Carrier, J.
    Davis, S.
    Mourtada, F.
    Rivard, M.
    Thomson, R.
    Verhaegen, F.
    Wareing, T.
    Williamson, J.
    MEDICAL PHYSICS, 2011, 38 (06) : 3651 - +
  • [33] Model-based software quality assurance tools and techniques presented at FASE 2018
    Russo, Alessandra
    Schuerr, Andy
    INTERNATIONAL JOURNAL ON SOFTWARE TOOLS FOR TECHNOLOGY TRANSFER, 2020, 22 (01) : 1 - 2
  • [34] Model-based Water Quality Assurance in Ground and Surface Provisioning Systems
    Gentile, Ugo
    Nardone, Roberto
    Mazzocca, Nicola
    De Paola, Francesco
    Giugni, Maurizio
    Marrone, Stefano
    2015 10TH INTERNATIONAL CONFERENCE ON P2P, PARALLEL, GRID, CLOUD AND INTERNET COMPUTING (3PGCIC), 2015, : 527 - 532
  • [35] Model-based software quality assurance tools and techniques presented at FASE 2018
    Alessandra Russo
    Andy Schürr
    International Journal on Software Tools for Technology Transfer, 2020, 22 : 1 - 2
  • [36] Compass model-based quality assurance for stereotactic VMAT treatment plans
    Valve, Assi
    Keyrilainen, Jani
    Kulmala, Jarmo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 : 42 - 50
  • [37] Knowledge Based Planning for Lung SBRT: Model Transferability between Treatment Systems and Calculation Algorithms
    Kim, H.
    Mccaw, T. J.
    Pawlowski, J.
    Huq, S.
    Wilhite, T. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E679 - E679
  • [38] CHALLENGES AND REQUIREMENTS FOR THE INTRODUCTION OF MODEL-BASED DOSE CALCULATION ALGORITHMS IN BRACHYTHERAPY: A STATUS UPDATE FROM AAPM TASK-GROUP 186
    Beaulieu, L.
    Tedgren, Carlsson
    Carrier, J. F.
    Davis, S.
    Mourtada, F.
    Rivard, M.
    Thomson, R.
    Verhaegen, F.
    Wareing, T.
    Williamson, J.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S58 - S58
  • [39] On an Exemplar Supporting Model-based Quality Assurance Research for Healthcare Systems-of-Systems
    Sakizloglou, Lucas
    Khakharova, Taisiya
    Ruehs, Florian
    Lambers, Leen
    PROCEEDINGS OF THE 2024 IEEE/ACM 12TH INTERNATIONAL WORKSHOP ON SOFTWARE ENGINEERING FOR SYSTEMS-OF-SYSTEMS AND SOFTWARE ECOSYSTEMS, SESOS 2024, 2024, : 57 - 60
  • [40] Commissioning a superposition dose calculation model for 6 MV photon beams on a radiotherapy treatment planning system
    Ambolt, P.
    Bowden, J.
    Cooper, M.
    Henry, A.
    McCormack, S.
    Morgan, A.
    Patrick, S.
    Thompson, R.
    Thwaites, D.
    CLINICAL ONCOLOGY, 2007, 19 (03) : S40 - S40