The Accuracy of Wrist Skin Temperature in Detecting Ovulation Compared to Basal Body Temperature: Prospective Comparative Diagnostic Accuracy Study

被引:31
|
作者
Zhu, Tracy Y. [1 ]
Rothenbuhler, Martina [2 ]
Hamvas, Gyorgyi [1 ]
Hofmann, Anja [1 ]
Welter, JoEllen [1 ]
Kahr, Maike [1 ]
Kimmich, Nina [3 ]
Shilaih, Mohaned [2 ]
Leeners, Brigitte [1 ,4 ]
机构
[1] Univ Hosp Zurich, Dept Reprod Endocrinol, Ramistr 100, CH-8091 Zurich, Switzerland
[2] Ava AG, Zurich, Switzerland
[3] Univ Hosp Zurich, Dept Obstet, Zurich, Switzerland
[4] Univ Zurich, Zurich, Switzerland
关键词
ovulation; basal body temperature; BBT; oral temperature; wrist skin temperature; diagnostic accuracy; thermometer; fertility; menstruation; wearable; sensor; mobile phone; CIRCADIAN-RHYTHM; PREDICTION; INDEX;
D O I
10.2196/20710
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: As a daily point measurement, basal body temperature (BBT) might not be able to capture the temperature shift in the menstrual cycle because a single temperature measurement is present on the sliding scale of the circadian rhythm. Wrist skin temperature measured continuously during sleep has the potential to overcome this limitation. Objective: This study compares the diagnostic accuracy of these two temperatures for detecting ovulation and to investigate the correlation and agreement between these two temperatures in describing thermal changes in menstrual cycles. Methods: This prospective study included 193 cycles (170 ovulatory and 23 anovulatory) collected from 57 healthy women. Participants wore a wearable device (Ava Fertility Tracker bracelet 2.0) that continuously measured the wrist skin temperature during sleep. Daily BBT was measured orally and immediately upon waking up using a computerized fertility tracker with a digital thermometer (Lady-Comp). An at-home luteinizing hormone test was used as the reference standard for ovulation. The diagnostic accuracy of using at least one temperature shift detected by the two temperatures in detecting ovulation was evaluated. For ovulatory cycles, repeated measures correlation was used to examine the correlation between the two temperatures, and mixed effect models were used to determine the agreement between the two temperature curves at different menstrual phases. Results: Wrist skin temperature was more sensitive than BBT (sensitivity 0.62 vs 0.23; P<.001) and had a higher true-positive rate (54.9% vs 20.2%) for detecting ovulation; however, it also had a higher false-positive rate (8.8% vs 3.6%), resulting in lower specificity (0.26 vs 0.70; P=.002). The probability that ovulation occurred when at least one temperature shift was detected was 86.2% for wrist skin temperature and 84.8% for BBT. Both temperatures had low negative predictive values (8.8% for wrist skin temperature and 10.9% for BBT). Significant positive correlation between the two temperatures was only found in the follicular phase (rmcorr correlation coefficient=0.294; P=.001). Both temperatures increased during the postovulatory phase with a greater increase in the wrist skin temperature (range of increase: 0.50 degrees C vs 0.20 degrees C). During the menstrual phase, the wrist skin temperature exhibited a greater and more rapid decrease (from 36.13 degrees C to 35.80 degrees C) than BBT (from 36.31 degrees C to 36.27 degrees C). During the preovulatory phase, there were minimal changes in both temperatures and small variations in the estimated daily difference between the two temperatures, indicating an agreement between the two curves. Conclusions: For women interested in maximizing the chances of pregnancy, wrist skin temperature continuously measured during sleep is more sensitive than BBT for detecting ovulation. The difference in the diagnostic accuracy of these methods was likely attributed to the greater temperature increase in the postovulatory phase and greater temperature decrease during the menstrual phase for the wrist skin temperatures.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] ACCURACY OF BASAL BODY-TEMPERATURE FOR OVULATION DETECTION
    MOGHISSI, KS
    FERTILITY AND STERILITY, 1976, 27 (02) : 207 - 208
  • [2] ACCURACY OF BASAL BODY-TEMPERATURE FOR OVULATION DETECTION
    MOGHISSI, KS
    FERTILITY AND STERILITY, 1976, 27 (12) : 1415 - 1421
  • [3] A COMPARISON OF THE ACCURACY OF BASAL BODY-TEMPERATURE AND THE INSLER SCORE OF CERVICAL CHANGES IN PREDICTING THE DAY OF OVULATION
    LEADER, A
    WISEMAN, D
    TAYLOR, PJ
    FERTILITY AND STERILITY, 1984, 42 (01) : 163 - 163
  • [4] Diagnostic accuracy of routine postoperative body temperature measurements
    Vermeulen, H
    Storm-Versloot, MN
    Goossens, A
    Speelman, P
    Legemate, DA
    CLINICAL INFECTIOUS DISEASES, 2005, 40 (10) : 1404 - 1410
  • [5] A THERMOGRAPHIC STUDY OF THE EFFECT OF BODY-COMPOSITION AND AMBIENT-TEMPERATURE ON THE ACCURACY OF MEAN SKIN TEMPERATURE CALCULATIONS
    LIVINGSTONE, SD
    NOLAN, RW
    FRIM, J
    REED, LD
    LIMMER, RE
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1987, 56 (01): : 120 - 125
  • [6] ACCURACY OF ENDOMETRIAL DATING - CORRELATION OF ENDOMETRIAL DATING WITH BASAL BODY TEMPERATURE AND MENSES
    NOYES, RW
    HAMAN, JO
    FERTILITY AND STERILITY, 1953, 4 (06) : 504 - 517
  • [7] The Effectiveness of Cervical Mucus Electrical Impedance Compared to Basal Body Temperature to Determine Ovulation Window
    Tabaa, Suzanne
    Katie, Sikes J.
    Levy, Gary
    Rydfors, Jan
    Hambright, Sealy
    REPRODUCTIVE SCIENCES, 2023, 30 : 110A - 110A
  • [8] Lack of Accuracy of Body Temperature for Detecting Serious Bacterial Infection in Febrile Episodes
    De, Sukanya
    Williams, Gabrielle J.
    Teixeira-Pinto, Armando
    Macaskill, Petra
    McCaskill, Mary
    Isaacs, David
    Craig, Jonathan C.
    PEDIATRIC INFECTIOUS DISEASE JOURNAL, 2015, 34 (09) : 940 - 944
  • [9] Diagnostic Accuracy of an At-Home, Rapid Self-test for Influenza: Prospective Comparative Accuracy Study
    Geyer, Rachel E.
    Kotnik, Jack Henry
    Lyon, Victoria
    Brandstetter, Elisabeth
    Suchsland, Monica Zigman
    Han, Peter D.
    Graham, Chelsey
    Ilcisin, Misja
    Kim, Ashley E.
    Chu, Helen Y.
    Nickerson, Deborah A.
    Starita, Lea M.
    Bedford, Trevor
    Lutz, Barry
    Thompson, Matthew J.
    JMIR PUBLIC HEALTH AND SURVEILLANCE, 2022, 8 (02):
  • [10] Measurement of body temperature in adult patients: Comparative study of accuracy, reliability and validity of different devices
    Rubia-Rubia, J.
    Arias, A.
    Sierra, A.
    Aguirre-Jaime, A.
    INTERNATIONAL JOURNAL OF NURSING STUDIES, 2011, 48 (07) : 872 - 880