Detection and typing of Campylobacter jejuni and Campylobacter coli and analysis of indicator organisms in three waterborne outbreaks in Finland

被引:138
|
作者
Hänninen, ML
Haajanen, H
Pummi, T
Wermundsen, K
Katila, ML
Sarkkinen, H
Miettinen, I
Rautelin, H
机构
[1] Univ Helsinki, Dept Food & Environm Hyg, FIN-00014 Helsinki, Finland
[2] Food & Environm Lab, Varkaus, Finland
[3] Lahti Res Lab, Lahti, Finland
[4] Dept Environm Hlth, Vihti, Finland
[5] Kuopio Univ Hosp, Dept Clin Microbiol, SF-70210 Kuopio, Finland
[6] Cent Hosp Paijat Hame, Dept Clin Microbiol, Lahti, Finland
[7] Natl Publ Hlth Lab, Kuopio, Finland
[8] Univ Helsinki, Dept Bacteriol & Immunol, Haartman Inst, Helsinki, Finland
[9] HUCH Lab Diagnost, Helsinki, Finland
关键词
D O I
10.1128/AEM.69.3.1391-1396.2003
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Waterborne outbreaks associated with contamination of drinking water by Campylobacter jejuni are rather common in the Nordic countries Sweden, Norway, and Finland, where in sparsely populated districts groundwater is commonly used without disinfection. Campylobacters, Escherichia coli, or other coliforms have rarely been detected in potential sources. We studied three waterborne outbreaks in Finland caused by C. jejuni and used sample volumes of 4,000 to 20,000 ml for analysis of campylobacters; and sample volumes of 1 to 5,000 ml for analysis of coliforms and E. coli, depending on the sampling site. Multiple samples obtained from possible sources (water distribution systems and environmental water sources) and the use of large sample volumes (several liters) increased the chance of detecting the pathogen C. jejuni in water. Filtration of a large volume (1,000 to 2,000 ml) also increased the rate of detection of coliforms and E. coli. To confirm the association between drinking water contamination and illness, a combination of Penner serotyping and pulsed-field gel electrophoresis (digestion with SmaI and KpnI) was found to be useful. This combination reliably verified similarity or dissimilarity of C. jejuni isolates from patient samples, from drinking water, and from other environmental sources, thus confirming the likely reservoir of an outbreak.
引用
收藏
页码:1391 / 1396
页数:6
相关论文
共 50 条
  • [41] Use of culture, PCR analysis, and DNA microarrays for detection of Campylobacter jejuni and Campylobacter coli from chicken feces
    Keramas, G
    Bang, DD
    Lund, M
    Madsen, M
    Bunkenborg, H
    Telleman, P
    Christensen, CBV
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (09) : 3985 - 3991
  • [42] Comparison of three AFLP techniques for genotyping human and foodborne strains of Campylobacter jejuni and Campylobacter coli
    Kelly, C.
    Moran, L.
    Madden, R. H.
    ZOONOSES AND PUBLIC HEALTH, 2007, 54 : 37 - 37
  • [43] Development and application of a new scheme for typing Campylobacter jejuni and Campylobacter coli by PCR-based restriction fragment length polymorphism analysis
    Shi, F
    Chen, YY
    Wassenaar, TM
    Woods, WH
    Coloe, PJ
    Fry, BN
    JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (05) : 1791 - 1797
  • [44] Prevalence of Thermotolerant Campylobacter spp. in Chicken Meat in Croatia and Multilocus Sequence Typing of a Small Subset of Campylobacter jejuni and Campylobacter coli Isolates
    Mikulic, Marina
    Humski, Andrea
    Njari, Bela
    Ostovic, Mario
    Duvnjak, Sanja
    Cvetnic, Zeljko
    FOOD TECHNOLOGY AND BIOTECHNOLOGY, 2016, 54 (04) : 475 - 481
  • [45] Typing of human Campylobacter jejuni isolates in Finland by pulsed-field gel electrophoresis
    Hänninen, ML
    Pajarre, S
    Klossner, ML
    Rautelin, H
    JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (06) : 1787 - 1789
  • [46] Evaluation of a PCR assay for the detection and identification of Campylobacter jejuni and Campylobacter coli in retail poultry products
    Mateo, E
    Cárcamo, J
    Urquijo, M
    Perales, I
    Fernández-Astorga, A
    RESEARCH IN MICROBIOLOGY, 2005, 156 (04) : 568 - 574
  • [47] Bacteriophage Receptor Binding Protein Based Assays for the Simultaneous Detection of Campylobacter jejuni and Campylobacter coli
    Javed, Muhammad A.
    Poshtiban, Somayyeh
    Arutyunov, Denis
    Evoy, Stephane
    Szymanski, Christine M.
    PLOS ONE, 2013, 8 (07):
  • [48] Detection and quantification of Campylobacter jejuni and Campylobacter coli using real-time multiplex PCR
    Toplak, N.
    Kovac, M.
    Piskernik, S.
    Mozina, S. Smole
    Jersek, B.
    JOURNAL OF APPLIED MICROBIOLOGY, 2012, 112 (04) : 752 - 764
  • [49] A sensitive gold-nanorods-based nanobiosensor for specific detection of Campylobacter jejuni and Campylobacter coli
    Saeed Shams
    Bita Bakhshi
    Tahereh Tohidi Moghadam
    Mehrdad Behmanesh
    Journal of Nanobiotechnology, 17
  • [50] A sensitive gold-nanorods-based nanobiosensor for specific detection of Campylobacter jejuni and Campylobacter coli
    Shams, Saeed
    Bakhshi, Bita
    Moghadam, Tahereh Tohidi
    Behmanesh, Mehrdad
    JOURNAL OF NANOBIOTECHNOLOGY, 2019, 17 (1)