Measurement of sound fields using Mach-Zehnder interferometer

被引:4
|
作者
Nemoto, M [1 ]
Mizutani, K
Ezure, T
Masuyama, H
机构
[1] Univ Tsukuba, Grad Sch Sci & Engn, Tsukuba, Ibaraki 3058573, Japan
[2] Univ Tsukuba, Grad Sch Syst & Informat Engn, Tsukuba, Ibaraki 3058573, Japan
[3] Univ Tsukuba, Grad Sch Engn, Tsukuba, Ibaraki 3058573, Japan
[4] Toba Natl Coll Maritime Technol, Dept Elect Mech Engn, Toba 5178501, Japan
关键词
measurement; sound fields; sound pressure; visualization; reconstruction; projection; Mach-Zehnder interferometer; acoustooptic interaction; computerized tomography; CT;
D O I
10.1143/JJAP.43.6444
中图分类号
O59 [应用物理学];
学科分类号
摘要
In this paper, we propose a method of noncontact measurement of sound fields, radiating from an ultrasonic transducer, using a Mach-Zehnder interferometer. The deviation of refractive index, which depends on sound pressure, was transformed into the intensity of the interference light using the interferometer, in which a light beam passes through the measured object. Projection data bused in the computerized tomography (CT) method along the optical axis was obtained by single linear scanning in the range of +/-40 mm and was electronically quadrature-detected as the complex amplitude. The 36 projections were acquired by the rotation of the sound fields in the range of 0 less than or equal to theta less than or equal to pi (rad) with an interval of pi/36 rad. Finally, the complex sound fields were reconstructed in the region of 48 x 48 mm(2) by the CT method. The plane of reconstruction was 5 mm apart from the plane of the transducer. The ultrasonic transducer used in the experiment was driven at a frequency of 1.416 MHz and had a diameter of 8.0 mm. The experimental results were approximately in agreement with the numerical results.
引用
收藏
页码:6444 / 6447
页数:4
相关论文
共 50 条
  • [31] Manufacturing error measurement for minute aspherical lens using Mach-Zehnder interferometer
    Oshikiri, M
    Nishioka, K
    SPECIFICATION, PRODUCTION, AND TESTING OF OPTICAL COMPONENTS AND SYSTEMS, 1996, 2775 : 35 - 42
  • [32] Measurement of In-Fiber Refractive Index Change Using a Mach-Zehnder Interferometer
    Ahmed, Farid
    Ahsani, Vahid
    Jo, Seunghwan
    Bradley, Colin
    Toyserkani, Ehsan
    Jun, Martin B. G.
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2019, 31 (01) : 74 - 77
  • [33] Measurement of birefringence using polarization phase-shifting Mach-Zehnder interferometer
    Sircar, Santa
    Bhattacharya, Kallol
    OPTICAL ENGINEERING, 2015, 54 (11)
  • [34] Measurement of refractive index and temperature using balloon shaped Mach-Zehnder interferometer
    Zhao, Lilong
    Liu, Bo
    Wu, Yongfeng
    Sun, Tingting
    Mao, Yaya
    Nan, Tong
    OPTIK, 2019, 188 : 115 - 119
  • [35] A Hybrid Mach-Zehnder Interferometer for Refractive Index and Temperature Measurement
    Ni, Xiaoqi
    Wang, Ming
    Guo, Dongmei
    Hao, Hui
    Zhu, Jiali
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2016, 28 (17) : 1850 - 1853
  • [36] Multimode Fiber Mach-Zehnder Interferometer for Measurement of Refractive Index
    Chen, Chien-Hsing
    Chen, Yi-Chun
    Wang, Jian-Neng
    Chau, Lai-Kwan
    Tang, Jaw-Luen
    Wu, Wei-Te
    2010 IEEE SENSORS, 2010, : 61 - 64
  • [37] ALIGNMENT TECHNIQUE FOR MACH-ZEHNDER INTERFEROMETER USING A LASER
    CHEN, CS
    BIRD, JD
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1971, 4 (03): : 157 - &
  • [38] Absolute strain measurement based on a microfiber Mach-Zehnder interferometer
    Kim, Sung-Jae
    Yoon, Min-Seok
    Kim, Sunduck
    Kwon, Oh-Jang
    Han, Young-Geun
    23RD INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, 2014, 9157
  • [39] In-fiber Mach-Zehnder interferometer for wearable respiration measurement
    Cao, Zhongwei
    Shao, Min
    Yuan, Yubo
    Ma, Xinyuan
    Yu, Yang
    Qiao, Xueguang
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 364
  • [40] A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement
    Feng, Zhongyao
    Li, Jiacheng
    Qiao, Xueguang
    Li, Ling
    Yang, Hangzhou
    Hu, Manli
    SENSORS, 2014, 14 (08): : 14210 - 14221