High Impedance Fault Area Location in Distribution Systems Based on Current Zero Sequence Component

被引:26
|
作者
Vianna, J. T. A. [1 ]
Araujo, L. R. [1 ]
Penido, D. R. R. [1 ]
机构
[1] Univ Fed Juiz de Fora UFJF, Juiz De Fora, MG, Brazil
关键词
Automation systems; Distribution systems; High impedance faults; Power system protection; Real Time Digital Simulator; Unbalanced operation; ALGORITHM;
D O I
10.1109/TLA.2016.7437220
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a new methodology for detection and area location of high impedance faults (HIF) on unbalanced distribution systems. The method is called Quasi-Differential Zero Sequence Protection (PQDSZ) and it detects these faults by analyzing the current zero sequence rms value on a distribution feeder. The detection relies on a differential area, defined by two points of measurement. The data is sent to a control center, which analyzes the relation between the received currents and sends an alarm if any problem is detected. A simulation system with the RTDS and real automation equipment is presented, in order to validate the PQDSZ method.
引用
收藏
页码:759 / 766
页数:8
相关论文
共 50 条
  • [1] Impedance fault location technology for a distribution network based on a zero-sequence component
    Qi Z.
    Huang Z.
    Chen Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (06): : 54 - 62
  • [2] Section Location Method for High Impedance Grounding Fault Based on Declining Periodic Component of Zero Sequence Current
    Liu, Zhiwen
    Dong, Xuzhu
    Zou, Lin
    Wu, Zhengrong
    Li, Jie
    Zeng, Dehui
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (07): : 161 - 168
  • [3] Criterion based on the fault component of zero sequence current for online fault location of single-phase fault in distribution network
    Ni, Guangkui
    Bao, Hai
    Zhang, Li
    Yang, Yihan
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (31): : 118 - 122
  • [4] A Simple High Impedance Fault Detection Method based on Phase Displacement and Zero Sequence Current for Grounded Distribution Systems
    Myint, Shwe
    Wichakool, Warit
    Santiprapan, Phonsit
    2018 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2018,
  • [5] Grounding Fault Location of Active Distribution Network Based on Zero Sequence Current Distribution
    Zhou F.
    Xiao S.
    Dianwang Jishu/Power System Technology, 2022, 46 (05): : 1820 - 1829
  • [6] Fault location of a small current grounding fault based on distribution characteristics of zero sequence voltage
    Liu J.
    Dong L.
    Xue C.
    Xue Y.
    Li J.
    Chen Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (03): : 59 - 67
  • [7] Research on High-impedance Fault Location Based on Complex Sequence Current
    Xue, Shuangzhong
    Cheng, Xingong
    Zong, Xiju
    Lv, Yongxi
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 3816 - 3820
  • [9] Detection of High Impedance Grounding Fault in Distribution Network Based on Interval Slope Curves of Zero-sequence Current
    Wei M.
    Shi F.
    Zhang H.
    Xu B.
    Wang P.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (14): : 164 - 171
  • [10] Distribution network fault location based on the zero sequence current and magnetic field detection spot
    Zhang, Li
    Yang, Yihan
    Si, Dongmei
    Yang, Peng
    Qi, Chao
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2008, 32 (14): : 73 - 76