Distribution network fault location based on the zero sequence current and magnetic field detection spot

被引:0
|
作者
Zhang, Li [1 ,2 ]
Yang, Yihan [1 ]
Si, Dongmei [1 ]
Yang, Peng [1 ]
Qi, Chao [1 ]
机构
[1] North China Electric Power University, Beijing 102206, China
[2] Beijing Institute of Machinery, Beijing 100085, China
关键词
Continuous development - Fundamental frequencies - Reliable power supply - Single phase to ground faults - Small current neutral grounding system - Wireless communication network - Wireless communications - Zero sequence current;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:73 / 76
相关论文
共 50 条
  • [1] Grounding Fault Location of Active Distribution Network Based on Zero Sequence Current Distribution
    Zhou F.
    Xiao S.
    Dianwang Jishu/Power System Technology, 2022, 46 (05): : 1820 - 1829
  • [2] Criterion based on the fault component of zero sequence current for online fault location of single-phase fault in distribution network
    Ni, Guangkui
    Bao, Hai
    Zhang, Li
    Yang, Yihan
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (31): : 118 - 122
  • [3] Fault location of a small current grounding fault based on distribution characteristics of zero sequence voltage
    Liu J.
    Dong L.
    Xue C.
    Xue Y.
    Li J.
    Chen Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (03): : 59 - 67
  • [4] Fault section location method for a distribution network based on concave and convex characteristics of transient zero sequence current
    Li W.
    Xu W.
    Qiao Z.
    Wang X.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (10): : 164 - 173
  • [5] Impedance fault location technology for a distribution network based on a zero-sequence component
    Qi Z.
    Huang Z.
    Chen Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (06): : 54 - 62
  • [6] Fault section location method for grounding fault of distribution network based on zero-sequence characteristic
    Zhu G.
    Li S.
    Lan J.
    Zeng D.
    Liu Y.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2021, 41 (01): : 34 - 40and68
  • [7] High Impedance Fault Area Location in Distribution Systems Based on Current Zero Sequence Component
    Vianna, J. T. A.
    Araujo, L. R.
    Penido, D. R. R.
    IEEE LATIN AMERICA TRANSACTIONS, 2016, 14 (02) : 759 - 766
  • [8] Detection of High Impedance Grounding Fault in Distribution Network Based on Interval Slope Curves of Zero-sequence Current
    Wei M.
    Shi F.
    Zhang H.
    Xu B.
    Wang P.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (14): : 164 - 171
  • [9] Fault location of low resistance grounding distribution network based on joint search of zero sequence voltage variation
    Liang R.
    Zhang P.
    Kong L.-C.
    Cheng M.-H.
    Wang C.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2023, 27 (01): : 139 - 147
  • [10] Fault location based on fault current amplitude comparison for active distribution network
    Gao, Mengyou
    Xu, Bingyin
    Zhang, Xinhui
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2015, 35 (07): : 21 - 25