Objectives: To describe the surgical handling, potential complications, and remodeling of an injectable, osteoconductive calcium phosphate cement (Norian SRS) for joint depression-type calcaneal fractures in humans, and to illustrate the clinical efficacy of this cement with special reference to early postoperative full weight bearing. Design: Prospective cohort study. Setting: Level I trauma centers in Bochum and Leipzig, Germany. Intervention: Thirty-six joint depression type calcaneal fractures in thirty-two patients were augmented with the calcium phosphate cement after standard open reduction with internal fixation. Postoperative full weight bearing was allowed progressively earlier, and as the study progressed, the last patients were bearing full weight as early as three weeks postoperatively. Biopsies for histologic analysis were performed at time of hardware removal after one year (seven biopsies) or in case of infection at time of debridement (five biopsies). Main outcome measures: Clinical outcome was evaluated according to a calcaneal scoring system. Data were compared and statistically analyzed between patients with postoperative full weight bearing after eight to twelve weeks and three to six weeks, respectively. Histologic findings are described. Results: Cement injection averaged ten cubic centimeters and could easily be performed under fluoroscopic control. Progressively earlier full weight-bearing was achieved without loss of reduction. There was no statistical difference in clinical outcome scores in patients with full weight bearing before or after six weeks postoperatively. The infection rate was 11 percent, possibly related to the skin incisions. The biopsies from clinically satisfactory cases showed nearly complete bone apposition, areas of vascular penetration, and reversal lines illustrating progressive cycles of resorption and new bone formation. Biopsy specimens from infected cases showed bone and cement surrounded by either fibrous tissue or acute inflammation without extensive bone apposition, Conclusions: Calcium phosphate cement augmentation of standard open reduction with internal fixation in joint-depression type calcaneal fractures allows postoperative full weight bearing as early as three weeks postoperatively. The injectable bone cement can easily be handled surgically under fluoroscopic control and has proved to be remodelable.
引用
收藏
页码:309 / 317
页数:9
相关论文
共 50 条
  • [31] Open Reduction Assisted With an External Fixator and Internal Fixation With Calcaneal Locking Plate for Intra-articular Calcaneal Fractures
    Yao, Hui
    Lu, Huading
    Zhao, Huiqing
    Lv, Lulu
    Hou, Gang
    FOOT & ANKLE INTERNATIONAL, 2017, 38 (10) : 1107 - 1114
  • [32] OPEN REDUCTION AND CIRCULAR EXTERNAL FIXATION OF INTRAARTICULAR CALCANEAL FRACTURES
    PALEY, D
    FISCHGRUND, J
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1993, (290) : 125 - 131
  • [33] Percutaneous Reduction and Fixation with Kirschner Wires versus Open Reduction Internal Fixation for the Management of Calcaneal Fractures: A Meta-Analysis
    Jianbin Wu
    Feiya Zhou
    Lei Yang
    Jun Tan
    Scientific Reports, 6
  • [34] FRACTURES - OPEN REDUCTION VS SKELETAL FIXATION
    BOURGOYNE, JR
    AMERICAN JOURNAL OF ORTHODONTICS AND ORAL SURGERY-ORAL SURGERY, 1945, 31 (08): : 519 - 532
  • [35] Conversion of external fixation to open reduction and internal fixation for complex distal radius fractures
    Natoli, R. M.
    Baer, M. R.
    Bednar, M. S.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (03) : 339 - 343
  • [36] Open Reduction and Internal Fixation of Displaced Intra-articular Calcaneal Fractures with Norian Skeletal Repair System (SRS) Bone Cement: Surgical Technique, Clinical and Radiographical Results
    Yeo, Quan You
    Kwek, Ernest B. K.
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2014, 43 (10) : 515 - 516
  • [37] Strength of internal fixation for calcaneal fractures
    Wang, CL
    Chang, GL
    Tseng, WC
    Yu, CY
    Lin, RM
    CLINICAL BIOMECHANICS, 1998, 13 (03) : 230 - 233
  • [38] The use of calcaneal anatomic plate in arthroscopically-assisted open reduction and internal fixation of intra-articular calcaneal fractures
    Wang Hong
    Zhang Qingsong
    Duan Deyu
    Yan Lijun
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2006, 26 (3): : 319 - 321
  • [39] Open reduction and internal fixation of pilon fractures
    Borrelli, J
    Catalano, L
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (08) : 573 - 582
  • [40] Open reduction and internal fixation of acetabular fractures
    G. Fica
    M. Cordova
    L. Guzman
    D. Schweitzer
    International Orthopaedics, 1998, 22 : 348 - 351