SEISMIC PERFORMANCE AND RETROFIT EVALUATION OF HOLLOW-CORE COMPOSITE BRIDGE COLUMNS

被引:0
|
作者
Abdulazeez, Mohanad M. [1 ]
Gheni, Ahmed [1 ]
Colbert, Nicholas [1 ]
ElGawady, Mohamed A. [1 ]
机构
[1] Missouri Univ Sci & Technol, Dept Civil Architectural & Environm Engn, Rolla, MO 65401 USA
关键词
TUBULAR COLUMNS; BEHAVIOR;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the seismic behavior of large-scale hollow- core fiber-reinforced polymer-concrete-steel (HC-FCS) bridge column. The HC-FCS column consists of a concrete wall sandwiched between an outer fiber-reinforced polymer (FRP) tube and an inner thin-walled steel tube. The width-to-diameter ratio for the steel tube was 147. The column had an outer diameter of 24 inches and a height-to-diameter ratio of 4.0. The steel tube was embedded into reinforced concrete footing with an embedded length of 1.25 times the steel tube diameter, while the FRP tube only confined the concrete wall thickness and curtail at the top of the footing level. The column was first tested as a vertical cantilever by applying cyclic horizontal and constant axial loads to the top of the column. Then, the column was repaired using a rapid repair technique within 6 hours duration and retested under the same seismic loading condition. The retrofitting technique includes wrapping three glass FRP layers around the outer bottommost FRP tube that ruptured at the interface joint between the column and the footing during the first test. The results revealed that the HC-FCS column achieved the ductile behavior with good inelastic deformation capacity under seismic loads. While, repaired column performed relatively well under cyclic loading, recovering 34% flexural strength and 80% of the lateral displacement capacity compared to the virgin tested column.
引用
收藏
页码:437 / 444
页数:8
相关论文
共 50 条
  • [41] Seismic retrofit of spread footings supporting bridge columns with short dowels
    Saiidi, MS
    Sanders, D
    Acharya, S
    CONSTRUCTION AND BUILDING MATERIALS, 2001, 15 (04) : 177 - 185
  • [42] Seismic Performance of Hollow Bridge Pier Columns under Multi-Directional Loading
    Liu, Xuejian
    Burgueno, Rigoberto
    Hines, Eric M.
    ACI STRUCTURAL JOURNAL, 2021, 118 (05) : 101 - 113
  • [43] Seismic performance of precast hollow concrete bridge double columns with shallow socket connection
    Zou, S.
    Zhang, C. B.
    Wenliuhan, H. S.
    Yang, Z. Y.
    Liu, Y. H.
    Zhai, Z. P.
    Feng, H.
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2023, 171
  • [44] Experimental test and modeling of hollow-core composite insulators
    Roh, Hwasung
    Oliveto, Nicholas D.
    Reinhorn, Andrei M.
    NONLINEAR DYNAMICS, 2012, 69 (04) : 1651 - 1663
  • [45] Experimental test and modeling of hollow-core composite insulators
    Hwasung Roh
    Nicholas D. Oliveto
    Andrei M. Reinhorn
    Nonlinear Dynamics, 2012, 69 : 1651 - 1663
  • [46] FRP seismic retrofit of RC square hollow section bridge piers
    Pavese, A
    Bolognini, D
    Peloso, S
    JOURNAL OF EARTHQUAKE ENGINEERING, 2004, 8 : 225 - 250
  • [47] Experimental Evaluation of the Seismic Performance of Circular Reinforced Concrete Bridge Columns
    Zheng, Gang
    Li, Guiqian
    INTELLIGENT STRUCTURE AND VIBRATION CONTROL, PTS 1 AND 2, 2011, 50-51 : 547 - 553
  • [48] Modified Steel-Jacketed Columns for Combined Blast and Seismic Retrofit of Existing Bridge Columns
    Fouche, Pierre
    Bruneau, Michel
    Chiarito, Vincent P.
    JOURNAL OF BRIDGE ENGINEERING, 2016, 21 (07)
  • [49] Seismic performance of reinforced concrete bridge columns encased in fiber composite tube
    Zhu, Z.
    Mirmiran, A.
    Saiidi, M.
    Proc. Int. Conf. Bridge Maint., Saf. Manage. - Bridge Maint., Saf., Manage., Life-Cycle Perform. Cost, 1600, (621-622):
  • [50] Use of composite materials in repairing rectangular bridge columns for improved seismic performance
    Yang, XB
    Chen, G
    Yuan, WC
    Fan, LH
    STRUCTURAL ENGINEERING AND MECHANICS, VOLS 1 AND 2, 1999, : 1273 - 1278