Behavior of Box Concrete-Filled Steel Tube Columns Considering Confinement Effect

被引:1
|
作者
Ali, Ammar Abbas [1 ]
Abbas, Nazar Jabbar [2 ]
机构
[1] Univ Technol Baghdad, Civil Engn Dept, Baghdad, Iraq
[2] Univ Technol Baghdad, Dept Construct & Projects, Baghdad, Iraq
关键词
CFST; Axial capacity; Confinement; FEA; Box section; AXIAL LOAD BEHAVIOR; STUB COLUMNS; NONLINEAR-ANALYSIS; TUBULAR COLUMNS; STRENGTH; DUCTILITY; DESIGN; MODEL;
D O I
10.1007/s13296-021-00483-0
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years considerable attention has been given to estimating the strength of box concrete-filled steel tube (CFST) stub columns. The effect of confining pressures is one of the complexities in determining the ultimate strength of the CFST columns. An experimental database of 188 tested columns has been used to produce two types of formulae: modified and simplified, that can help to predict the ultimate strength of box CFST columns with a wide range of geometrical and material properties. Different code procedures and previous formulae given by other authors were used for verification purposes and to show reliability. The axial load-shortening behaviors of composite columns were plotted using a proposed model of confined concrete adopted in a finite element analysis and compared with the experimental results. It has been found that the present formulae and concrete model have given results that agree quite well with the results of the experimental tests.
引用
收藏
页码:950 / 968
页数:19
相关论文
共 50 条
  • [21] Behavior of multicell concrete-filled steel tube columns under eccentric loading
    Yin, Fei
    Cao, Wan-Lin
    Xue, Su-Duo
    Dong, Hong-Ying
    Wang, Ru-wei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 172 (172)
  • [22] Behavior of centrally loaded concrete-filled steel-tube short columns
    Sakino, K
    Nakahara, H
    Morino, S
    Nishiyama, A
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2004, 130 (02): : 180 - 188
  • [23] The hysteretic behavior of recycled aggregate concrete-filled square steel tube columns
    Zhang, Xianggang
    Gao, Xiang
    ENGINEERING STRUCTURES, 2019, 198
  • [24] A study on the behavior of eccentrically compressed square concrete-filled steel tube columns
    Lu, F. W.
    Li, S. P.
    Sun, Guojun
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (07) : 941 - 948
  • [25] Research on the Bond Behavior of Preplaced Aggregate Concrete-Filled Steel Tube Columns
    Lv, Jing
    Zhou, Tianhua
    Du, Qiang
    Li, Kunlun
    Jin, Liangwei
    MATERIALS, 2020, 13 (02)
  • [26] Axial compressive behavior of rubberized concrete-filled steel tube short columns
    Shen, Maoyu
    Huang, Wei
    Liu, Jili
    Zhou, Zhi
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2022, 16
  • [27] Behavior of concrete-filled double skin steel tube beam-columns
    Hassan, Maha M.
    Mahmoud, Ahmed A.
    Serror, Mohammed H.
    STEEL AND COMPOSITE STRUCTURES, 2016, 22 (05): : 1141 - 1162
  • [28] Compressive behavior of concrete-filled square stainless steel tube stub columns
    Dai, Peng
    Yang, Lu
    Wang, Jie
    Ning, Keyang
    Gang, Yi
    STEEL AND COMPOSITE STRUCTURES, 2022, 42 (01): : 91 - 106
  • [29] Stability Behavior of Concrete-Filled Steel Tube Columns in Real Fire Conditions
    Taddhanpally, Shashank
    Agarwal, Anil
    STRUCTURES IN FIRE, 2016, : 527 - 534
  • [30] Nonlinear behavior of concrete-filled stainless steel stiffened slender tube columns
    Ellobody, Ehab
    THIN-WALLED STRUCTURES, 2007, 45 (03) : 259 - 273