摘要
Quantitative imaging of the human brain is of great interest in clinical research as it enables the identification of a range of MR biomarkers useful in diagnosis, treatment and prognosis of a wide spectrum of diseases. Here, a 3D two-point method for water content and relaxation time mapping is presented and compared to established gold standard methods. The method determines free water content, H2O, and the longitudinal relaxation time, T-1, quantitatively from a two-point fit to the signal equation including corrections of the transmit and receive fields. In addition, the effective transverse relaxation time, T-2*, is obtained from an exponential fit to the multi-echo signal train and its influence on H2O values is corrected. The phantom results obtained with the proposed method show good agreement for H2O and T-1 values with known and spectroscopically measured values, respectively. The method is compared in vivo to already established gold standard quantitative methods. For H2O and T-2* mapping, the 3D two-point results were compared to a measurement conducted with a multiple-echo GRE with long TR and T-1 is compared to results from a Look-Locker method, TAPIR. In vivo results show good overall agreement between the methods, but some systematic deviations are present. Besides an expected dependence of T-2* on voxel size, T-1 values are systematically larger in the 3D approach than those obtained with the gold standard method. This behaviour might be due to imperfect spoiling, influencing each method differently. Results for H2O differ due to differences in the saturation of cerebrospinal fluid and partial volume effects. In addition, ground truth values of in vivo studies are unknown, even when comparing to in vivo gold standard methods. A detailed region-of-interest analysis for H2O and T-1 matches well published literature values.
引用
收藏
页数:21
相关论文
共 44 条
  • [1] Whole-brain 3D mapping of human neural transplant innervation
    Jonas Doerr
    Martin Karl Schwarz
    Dirk Wiedermann
    Anke Leinhaas
    Alina Jakobs
    Florian Schloen
    Inna Schwarz
    Michael Diedenhofen
    Nils Christian Braun
    Philipp Koch
    Daniel A. Peterson
    Ulrich Kubitscheck
    Mathias Hoehn
    Oliver Brüstle
    Nature Communications, 8
  • [2] Whole-brain 3D mapping of human neural transplant innervation
    Doerr, Jonas
    Schwarz, Martin Karl
    Wiedermann, Dirk
    Leinhaas, Anke
    Jakobs, Alina
    Schloen, Florian
    Schwarz, Inna
    Diedenhofen, Michael
    Braun, Nils Christian
    Koch, Philipp
    Peterson, Daniel A.
    Kubitscheck, Ulrich
    Hoehn, Mathias
    Bruestle, Oliver
    NATURE COMMUNICATIONS, 2017, 8
  • [3] Comparison of Spline Methods for 3D Brain Mapping
    Piorecka, Vaclava
    Krajca, Vladimir
    Palenicek, Tomas
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2, 2019, 68 (02): : 421 - 423
  • [4] Deficient MWF mapping in multiple sclerosis using 3D whole-brain multi-component relaxation MRI
    Kitzler, Hagen H.
    Su, Jason
    Zeineh, Michael
    Harper-Little, Cynthia
    Leung, Andrew
    Krernenchutzky, Marcelo
    Deoni, Sean C.
    Rutt, Brian K.
    NEUROIMAGE, 2012, 59 (03) : 2670 - 2677
  • [5] Whole-brain 3D mapping of oxygen metabolism using constrained quantitative BOLD
    Lee, Hyunyeol
    Wehrli, Felix W.
    NEUROIMAGE, 2022, 250
  • [6] A whole-brain 3D myeloarchitectonic atlas: Mapping the Vogt-Vogt legacy to the cortical surface
    Foit, Niels A.
    Yung, Seles
    Lee, Hyo Min
    Bernasconi, Andrea
    Bernasconi, Neda
    Hong, Seok-Jun
    NEUROIMAGE, 2022, 263
  • [7] Whole-Brain Water Content Mapping Using Super-Resolution Reconstruction with MRI Acquisition in 3 Orthogonal Orientations
    Thomas, Dennis C.
    Oros-Peusquens, Ana-Maria
    Poot, Dirk
    Shah, N. Jon
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (05) : 2117 - 2130
  • [8] Comparison of 3D two-point Dixon and standard 2D dual-echo breath-hold sequences for detection and quantification of fat content in renal angiomyolipoma
    Rosenkrantz, Andrew B.
    Raj, Sean
    Babb, James S.
    Chandarana, Hersh
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (01) : 47 - 51
  • [9] Whole-Brain 3D Activation and Functional Connectivity Mapping in Mice using Transcranial Functional Ultrasound Imaging
    Bertolo, Adrien
    Nouhoum, Mohamed
    Cazzanelli, Silvia
    Ferrier, Jeremy
    Mariani, Jean-Charles
    Kliewer, Andrea
    Belliard, Benoit
    Osmanski, Bruno-Felix
    Deffieux, Thomas
    Pezet, Sophie
    Lenkei, Zsolt
    Tanter, Mickael
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (168):
  • [10] Fast method for longitudinal relaxation time and water content mapping of the human brain on a clinical MR scanner
    Kövér, F
    Schwarcz, A
    Pál, J
    Bogner, P
    Vajna, T
    Vadon, G
    Dóczi, T
    ACTA NEUROCHIRURGICA, 2004, 146 (12) : 1341 - 1346