Small-scale in vivo imaging of soft tissues by radioscopy using single X-ray photon counting

被引:7
|
作者
Hanus, Robert
Dammer, Jiri
Holy, Tomas
Jakubek, Jan
Pospisil, Stanislav
Tykva, Richard [1 ]
机构
[1] Acad Sci Czech Republ, Inst Organ Chem & Biochem, CZ-16610 Prague 6, Czech Republic
[2] Czech Tech Univ, Inst Expt & Appl Phys, CZ-12800 Prague 2, Czech Republic
关键词
in vivo imaging; termite soldier morphogenesis; X-ray radioscopy; 3D tomographic reconstruction;
D O I
10.1111/j.1365-2818.2007.01778.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
A method has been developed for routine laboratory visualisation of small-scale soft tissue by means of transmission X-ray radioscopy and tomography. Using termites as models, imaging quality with a spatial resolution of about 3 mu m was achieved and 3D tomographic reconstruction was demonstrated. A termite worker individual was visualized before and after its metamorphosis towards the soldier caste. The developed methodology represents a non-invasive and real-time way of acquiring 3D anatomic data with a high contrast so that it is a promising candidate to become a tool for routine investigations in life sciences.
引用
收藏
页码:191 / 194
页数:4
相关论文
共 50 条
  • [1] Single Photon Counting X-Ray Imaging System
    Lee, Seung Eun
    Kim, Sang Don
    COMPUTATIONAL INTELLIGENCE AND INTELLIGENT SYSTEMS, 2012, 316 : 617 - 620
  • [2] Small-scale fluctuations of the soft X-ray background
    Soltan, A
    Freyberg, MJ
    Trümper, J
    ASTRONOMY & ASTROPHYSICS, 2001, 378 (03) : 735 - 739
  • [3] Dose reduction using photon counting X-ray imaging
    Francke, T
    Eklund, M
    Ericsson, L
    Kristoffersson, T
    Peskov, V
    Rantanen, J
    Sokolov, S
    Söderman, J
    Ullberg, C
    Weber, N
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 127 - 132
  • [4] Optimal planar X-ray imaging soft tissue segmentation using a photon counting detector
    O'connell, J.
    Iniewski, K.
    Bazalova-Carter, M.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (01):
  • [5] Single photon counting x-ray imaging system using a Micro Hole and Strip Plate
    da Luz, Hugo Natal
    Oliveira, Carlos A. B.
    Azevedo, Carlos D. R.
    Mir, Jamil A.
    dos Santos, Joaquim M. F.
    Veloso, Joao F. C. A.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1661 - +
  • [6] Single-step phase contrast x-ray imaging using photon counting detectors
    Guersoy, Doga
    Das, Mini
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [7] Single Photon Counting X-Ray Imaging System Using a Micro Hole and Strip Plate
    da Luz, Hugo Natal
    Oliveira, Carlos A. B.
    Azevedo, Carlos D. R.
    Mir, Jamil A.
    de Oliveira, Rui
    dos Santos, Joaquim M. F.
    Veloso, Joao F. C. A.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (04) : 2341 - 2345
  • [8] X-ray Photon Counting and Two-Color X-ray Imaging Using Indirect Detection
    Dierickx, Bart
    Yao, Qiang
    Witvrouwen, Nick
    Uwaerts, Dirk
    Vandewiele, Stijn
    Gao, Peng
    SENSORS, 2016, 16 (06)
  • [9] Small-scale materials behavior from X-ray microdiffraction and imaging
    Rozaliya I. Barabash
    Gene E. Ice
    JOM, 2010, 62 : 21 - 21
  • [10] Beyond single photon counting X-ray detectors
    Bergamaschi, A.
    Dinapoli, R.
    Henrich, B.
    Johnson, I.
    Mozzanica, A.
    Shi, X.
    Schmitt, B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 628 (01): : 238 - 241