Experimental Comparison of Two Portable and Real-Time Size Distribution Analyzers for Nano/Submicron Aerosol Measurements

被引:15
|
作者
Hsiao, Ta-Chih [1 ]
Lee, Yao-Chuan [2 ]
Chen, Ke-Ching [1 ]
Ye, Wei-Cheng [1 ]
Sopajaree, Khajornsak [3 ]
Tsai, Ying I. [3 ,4 ]
机构
[1] Natl Cent Univ, Grad Inst Environm Engn, Taoyuan 32001, Taiwan
[2] Tungnan Univ, Dept Safety Hlth & Environm Engn, New Taipei 22202, Taiwan
[3] Chiang Mai Univ, Dept Environm Engn, Chiang Mai 50200, Thailand
[4] Chia Nan Univ Pharm & Sci, Dept Environm Engn & Sci, Tainan 71710, Taiwan
关键词
Portable aerosol mobility spectrometer; SMPS; Ultrafine particle; Aerosol measurement; Nanoparticle exposure; MOBILITY SPECTROMETER; ULTRAFINE PARTICLES; RESPIRATORY-TRACT; DEPOSITION;
D O I
10.4209/aaqr.2015.10.0614
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Two portable, battery powered particle size distribution analyzers, TSI NanoScan scanning mobility particle sizer (TSI NanoScan SMPS 3910, USA) and Kanomax Portable Aerosol Mobility Spectrometer (Kanomax PAMS 3300, Japan), have been recently introduced to the market. Both are compact and allow researchers to rapidly measure and monitor ambient or indoor ultrafine and nanoparticles in real time. In addition, both instruments apply the SMPS measuring scheme, utilizing a corona charger in place of a radioactive neutralizer, and are integrated with a hand-held condensation particle counter (CPC). In this study, the different designs, flow schemes, and operational settings of both instruments have been summarized based on the information released by the manufacturers and the available published literature. The performance characteristics and monitoring capability of these two portable ultrafine to nanoparticle sizers were investigated and compared to a reference TSI 3936 lab-based SMPS under identical conditions. Reasonable agreement was found between the three instruments in terms of their efficiency in sizing and counting polydispersed particles. Of the two portable analyzers, PAMS was able to provide a higher sizing resolution for monodispersed particle measurements than NanoScan, when operated under the High Mode (higher sheath to aerosol flow ratio).
引用
收藏
页码:919 / 929
页数:11
相关论文
共 50 条
  • [41] Real-time synchronous analysis for single aerosol based on polarization and fluorescence measurements
    Xu, Qizhi
    Song, Jiawei
    Zeng, Nan
    REAL-TIME PHOTONIC MEASUREMENTS, DATA MANAGEMENT, AND PROCESSING V, 2020, 11555
  • [42] Real-Time Distribution System State Estimation With Asynchronous Measurements
    Cavraro, Guido
    Comden, Joshua
    Dall'Anese, Emiliano
    Bernstein, Andrey
    IEEE TRANSACTIONS ON SMART GRID, 2022, 13 (05) : 3813 - 3822
  • [43] APPARATUS FOR REAL-TIME MEASUREMENT OF PARTICLE-SIZE DISTRIBUTION
    SADOWSKI, JW
    BYCKLING, E
    POWDER TECHNOLOGY, 1978, 20 (02) : 273 - 284
  • [44] Ambient measurements of biological aerosol particles near Killarney, Ireland: a comparison between real-time fluorescence and microscopy techniques
    Healy, D. A.
    Huffman, J. A.
    O'Connor, D. J.
    Poehlker, C.
    Poeschl, U.
    Sodeau, J. R.
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2014, 14 (15) : 8055 - 8069
  • [45] ZnO-modified glass capillaries as a portable photocatalytic reactor for real-time measurements
    Jayswal, Shefali
    Mohapatra, Saswat
    MATERIALS RESEARCH EXPRESS, 2024, 11 (09)
  • [46] A Portable System for Real-time Non-contact Blood Oxygen Saturation Measurements
    Mishra, Deepak
    Chandra, Shivam
    Chandra, Abhay
    Jain, Siddhant
    Sarkar, Mukul
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,
  • [47] MEASUREMENTS OF PARTICLE SIZE DISTRIBUTION OF ATMOSPHERIC AEROSOL .2. EXPERIMENTAL RESULTS AND DISCUSSION
    PASCERI, RE
    FRIEDLANDER, SK
    JOURNAL OF THE ATMOSPHERIC SCIENCES, 1965, 22 (05) : 577 - +
  • [48] MEASUREMENTS OF PARTICLE SIZE DISTRIBUTION OF ATMOSPHERIC AEROSOL .I. INTRODUCTION AND EXPERIMENTAL METHODS
    FRIEDLANDER, SK
    PASCERI, RE
    JOURNAL OF THE ATMOSPHERIC SCIENCES, 1965, 22 (05) : 571 - +
  • [49] Experimental measurements of distribution of retention time for aerosol particles through packed column
    Yang, TZ
    Chen, YL
    Xiong, W
    Yang, YQ
    Ma, J
    Ye, SY
    Liu, YN
    Yu, ZJ
    Song, T
    ACTA PHYSICO-CHIMICA SINICA, 2003, 19 (07) : 605 - 609
  • [50] Development and Validation of Effective Real-Time and Periodic Interinstrument Comparison Method for Automatic Hematology Analyzers
    Park, Sang Hyuk
    Park, Chan-Jeoung
    Kim, Mi-Jeong
    Choi, Mi-Ok
    Han, Min-Young
    Cho, Young-Uk
    Jang, Seongsoo
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2014, 142 (06) : 777 - 787