DURATION OF PRONE POSITIONING AFTER MACULAR HOLE SURGERY DETERMINED BY SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY

被引:15
|
作者
Sano, Masahiko [1 ]
Inoue, Makoto [1 ]
Itoh, Yuji [1 ]
Kita, Yoshiyuki [1 ]
Hirota, Kazunari [1 ]
Koto, Takashi [1 ]
Hirakata, Akito [1 ]
机构
[1] Kyorin Univ, Sch Med, Kyorin Eye Ctr, 6-20-2 Shinkawa, Mitaka, Tokyo 1818611, Japan
关键词
macular hole; optical coherence tomography; pars plana vitrectomy; swept-source optical coherence tomography; gas tamponade; RANDOMIZED CONTROLLED-TRIAL; FACE-DOWN; VITREOUS SURGERY; GAS TAMPONADE; VITRECTOMY; REPAIR; CLOSURE; EYES; AIR;
D O I
10.1097/IAE.0000000000001394
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the closure rate of macular hole closure and duration of the prone positioning after macular hole (MH) surgery with two protocols for halting the prone positioning. Methods: The authors studied 129 eyes of 125 consecutive patients with MH who had undergone vitrectomy. In 60 eyes of 59 patients, the prone positioning was halted after detecting an MH closure in the swept-source optical coherence tomographic images (SS group). In 69 eyes of 66 patients, the prone position was halted by the surgeon's decision (conventional group). The MH closure rate and duration of the prone positioning were compared. Results: Clear images of the MH were recorded in the SS group on postoperative Day 1 in 58 eyes (97%). In the SS group, MH closure was detected on postoperative Day 1 in 47 eyes (78%) and Day 2 in 4 eyes (7%). The MH was closed in 58 eyes (97%) in the SS group and 69 eyes (100%) in the conventional group (P = 0.21). None of the eyes had a reopening of the MH. The duration of prone positioning in the SS group was 1.8 +/- 2.5 days, which was significantly shorter than that in the conventional group at 8.4 +/- 4.2 days (P < 0.0001). Conclusion: The SS-OCT protocol can significantly decrease the duration of the prone positioning without a reopening of the MH.
引用
收藏
页码:1483 / 1491
页数:9
相关论文
共 50 条
  • [31] Utility of IOLMaster 700 Swept-Source Optical Coherence Tomography in Detecting Macular Disease for Preoperative Cataract Surgery Patients
    Ma, Jeffrey
    Pathak, Chintan
    Ramaprasad, Abhijit
    Basti, Surendra
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 3369 - 3378
  • [32] Detailed Corneal Characteristics with Swept-Source Optical Coherence Tomography in Patients with Macular Corneal Dystrophy
    Nowinska, Anna
    Teper, Slawomir
    Wylegala, Edward
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [33] Detecting macular disease with a biometry device using swept-source optical coherence tomography Reply
    Hirnschall, Nino
    Leisser, Christoph
    Radda, Stephan
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (10): : 1545 - 1545
  • [34] Macular retinal and choroidal thickness in unilateral amblyopia using swept-source optical coherence tomography
    Syunsuke Araki
    Atsushi Miki
    Katsutoshi Goto
    Tsutomu Yamashita
    Go Takizawa
    Kazuko Haruishi
    Yoshiaki Ieki
    Junichi Kiryu
    Kiyoshi Yaoeda
    BMC Ophthalmology, 17
  • [35] Macular Choroidal Thickness in Normal Pediatric Population Measured by Swept-Source Optical Coherence Tomography
    Ruiz-Moreno, Jose M.
    Flores-Moreno, Inaki
    Lugo, Francisco
    Ruiz-Medrano, Jorge
    Montero, Javier A.
    Akiba, Masahiro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (01) : 353 - 359
  • [36] Swept-source optical coherence tomography imaging of macular retinal and choroidal structures in healthy eyes
    Jiawei Wang
    Xinbo Gao
    Wenbin Huang
    Wei Wang
    Sida Chen
    Shaolin Du
    Xingyi Li
    Xiulan Zhang
    BMC Ophthalmology, 15
  • [37] Macular vessel density in diabetes and diabetic retinopathy with swept-source optical coherence tomography angiography
    Xie, Naiqiang
    Tan, Yan
    Liu, Sen
    Xie, Yining
    Shuai, Shaoshuai
    Wang, Wei
    Huang, Wenyong
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (12) : 2671 - 2679
  • [38] Macular choroidal thickness profile in healthy population measured by swept-source optical coherence tomography
    Moreno, J. M. Ruiz
    Ruiz-Medrano, J.
    Flores-Moreno, I.
    Pena-Garcia, P.
    Montero, J. A.
    ACTA OPHTHALMOLOGICA, 2013, 91
  • [39] Assessment of macular microcirculation in patients with multiple sclerosis by swept-source optical coherence tomography angiography
    Eker, Serhat
    Karakucuk, Yalcin
    Gumus, Haluk
    MARMARA MEDICAL JOURNAL, 2024, 37 (02): : 192 - 197
  • [40] Macular Choroidal Thickness and Volume in Normal Subjects Measured by Swept-Source Optical Coherence Tomography
    Hirata, Masaya
    Tsujikawa, Akitaka
    Matsumoto, Akiko
    Hangai, Masanori
    Ooto, Sotaro
    Yamashiro, Kenji
    Akiba, Masahiro
    Yoshimura, Nagahisa
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (08) : 4971 - 4978