Reduction of metal artifacts using subtracted CT projection data

被引:1
|
作者
Tolakanahalli, R [1 ]
Medow, JE [1 ]
Hsieh, J [1 ]
Chen, GH [1 ]
Mistretta, CA [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53704 USA
来源
关键词
CTA; DSA; metal artifacts;
D O I
10.1117/12.560037
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Metal artifacts in many cases significantly limit non-invasive imaging in evaluation of cerebrovascular patients who have undergone prior aneurysm clipping or coiling. The data inconsistency due to the presence of metal produces streaks in the reconstructed CT slices, which then manifest themselves in the coronal and sagittal reprojections most often used to display CT angiographic data. In DSA, no CT reconstructions are performed and the presence of metal only produces a reduction in SNR behind the metal unless misregistration produces artifacts. In this paper, we have begun to investigate a new method to obtain DSA-like images by using a CT scanner. In this approach, sinogram data is obtained from the multi-slice scanner using the same scan parameters before and after contrast injection. These sets of data are registered, subtracted and rebinned to generate radiography-like images. This new method to form DSA-like images from a CT scanner is called Digital Subtraction Topography (DST). Importantly, CT image reconstruction procedure is not performed to obtain DST images. In principle, the disturbing metal artifacts in the CT images do not appear in the DST images. A number of topographic images representing each of the gantry angles are obtained. These images give clinical information at all angles with AP and RL resolution equivalent to that in the CT slices. Resolution in the SI direction is determined by the CT slice thickness, which can be sub millimeter. The conventional CT image reconstruction can also be applied to DST datasets to generate CT DSA images. In the absence of misregistration, the metal artifacts in the reconstructed CT DSA images could be reduced.
引用
收藏
页码:636 / 643
页数:8
相关论文
共 50 条
  • [41] Reducing image artifacts in sparse projection CT using conditional generative adversarial networks
    Usui, Keisuke
    Kamiyama, Sae
    Arita, Akihiro
    Ogawa, Koichi
    Sakamoto, Hajime
    Sakano, Yasuaki
    Kyogoku, Shinsuke
    Daida, Hiroyuki
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [42] Reduction of the streak artifacts in circular cone beam CT using scanograms
    Zou, Yu
    Zamyatin, Alexander A.
    Chiang, Beshan S.
    Silver, Michael D.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3531 - 3536
  • [43] Reduction of aliasing artifacts in cone-beam CT images using data derivatives with respect to detector coordinates
    Zou, Y
    Pan, X
    Jiang, T
    MEDICAL PHYSICS, 2004, 31 (06) : 1820 - 1820
  • [44] Virtual Monochromatic Spectral Imaging with Fast Kilovoltage Switching: Reduction of Metal Artifacts at CT
    Pessis, Eric
    Campagna, Raphael
    Sverzut, Jean-Michel
    Bach, Fabienne
    Rodallec, Mathieu
    Guerini, Henri
    Feydy, Antoine
    Drape, Jean-Luc
    RADIOGRAPHICS, 2013, 33 (02) : 573 - 583
  • [45] Influence of Metal Artifacts Reduction Algorithm (MAR) on CT Number (Hounsfield Unit) Accuracy
    Holla, R.
    Khanna, D.
    Naik, V.
    Pillai, B.
    MEDICAL PHYSICS, 2018, 45 (06) : E216 - E216
  • [46] Suppression of metal streak artifacts in CT using a MAP reconstruction procedure
    Lemmens, Catherine
    Faul, David
    Hamill, James
    Stroobants, Sigrid
    Nuyts, Johan
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3431 - 3437
  • [47] Reduction of beam hardening induced metal artifacts using consistency conditions
    Abdurahman, Shiras
    Frysch, Robert
    Rose, Georg
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [48] Fast Enhanced CT Metal Artifact Reduction Using Data Domain Deep Learning
    Ghani, Muhammad Usman
    Karl, W. Clem
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2020, 6 : 181 - 193
  • [49] Metal implants on CT: comparison of iterative reconstruction algorithms for reduction of metal artifacts with single energy and spectral CT scanning in a phantom model
    Fang, Jieming
    Zhang, Da
    Wilcox, Carol
    Heidinger, Benedikt
    Raptopoulos, Vassilios
    Brook, Alexander
    Brook, Olga R.
    ABDOMINAL RADIOLOGY, 2017, 42 (03) : 742 - 748
  • [50] Metal implants on CT: comparison of iterative reconstruction algorithms for reduction of metal artifacts with single energy and spectral CT scanning in a phantom model
    Jieming Fang
    Da Zhang
    Carol Wilcox
    Benedikt Heidinger
    Vassilios Raptopoulos
    Alexander Brook
    Olga R. Brook
    Abdominal Radiology, 2017, 42 : 742 - 748